Pres Block S.P.A.
- Home
- Companies & Suppliers
- Pres Block S.P.A.
- Downloads
- Model 2,6 l/min and P/N ITRGMD026FLM - ...
Model 2,6 l/min and P/N ITRGMD026FLM - Standard Flow-Meters - Datasheet
Performances: Fluids accepted: water, glycol solutions, % glycol max: 50%, Working temperature: 5÷55 °C, Max temperature: 90 °C at 3 bar, Working pressure: 0÷6 bar, Max pressure: 10 bar, Burst pressure: > 22 bar at room temperature > 15 bar at 50 °C, Flow-rate range: 0÷2,6 l/min, Deviation percentage: + 15%, Max torque to adjust the flow-rate: 1 N-m (please use the proper adjusting key), Torque to lock the flowmeter to the manifold: Max 5 N-m, Suggested glue to lock the flowmeter: Loctite 5331.