Rudolph Research Analytical
- Home
- Companies & Suppliers
- Rudolph Research Analytical
- Downloads
- Model DDM 2910 - Digital Density Meter ...
Model DDM 2910 - Digital Density Meter Brochure
TECHNICAL BULLETIN 935For High Accuracy ApplicationsThe DDM Series ofAutomatic Density MetersFor High Accuracy ApplicationsThe DDM Series ofAutomatic Density MetersDDM 2910 DDM 2911 DDM 2911 PLUSAccuracy Density: 0.0001 g/cm3 Temperature: 0.05 °CDensity: 0.00005 g/cm3 Temperature: 0.03 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CRepeatability Density: 0.00005 g/cm3 Temperature: 0.02 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CDensity: 0.000005 g/cm3 Temperature Selectable: 0.001 °CResolution Density: 0.0001 g/cm3 Temperature: 0.01 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CDensity: 0.000001 g/cm3 Temperature Selectable to: 0.001°CDensity Ranges 0 to 3 g/cm3 Temperature Range 0 °C to 95°C (controlled via Peltier) Pressure 0 to 10 barsVideo Scanning & MagnificationThree magnified video assisted views of the entire cell are available, in 2x, 6x and a 10x magnifications with video scanning. Images maybe saved with results for subsequent review.Automatic Bubble DetectionAutomatically warns operator of bubblesMeasurement Modes Continuous, Single, MultipleMeasurement Technique Mechanical Oscillating U-Tube MethodMinimum Sample Volume Less than 1mLWetted Materials Borosilicate glass, Teflon PTFE ECTFEOperating Systems Windows 7® Embedded; write protected software safe from maleware and virusesMeasurement Time: 30 - 60 seconds after thermal equilibrationDisplay 10.4 inch diagonal TFT type LCD with wide viewing angle, anti-glare flat panel touch screen, 300 nits brightness, 800 x 600 pixels, chemical, scratch and spill resistant monitor, the industry’s largest and most flexible interfaceCommunication InterfaceTouch Screen User Interface, 5 – USB Ports, 2 – RS232 Ports, Ethernet Port for Network Connection, Keyboard Bar Code Scanner, Mouse, Network CapabilitiesRemote Support Touble shooting, Diagnostics, Software Updates available via the InternetInternal Memory 8 GB Non-removable Compact FlashOperating Dimensions 18.36” (L) x 11.80” (W) x 13.90” (H) 46.61 cm (L) x 29.97 cm (W) x 35.30 cm (H)Shipping Dimensions and Weight24.5” (L) x 17.5” (W) x 22” (H) 62cm (L) x 44cm (W) x 56cm (H)Shipping Weight 50 lbs. (23kg)Power Supply 85 to 260 VAC; 48 to 62 HzPower Consumption 140 Watts at peakOrigin of Manufacture and DesignUSA• Three magnified video assisted views of the entire cell are available, in 2x, 6x and a 10x magnifications• Images maybe saved with results for subsequent review• Automatic Bubble detection is available which will flag the sample(s) with suspected bubblesFull Feature VideoView™ with Automatic Scanning of Entire U-TubeRudolph’s exclusive VideoView is protected under Patent #7,437,909 and provides superior high resolution visual bubble detection within your sample with live on-screen video viewing. Images can be saved with the sample results and may be viewed and or printed as desired.A full view of the entire U-tube is possible at 2x magnification without any obstruction. Further, the U-Tube can be scanned at 6x or 10x magnification so the user can see that the U-Tube is bubble free. The 10X magnification is also extremely helpful in detecting the cleanliness of the glass U-tube. The clarity, magnification and resolution are the very best available. Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comThe Simplicity of Touch Screen Measurement with the Flexibility of Windows® 7• 8 gigabytes of internal memory allows almost unlimited capacity for saving measurement data. All Rudolph DDM Series Density meters are network ready and data may also be saved directly to your server or to any desired directories• Internet access is possible directly from all Rudolph DDM Density meters touch screen. The disk protection feature protects the operating system against malware infections in networked environments• Windows based navigation architecture is so intuitive that most operators will never read the manual, but should you wish to reference the manual, it is stored right on the Rudolph DDM’s internal memory• Copy methods, transfer concentration tables, download data, etc., via the USB ports on the front and back of the unit• Five USB ports allow for quick and easy connection to a mouse, keyboard, printer, bar code scanner, or memory stick. Embedded Windows 7 prevents any and all viruses and malwareDensityDensity Meter 24-May-201212:05:40 HELPSpecific GravityMethod InformationSampleMethodMeasurement ModeMeasurement CriteriaNormalityHydrochloric AcidBaumeMENU METHOD PRINT EXPORT AIR PUMP ACCESSORIESHClMultiple [5]RAPIDSample IDLot IDTemperature (Deg C) HeatedInterfaceSetSampleSTARTVIDEO20.0020.00 OFFExport SettingsExport DataData LocationFile Naming OptionUser Defined FileNameFile TypesDelimiterFIELD SETTINGS SAVE SAVEAUTO EXPORT SETTINGSYesUser DefinedResults ExpCSVComma Overwrite fileAppend to fileBrowse For FolderSelect a directory to store the resultX?Make New Folder OK CancelMy ComputerLocal Disk (C)HP v125w (D)densitymeter on ‘172.27.32.135’ (P:)densitymeter on ‘172.27.32.163’ (Q:)densitymeter on ‘172.27.32.151’ (R:)Control PanelShared Documents+++++++USB Thumb DriveBarcode ScannerComputer Windows 7 Embedded Based FlexibilityRudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comOscillating U-Tube with Viscosity Correction and Reference OscillatorRudolph DDM Density meters utilize an oscillating U-tube with full range viscosity correction and reference oscillator that allows for long term calibration stability and measurement at all temperatures with a single calibration. (Patent # 7,735,353)Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comThe Simplicity of Touch Screen Measurement with the Flexibility of Windows® 7cGMP/GLP Calibration• Calibrate the Rudolph DDM Density Meter with 2 or 3 NIST Traceable Standards – calibrating with merely air and water appears inconsistent with cGMP/GLP compliance regulations• Can print out complete method configuration, communication settings, as well as calibration verification and calibration adjustment data/history• Measured values can be shown continuously as temperature stability is being reached or, at the discretion of the user, measured values will only be displayed once the measurment is complete • Unlimited number of customizable calibration adjustments and calibration verifications possible• Complete History of Calibration Adjustments and Verifications are available to View, Print, and/or Export• Set calendar reminders as to when Calibration Verifications are dueDensityDensity Meter 24-May-201212:05:40 HELPSpecific GravityMethod InformationSampleMethodMeasurement ModeMeasurement CriteriaNormalityHydrochloric AcidBaumeMENU METHOD PRINT EXPORT AIR PUMP ACCESSORIESHClMultiple [5]RAPIDSample IDLot IDTemperature (Deg C) HeatedInterfaceSetSampleSTARTVIDEO20.0020.00 OFFCalibration AdjustmentAvailable Calibration AdjustmentsAir, WaterAir, Water and 3rd PointTemperatureViscosityBarometric PressurePERFORMSETTINGSHISTORYCLOSECalibration VerificationCalibration Verifications ListWater at 25CWater at 20CNIST Toluene StandardPERFORMADDEDITDELETEHISTORYCLOSERudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comVersatility, Traceability, Compliance and FlexibilityPrint your customized Certificate of Analysis including your company logo directly from the DDM Density Meter touch screenCapable of making multiple measurements on a single sample and reporting complete statistical data and all measurement resultsVersatile Communication Capability The Rudolph DDM Density Meter’s standard communication package includes:• CAT 5 Ethernet Port for Network Cable Connection• 5 USB ports• 1 RS 232 portsAllowing the capability to: • Export measurement results with saved video view images to a thumb drive, store it locally on the C:\\ drive, or easily send data to any external PC, LIMS, SAP, etc• Print measurement results to any local or networked printer. Most all printers are supported by Windows 7® but if required the driver may be added• Save measurement data direct to your Network/ServercGMP/GLP PrintingSample measurement reports are edited quickly and easily. Just import your logo to the Rudolph DDM Density Meter and send your company’s customized certificate of analysis to your server or local printer.1-40, Goryo Ohara, Nishikyo-ku, Kyoto 615-8245, JapanTel: +81-75-382-1411 Date: February 19, 2014This sample was measured on DDM 2911 PLUS serial number 20212, manufactured by Rudolph Research Analytical, Hackettstown, NJ, USA.Lot ID 2019Temperature: 20.0 Deg CNo Sample ID Density Sp. Gravity Normality HCL % wt ° Baume Time1 8421 1.09803 1.1000 6.0092 19.95 12.94 14:20:50 PM1 8421 1.09803 1.1000 6.0092 19.95 12.94 14:21:40 PM1 8421 1.09803 1.1000 6.0092 19.95 12.94 14:22:30 PM1 8421 1.09803 1.1000 6.0092 19.95 12.94 14:23:20 PM1 8421 1.09803 1.1000 6.0092 19.95 12.94 14:24:10 PMCounts : 5Average : 1.0980SD : 0.0000Maximum : 1.0980Minimum : 1.0980Operator : ___________________________Flexible Method Management Factory installed measurement methods allow for immediate selection of the correct method to match the most common applications.For unique measurement applications, easily create a sample method using an unlimited number of Concentration Tables, Formulas, and Polynomials to match the measurement methods used in your laboratory.AOAC EthanolBrixCrude OilDensityDensity ContinuousDensity through TemperatureDensity VCFactory QC TestingFuel OilLubricantsOIML EthanolNAMEFactoryFactoryFactoryFactoryFactoryFactoryFactoryFactoryFactoryFactoryFactoryTYPEMethod ManagementADDCOPYHIDERENAMEVIEWRESULTSMETHODCONFIGURATIONCLOSE• Concentration D2O – Heavy Water • Proofing of Ethanol Sample • Density of Gasses • Testing of aspartame and other artificial sweeteners• Monomer Solutions • Hydrogen Peroxide • Determination of Partial Specific Volume • ppm, Normality, Molarity • % Toluene in Heptane• Mole Fraction of Methanol• Purity of sample testing• Density of Gasses and Aerosols• Potassium Permanganate • Sweeteners• Ultracentrifugation applications• SG of Urine• Sodium HydroxideCustomized Methods:Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comVersatility, Traceability, Compliance and FlexibilityNIST Traceable Calibration StandardsRudolph knows how important it is to calibrate with Traceable Standards and therefore, we include either a NIST or UKAS standard in the accessories provided with your density meter. The Rudolph DDM Density Meters includes all the accessories for immediate use which includes:• Quick Start Guide• IQOQPQ Documentation• Rinse/Sample Waste Container• Filling Nozzles• Connecting Fittings & TubingFull 21CFR Part 11 Instrument Level ComplianceThe The Rudolph DDM Density Meter’s 21CFR Part 11 software module is easily enabled through the user friendly touch screen. This module gives you full compliance with: • Electronic signature• Access levels• Internal write protected storage • Unique passwords• Write protected documents sent directly to server• Traceable Standard• Luer Syringes• User Manual• Tools• Audit Trail• PDF Meta DataRudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.com Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.com The DDM Series of density meters can be combined with various Rudolph Automation Systems and Sample Handling Accessories. Available are Peristaltic Pumping, Heated Sampler, the ECS (Easy Clean System), and the Rudolph R837 AutoFlex Sampler. The Rudolph Research R837 AutoFlex is perfect for high throughput laboratories looking to increase productivityThe R837 AutoFlex Sampler Facilitates: • Customizable bottle size, Test Tube size, Boston Rounds:1oz, ½ oz, virtually any size• Customizable Rack configurations: heated and unheated on the same carousel • Automated sample introduction• Flexible Method Selection: Suction mode, Pressure mode, Rinse and Dry Duration• Programmable cleaning and drying• Automatic solvent and waste level detection• System Configuration minimal sample volume: 1.5 mL• A heated interface is available• Fast throughput, 2-5 min complete cycle time• Automation saves operator time and increases your lab’s efficiency • An urgent-sample interruption can be made at any timeOperation is completely automatic. The sample is measured and the data recorded. Depending on how the system is configured the data may also be printed, saved as an Excel file or transferred to a LIMS system.Automation SolutionsAutomate your Laboratory with a Rudolph AutoFlex R837 Automation System50ml of Sample Waste Container With Over Fill WarningPeristalic Pump OptionRinse & SolventSyringe Pump and Air PumpRefractometer Measurement ModuleMetal Sipper noseFlow through Configuration with ECS: Density Meter, Refractometer Optics Module and a Rudolph (ECS) Easy Clean sampling SystemDescriptionThis configuration is the most versatile. The user loads the sample in a similar way to the peristaltic pump system but after the measurement; the instrument disposes of the sample to waste, rinses with two solvents and then dries with air from the built in pump. Who should consider this system? • Users who want the ease of automated loading and cleaning• Users with samples that have too high a viscosity to be pumped with a peristaltic pump• Users who have a significant amount of samples but not enough to require full automation Rudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.comDDM 2911 PLUS Density Meter is a Rudolph Research’s TTB Approved Instrument for Alcohol Proof Testing. DensitometryPETROLEUM, CHEMICAL• Measure API, Density and Specific Gravity values in accordance with ASTM D1250, ASTM D4052, ASTM D4806, ASTM D5002, ASTM D5931, ISO 12185 and DIN 51757• Measure in units of Kg/m3, g/cm3, g/mL, pounds/gallon, specific gravity, Baumé and more • Check batch consistency and ensure proper blending ratios• Withstands harsh environments and aggressive chemicals• Calibrate using petroleum standardsBEVERAGES, SPIRITS, WINE• The US Alcohol and Tobacco Tax and Trade Bureau (TTB) requires 0.02% Ethanol accuracy for testing of % Ethanol in wine, beer, and spirits for the purposes of taxation and labeling• The DDM2911 Plus offers 0.01% accuracy for Ethanol testing• Direct and accurate means of °Brix determination, °Plato, °Balling, Proof, % SolidsThe Rudolph DDM series of density meters, with high precision Peltier temperature control of sample, has the features to meet the needs of today’s industrial applications.FOOD, FLAVOR, FRAGRANCE• Measure Density, Specific Gravity• Checking of raw materials and product release• Check batch consistency and ensure proper blending ratios• May add refractive index, color and optical rotation to the density measurementPHARMACEUTICAL• Capable of 2,3,4 or more multiple measurements with standard deviation, mean, min and max reading for true cGLP/GMP compliance• Complete IQ/OQ/PQ documentation.• Checking of raw materials and product release• 21CFR11 Compliance; Electronic Signature and Secure Data Storage.• Compliant with USP <8417>, JP, BP and EPAlcohol Proof Testing • With 0.00001 g/cm3 accuracy the DDM 2911 PLUS is an excellent choice for the Alcohol Beverage industry to measure alcohol concentration to determine alcohol Proof• Easy to Use• Easy to Validate• Windows 7 Embedded OS integrates easily with you current systems• Precision built-in electronic Temperature Control• Easily combined with Rudolph’s R837 Automation System• 3 Year Warranty – 20 Year service GuaranteeThe capability you need to easily test your spirits production and comply with TTB Requirements:The DDM 2911 PLUS has built-in precision Electronic temperature control ensuring accurate and reproducible results. A Windows 7 embedded OS allows the operator to save calibration and measurement data right to ExcelTM.0.01% Alcohol Determination adding Precision to the Art of Craft DistillingRudolph Research Analytical 55 Newburgh Road, Hackettstown, NJ 07840 USA • Phone: 973-584-1558 • Fax: 973-584-5440 • E-mail: info@rudolphresearch.com • Internet: www.rudolphresearch.com12RRA935 1/15SpecificationsDDM 2910 DDM 2911 DDM 2911 PLUSAccuracy Density: 0.0001 g/cm3 Temperature: 0.05 °CDensity: 0.00005 g/cm3 Temperature: 0.03 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CRepeatability Density: 0.00005 g/cm3 Temperature: 0.02 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CDensity: 0.000005 g/cm3 Temperature Selectable: 0.001 °CResolution Density: 0.0001 g/cm3 Temperature: 0.01 °CDensity: 0.00001 g/cm3 Temperature: 0.01 °CDensity: 0.000001 g/cm3 Temperature Selectable to: 0.001°CDensity Ranges 0 to 3 g/cm3 Temperature Range 0 °C to 95°C (controlled via Peltier) Pressure 0 to 10 barsVideo Scanning & MagnificationThree magnified video assisted views of the entire cell are available, in 2x, 6x and a 10x magnifications with video scanning. Images maybe saved with results for subsequent review.Automatic Bubble DetectionAutomatically warns operator of bubblesMeasurement Modes Continuous, Single, MultipleMeasurement Technique Mechanical Oscillating U-Tube MethodMinimum Sample Volume Less than 1mLWetted Materials Borosilicate glass, Teflon PTFE ECTFEOperating Systems Windows 7® Embedded; write protected software safe from maleware and virusesMeasurement Time: 30 - 60 seconds after thermal equilibrationDisplay 10.4 inch diagonal TFT type LCD with wide viewing angle, anti-glare flat panel touch screen, 300 nits brightness, 800 x 600 pixels, chemical, scratch and spill resistant monitor, the industry’s largest and most flexible interfaceCommunication InterfaceTouch Screen User Interface, 5 – USB Ports, 2 – RS232 Ports, Ethernet Port for Network Connection, Keyboard Bar Code Scanner, Mouse, Network CapabilitiesRemote Support Touble shooting, Diagnostics, Software Updates available via the InternetInternal Memory 8 GB Non-removable Compact FlashOperating Dimensions 18.36” (L) x 11.80” (W) x 13.90” (H) 46.61 cm (L) x 29.97 cm (W) x 35.30 cm (H)Shipping Dimensions and Weight24.5” (L) x 17.5” (W) x 22” (H) 62cm (L) x 44cm (W) x 56cm (H)Shipping Weight 50 lbs. (23kg)Power Supply 85 to 260 VAC; 48 to 62 HzPower Consumption 140 Watts at peakOrigin of Manufacture and DesignUSA
Most popular related searches
