Thermo Scientific - Air Quality Instruments

Model 146i Data Sheet (PDF 105 KB)

Product SpecificationsModel 146i Multi-gas CalibratorMass flow calibrator with enhanced communication capabilities for ambient air monitoring. A change is in the airThe Thermo Electron Model 146i Dynamic Gas Calibrator supplies precise levels of ozone, carbon monoxide, non-methane hydrocarbons, sulfur dioxide, nitric oxide and nitrogen dioxide or other gases that a user may require. The gas levels are used to calibrate instruments that perform zero, precision and level 1 span checks, audits and multipoint measurements. The design of the Model 146i meets or exceeds all published U.S. Environmental Protection Agency requirements for multipoint cali-bration, audit, Level 1 and 2 span and pre-cision checks. Options include Gas Phase Titration, UV Photometer, and Permeation OvenThe Model 146i’s mass flow controller, ozone generator, permeation tube oven, power supply, and solenoid valves are integrated into a single microprocessor controlled unit. This permits easy to use, menu driven software and a consistent set of operation screens for all calibration procedures. Additionally, the micropro-cessor can make many of the necessary calculations, thereby freeing the operator from having to make the calculations in the field or laboratory. If desired, the Model 146i can be operated remotely by a data logger or to perform multipoint calibrations.Key Features ? Ethernet connectivity for efficient remote access? Enhanced user interface with one button programming and large display screen? Flash memory for increased data storage and user downloadable software? Enhanced electronics design optimizes product commonality? Improved layout for easier accessibility to components? Gas Phase Titration for Generation of O3 and NO2This specification sheet is for informational purposes only and is subject to change without notice. Thermo makes no warranties, expressed or implied, in this product summary. © 2006 Thermo Fisher Scientific. All rights reserved. Lit _146iEID_1/07Product SpecificationsComprehensive Service SolutionsTo maintain optimal product performance, you need immediate access to experts worldwide, as well as priority status when your air quality equipment needs repair or replacement. Thermo Scientific offers comprehensive, flexible support solutions for all phases of the product lifecycle. Through predictable, fixed-cost pricing, Thermo Scientific services help protect the return on investment and total cost of ownership of your Thermo Scientific air quality products.Model 146i Calibrator Choose from the following configurations/optionsto customize your own Model 146iVoltage options:A = 120 Vac 50/60 Hz (standard)B = 220 Vac 50/60 HzJ = 100 Vac 50/60 HzCalibration Sources N = No Optional Calibration Sources (standard) P = Internal Permeation Span Source T = Gas Phase TitrationB = Gas Phase Titration with Photometer C = Internal Permeation Span Source with Gas Phase TitrationD = Internal Permeation Span Source with Gas Phase Titration and Photometer Span Ports3 = Three Span Inputs (standard) 6 = Six Span Inputs Span Gas Mass Flow Controller A = 50 SCCM B = 100 SCCM (standard) C = 200 SCCM Zero Gas Mass Flow ControllerD = 5 SLPM E = 10 SLPM (standard) F = 20 SLPM Optional I/O:A = None (standard)C = I/O expansion board (4-20mA outputs - 6 channels, 0-10v inputs - 8 channels)Mounting Hardware:A = Bench mounting (standard)B = Ears & handles, EIAC = Ears & handles, RetrofitOrdering Information Your Order Code: 146i - __ __ __ __ __ __ __Other options:? Rack mounts ? Cable, DB37M to open end, 6' LG.? Rear extender ? Cable, DB37F to open end, 6' LG.? Terminal Block Kit & Cable 37 pin ? Terminal Block Kit & Cable 25 pin ? Cable, DB25M to open end, 6' LG. ? Cable, RS232 Null Modem Dilution SystemFlow Measurement Accuracy +/- 2% setpoint or +/- 1% FS, whichever is less from 20 to 100% FSRepeatability of flow control +/- 0.2% FS (Porter flow controller spec - better than 146C)Linearity of mass flow measurements +/- 0.5% FSFlow range of dilution air 0-10 SLPM optional ranges 0-5/0-20 SLPMFlow range of cylinder gases 0-100SCCM optional ranges 0-50/0-200 SCCMZero Air requirements 10 SLPM @ 30 PSI optional ranges 20 SLPM @ 30 PSICalibration gas input ports 3, optional 6Diluent gas input ports 1Response time <60 sec. To 99% (146C spec)Ozone Generator OptionMaximum output 1 ppm @ 6 SLPMMinimum output 10 ppb @ 6 SLPMPhotometer SystemFull Scale Range 100 ppb to 5 ppm user selectableLinearity 1% of Full ScalePrecision 1 ppbResponse Time 180 Seconds to 95% of TargetMinimum Detectable Limit 3 ppbPhysical SpecificationsTest channel analog 6 @ +/- 100 mv, 1,5,10 volts (user selectable)Digital control outputs 10 Relay and 8 24vdc SolenoidDigital control inputs 16 Temperature range 0-40 deg C Weight 51 lbs (58 lbs for 220-240VAC)Dimensions 16.75” W x 8.62” H x 23” DPower 100VAC 50/60Hz, 115VAC 50/60Hz, 220-240VAC 50/60Hz, 275 watts (with all options)Environmental InstrumentsAir Quality Instruments27 Forge Parkway Franklin, MA 02038 USATakkebijsters 1Breda, BL 4817The Netherlands+1 (866) 282-0430+1 (508) 520-1460 fax+31 (0) 76 5879888+31 (0) 76 5816520 faxwww.thermo.com/air
Most popular related searches