Model 10 Series - Pressure Switch - Brochure

GENERALBEFORE INSTALLING, CHECK THE SENSOR MODEL SELECTED FOR COMPATIBILITY TO THE PROCESS MEDIA IN CONTACT WITH THE SENSOR AND WETTED PARTS.The Spectra-10 pressure switch utilizes a diaphragm or piston sensor to detect a pressure change. The response, at a predetermined set point, actuates a SPDT snap-acting switch, converting a pressure signal into an electrical signal. Control set point may be varied by turning the internal slotted adjustment screw bushing (see Part II - Adjustments).PROOF PRESSURE* LIMITS STATED IN THE LITERATURE AND ON NAMEPLATES MUST NEVER BE EXCEEDED, EVEN BY SURGES IN THE SYSTEM. OCCASIONAL OPERATION OF UNIT UP TO PROOF PRESSURE IS ACCEPTABLE (E.G., START-UP, TESTING). CONTINUOUS OPERATION SHOULD NOT EXCEED THE DESIGNATED OVER RANGE PRESSURE.***Proof PressureThe maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage (e.g., start-up, testing). **Over Range PressureThe maximum pressure to which a pressure sensor may be continuously subjected without causing damage and maintaining set point repreatability.THESE PRODUCTS DO NOT HAVE ANY FIELD REPLACEABLE PARTS.Please refer to product bulletin for product specifications. Product bulletin may be found at www.ueonline.comTools Needed1-1/16" Open end wrenchScrewdriver (option M449 only)for customer- supplied mounting screwMouNTiNGALWAYS LOCATE UNITS WHERE SHOCK, VIBRATION AND AMBIENT TEMPERATURE FLUCTUATIONS ARE MINIMAL. DO NOT MOUNT IN AMBIENT TEMPERATURE AREAS EXCEEDING 160° F (WITH BUNA N CONSTRUCTION) OR 180°F (WITH VITON CONSTRUCTION). IF SEVERE PRESSURE SURGES ARE EXPECTED, CONSIDER THE USE OF A PRESSURE SNUBBER.UNIT MAY BE MOUNTED IN ANY POSITION. ALWAYS USE A WRENCH ON PRES-SURE CONNECTION WRENCH FLATS. IF UNIT IS TO BE SET AFTER MOUNTING, RAISE ADjUSTMENT COVER, THEN THREAD IN PRESSURE CONNECTION UNTIL SNUG. VERIFY THAT ADjUSTMENT OPENING IS ACCESSIBLE.IF INSTALLATION LOCATION RESULTS IN FREqUENT EXPOSURE TO LIqUID, IT IS RECOMMENDED THAT THE UNIT BE MOUNTED VERTICALLY WITH THE PRESSURE CONNECTION DOWN. Panel mounting via 1/2" NPT (male) Electrical Connection (termination type C)Mount through 7/8" clearance hole in panel. Hold in place with serrated 1/2" conduit nut. Always support the unit by holding a wrench on the 11/16" hex nearest the conduit connec-tion.Optional Surface Mounting Bracket (option M449)The surface mounting bracket is a “C” style clamp with a single clearance hole to accommodate a 1/4" screw (see Figure 1). Insert the unit into the bracket, pressure connection end first. Open the adjustment cover and mount the unit so that adjustment opening will be accessible when the switch is mounted. Close the adjustment cover ensuring that the bracket does not interfere with the cover. Failure to do so may result in improper sealing of adjustment cover. Mount assembly in desired location. iM10-09Spectra 10 Series Pressure SwitchPlease read all instructional literature carefully and thoroughly before starting. Refer to the final page for the listing of Recommended Practices, Liabilities and Warranties.Part i - installationWiRiNGDISCONNECT ALL SUPPLY CIRCUITS BEFORE WIRING UNIT. ELECTRI-CAL RATINGS STATED IN LITERATURE AND NAMEPLATES MUST NOT BE EXCEEDED. OVERLOAD ON A SWITCH CAN CAUSE FAILURE ON THE FIRST CYCLE.WIRE IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES. Termination Type A, 0.11" push-on terminals Unit is supplied with male and female terminals. Insert 18-22 AWG stripped leadwire into female terminal and crimp using appropriate hand tool. Refer to molded-in N.O., N.C., and COM designations for proper wiring.Termination Type B, 0.25" push-on terminalsN.O., N.C., and COM terminals require 1/4” female push-on terminals. Insulated female terminals are recommended for safety. Use non-conductive protective grease for corrosion resistance in outdoor use.Termination Type C & D, 18" leads 18 AWG Color coding: Terminals Color N.O. Blue N.C. Black Com Violet TO ATTACH TYPE C TO CONDUIT CONNECTION, HOLD ELECTRICAL CONNEC-TION STEADY WITH WRENCH ON HEX, THEN THREAD ON CONDUIT.Termination Type E & G, with 5’ cordCut cord to desired length (if necessary). Strip back insulation. Color coding: Terminals Color N.O. Red N.C. Black Com WhiteTO ATTACH TYPE E TO CONDUIT CONNECTION, HOLD ELECTRICAL CONNEC-TION STEADY WITH WRENCH ON HEX, THEN THREAD IN CONDUIT.Termination Type F, DIN Connector with 4 Male Terminals Connector conforms to DIN 43650, Form A. Use a mating DIN connector (female type, not UE supplied). Terminal coding: Terminals Terminal #1 Common Terminal #2 Normally Closed Terminal #3 Normally Open Terminal #4 Not used installation and Maintenance instructionsU N I T E D E L E C T R I C C O N T R O L SIM10-09 Figure 1OPTION M449CP081115KTools NeededFlat Blade Screwdriver1. Connect control to an adjustable pressure source.2. With power disconnected, slide cover toward electrical terminations while twist-ing it to overcome friction.3. Connect power to terminals or leads.4. Insert screwdriver into adjustment slot and turn clockwise (left) to increase setting or counter clockwise (right) to decrease setting.For setting on rise, apply desired pressure and turn adjustment clockwise (left) until switch actuates (circuit across N.O. and COM terminals closes). For setting on fall, apply pressure equal to normal system operating pressure. Reduce source pres-sure to setpoint value. Turn adjustment counter clockwise (right) until switch actu-ates (circuit across N.C. and COM closes).5. After completing adjustments, slide cover closed over adjustment compart-ment. Recheck set point.Part ii - Adjustments DimensionsRECOMMENDED PRACTICES AND WARNINGS United Electric Controls Company recommends careful consideration of the following factors when specifying and installing UE pressure and temper-ature units. Before installing a unit, the Installation and Maintenance instruc-tions provided with unit must be read and understood. • To avoid damaging unit, proof pressure and maximum temperature limits stated in literature and on nameplates must never be exceeded, even by surg-es in the system. Operation of the unit up to maximum pressure or tempera-ture is acceptable on a limited basis (e.g., start-up, testing) but continuous operation must be restricted to the designated adjustable range. Excessive cycling at maximum pressure or temperature limits could reduce sensor life.• A back-up unit is necessary for applications where damage to a primary unit could endanger life, limb or property. A high or low limit switch is nec-essary for applications where a dangerous runaway condition could result.• The adjustable range must be selected so that incorrect, inadvertent or ma-licious setting at any range point cannot result in an unsafe system condi-tion. • Install unit where shock, vibration and ambient temperature fluctuations will not damage unit or affect operation. Orient unit so that moisture does not enter the enclosure via the electrical connection. When appropriate, this entry point should be sealed to prevent moisture entry.• Unit must not be altered or modified after shipment. Consult UE if modifi-cation is necessary. • Monitor operation to observe warning signs of possible damage to unit, such as drift in set point or faulty display. Check unit immediately.• Preventative maintenance and periodic testing is necessary for critical ap-plications where damage could endanger property or personnel.• For all applications, a factory set unit should be tested before use.• Electrical ratings stated in literature and on nameplate must not be ex-ceeded. Overload on a switch can cause damage, even on the first cycle. Wire unit according to local and national electrical codes, using wire size recommended in installation sheet.• Do not mount unit in ambient temp. exceeding published limits.LIMITED WARRANTYSeller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period of 24 months from the date of manufacture by the Seller. Seller shall not be obligated under this warranty for alleged defects which examina-tion discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller’s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. LIMITATION OF SELLER’S LIAbILITYSeller’s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the “limited warranty” of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party.UE specifications subject to change without notice.Type 10-A “A”“B”Type 10-D “A”“B”Type 10-G “A”“B”Type 10-F “A”“B”180 Dexter Avenue, P.O. Box 9143Watertown, MA 02471-9143 USATelephone: 617 926-1000 Fax: 617 926-2568http://www.ueonline.comU N I T E D E L E C T R I C C O N T R O L SIM10-09 “A”“B”Type 10-EType 10-B “A”“B”Dimension A bModels Inches mm NPTA10-12 3.00 76.2 1/8"A13-16 3.31 84.1 1/4"B10-12 3.50 88.9 1/8"B13-16 3.81 96.8 1/4"C10-12 4.06 103.2 1/8"C13-16 4.38 111.1 1/4"D10-12 3.19 81.0 1/8"D13-16 3.50 88.9 1/4"E10-12 3.94 100.0 1/8"E13-16 4.25 108.0 1/4"F10-12 4.13 104.8 1/8"F13-16 4.44 112.7 1/4"G10-12 3.88 98.4 1/8"G13-16 4.19 106.4 1/4"Type 10-C “A”“B”
Most popular related searches