Anderson Instrument Co. LLC
- Home
- Companies & Suppliers
- Anderson Instrument Co. LLC
- Downloads
- Model ILM - Inductive Conductivity ...
Model ILM - Inductive Conductivity Meter - Brochure
F O O D1ANDERSON INSTRUMENT COMPANY INC.156 Auriesville RoadFultonville, NY 12072Phone 518-922-5315Fax 518-922-8997info@andinst.comInductive conductivity measurementApplication/Specifi ed usage · Inductive measurement of the specifi c conductivity of liquid media in the range of 0...999 mS/cm. · Designed for hygienic applications in food-, beverage- and pharmaceutical industries.Application examples · Controlling of CIP processes (e. g. phase separation detergents/water) · Concentration measurement (e.g. Alkali and acid concentration in remaking) · Monitoring of product quality, quality controlHygienic design/Process connection · Flow optimized, hygienic and easy sterilizable installation by sleeve EMZ-352 or the build-in system EHG-.../1". · CIP/SIP cleaning up to 140 °C (284 °F)/30 minutes maximum · Product contacting materials compliant to FDA · Sensor made of stainless steel, toroid housing made of PEEK · Conforming to 3-A Sanitary Standard 74-06 · Additional process connections:Tri-Clamp, Milchrohr (DIN 11851), Varivent, APV, DRD et alliFeatures/Advantages · Wearless inductive measurement principle. · Contrary to conductive measurement principle there are no problems caused by corrosion of the electrodes or polarization. · Up to 14 measurement ranges selectable, max. four external switchable (ILM-3). · Precise measurment by compensation of temperature infl uence. Each measurement range can be assigned a seperate temperature coeffi cient (ILM-3). · High reproducibility of = 1 % of measurement value. · Analog output for conductivity and temperature as standard. · Installation in pipes from DN 40 possible.Options/Accessories · Electrical connection via M12 plug-in connector · Version with longer bobbin case for pipes = DN 65 or for installation into T-fi ttingMeasuring principle of the inductive conductivity meterAn alternating current generates a magnetic fi eld in the primary coil (sender) which induces a current in the circumfl uent medium. The current fl ow in the medium gen-erates another magnetic fi eld in the secondary coil (receiver). The strength of the induced current in the secondary coil depends on the conductivity of the medium.The conductivity of the liquid medium is temperature dependent. To compensate the temperature error, an additional sensor (NTC) in the sensor tip is used for moni-toring the temperature of the medium. The temperature coeffi cient (TC-value) of the liquid can be set up in the electronics of the ILM which is used for automatic compen-sation of the temperature error.AuthorizationsProduct Information ILM-2 | ILM-3ILM-2-L20-M12ILM-2-L50-M12 with AMC-351-DN50Inductive Conductivity Meter ILM74-06Induced current fl ow I~Sender ReceiverMediumNTCF O O D 2SpecificationComparison ILM-2 / ILM-3 ILM-2 ILM-3Measurement ranges conductivity0...2 mS/cm up to 0...999 mS/cm 12 measurement ranges selectable 3 ranges extern switchable0...0.5 mS/cm up to 0...999 mS/cm 14 measurement ranges selectable 4 ranges extern switchableMeasurement ranges temperature 0...+150 °C 1 measurement range fix presetted-20...+150 °C 7 measurment ranges selectableTemperature coefficient (TC) 0...5 %/K, free adjustable 1 TC for all measurement ranges0...5 %/K, free adjustable 1 TC for each measurement rangeSpecificationProcess connections thread G1" torquesensor, combined with Negele-weld-in sleeves max. 20 NmMaterials connector head thread connection bobbin case window in lidstainless steel 1.4305 (303), Ø 89 mm stainless steel 1.4305 (303), SW 36 mm PEEK, FDA-number (21CFR177.2415) PMMATemperature ranges ambient process CIP/SIP cleaning-10...+60 °C (14...140 °F) 0...100 °C (32...212 °F) up to 140 °C (284 °F)/30 minutes max.Pressure 10 bar max. Protection class IP 69 K (with PG cable gland and suitable cable)Reproducibility of conductivity = 1 % of measurement valueResolution measurement range < 10 mS/cm 10...50 mS/cm 100...999 mS/cm 1 µS/cm 10 µS/cm 100 µS/cmAccuracy span offset±2 % of upper range value ±20 µS/cmLong term stability span offset±0.5 % of upper range value ±20 µS/cmAccuracy of the temperature output= 100 °C 100...150 °C0.5 °C max. 1.0 °C max. Electrical connection cable gland cable connection supply2 x M16 x 1.5 2 x M12 plug 1.4305 18...36 V DC max. 190 mAInputs range switching E1 and E2 (24 V DC) galvanically isolatedOutputs conductivity temperatureanalog 4...20 mA short-circuit-proof analog 4...20 mA short-circuit-proofLC-Display with backlight 2 x 8-digitsMeasurement principle wearless inductiveF O O D3 Mechanical Connection | InstallationDimensioned drawingThe sensors ILM-2 and ILM-3 conform to the 3-A sanitary standard 74-06 and are CIP/SIP cleanable when the following conditions are met: · Installed using CLEANadapt AMC-351, EMZ-351, or EMK-351 fittings. · Mounted such that the unit is self draining and the leak detection port on the fitting is located in accordance with the current 3-A standard. · When using the weld-in fitting EMZ or EMK, the weld must be done in accordance to 3-A accepted practices.Mechanical connection/Installation · The sensor has to be installed in a way that the toroid housing is entirely immersed in media and there are no bubbles present. Installation in a rising pipe is recommended. · The inscription “FLOW” on the bottom side of the sensor has to show in-flow direction of the medium. · Very heavy vibrations can cause measurement errors (e. g. installation very close to a pump). · Use Negele CLEANadapt system for safe operation of measuring point · Attention: The maximum tightening torque for mounting is 20 Nm · Use a welding mandril for correct installation of CLEAN-adapt weld-in fittings. Please pay attention to the weld-in and installation details in the CLEANadapt product information.20 / 5060 / 90F O O D 4InstallationElectrical connectionWith M12 plugHandling/OperationAdjustment of measuring range · Delivery status: measurement range 1: 0...20 mS/cm = 4...20 mA TC-value: 2 %/K · Via the external control voltage +24 V DC (18...36 V) range 2 (E1=24 V), range 3 (E2=24 V) or range 4 (E1=E2=24 V) can be selected (see “Electrical Connection”). · At ILM-3 each measurement range can be assigned a sepa-rate temperature coefficient (TC). At ILM-2 one and the same TC is effective for all measurement ranges. · At ILM-2 the temperature output is fix presetted to 0...150 °C. · At ILM-3 the measurement range of the temperature output can be selected from 7 preset ranges between -20...150 °CE1 E2 Meas. range0 0 11 0 20 1 31 1 4*Detecting the temperature coefficient of the mediumDelivery status: see Handling/Operation 1. Adjust “TC” to 0 %/K (see Adjustment).2. Dip sensor into medium with 25 °C (77 °F).3. Wait until the measurment value is stable.4. Record the conductivity value from the display.5. Warm up the medium to 60 °C (140 °F) minimum. There-by the conductivity value in the display is changing.6. Wait until the measurment value is stable.7. Select “TC” in the operation menu and adjust the tempe-rature coefficient until the measurement value is equal to the value noted at step 4.0 ? 0 V DC; 1 ? 24 V DC; Ground: clamp 9* only ILM-3Switching the measuring rangeThe digital control inputs E1 and E2 are galvanically isolated from supply voltage. AdviceOccuring several media with very different conductiv-ity in the application (e. g. CIP cleaning) switching to an adequate measuring range is neccessary for a precise measurementM12 plug left (4 pin) outputs 4...20 mA1: output conductivity +2: output temperature +3: output temperature -4: output conductivity -M12 plug right (5 pin) supply/control voltages1: supply +24 V DC2: digital input E23: 0 V (measurement range switching)4: supply5: digital input E1With S12 optionLeft (4 pin)1: conductivity -2: conductivity +3: supply +24 VDC4: supply -Right (5 pin)1: output temperature +2: digital input E23: 0 V (measurement range switching)4: output temperature -5: digital input E1F O O D5 OperationOperation menu ILM-2 Operation menu ILM-3Status messages LM-2 / ILM-3 ^-Symbol“Current output conductivity overload”,will be displayed if the measured value is higher than the selected measurment range.Iout: ca. 22 mA4 (upper line)currently editable range1 (lower line)currently activated measurement range^.^^^ -Symbolthe currently measured value is higher than the maximum measurement value (999 ms/cm)Iout: ca. 22 mA?-Symbolthe adjoining value is now editable via arrow buttonsvvv -Symbolinductor error/sensor breakIout: 2.4 mATemperaturecoefficientLevel TCMeasurement range 3(E2=24V)Measurement range 2(E1= 24V)Measurement range 1(E1, E2 0V) Displayconductivity and temperatureDisplay modeAfter 1 min. the device switches automatically back to the dis-play mode.StartTemperature outputTemperature coefficient 4Measurement range 4Temperature coefficient 3Measurement range 3Temperature coefficient 2Measurement range 2Temperature coefficient 1Measurement range 1 Displayconductivity and temperatureStartDisplay modeAfter 1 min. the device switches automatically back to the dis-play mode.F O O D 6Warnings | Application ExamplesCleaning/Maintenance · The ILM sensor is designed to be cleaned by CIP/SIP for a maximum temperature of 140 °C (284 °F) for 30 minutes. · In case of using pressure washers, don’t point nozzle directly to electrical connections.Disposal · This instrument is not subject to the WEEE directive 2002/96/EG and the respective national laws. · Pass the instrument directly to a specialised recycling company and do not use the municipal collecting points.Transport/Storage · Do not store outside · Store in an area that is dry and dust-free · Do not expose to corrosive media · Protect against solar radiation · Avoid mechanical shock and vibration · Storage temperature 0...40 °C (32...104 °F) · Relative humidity max. 80%Reshipment · Sensors and process connection must be clean and must not be contaminated with hazardous media and/or heat-conductive paste. Note the cleaning information. · Use suitable transport packaging only to avoid damage of the equipment.Phase separation in CIP-equipment with ILM-2 Phase separation in CIP-equipment with ILM-2Notice on conformityApplicable directives: · Electromagnetic Compatibility Equipment Directive 2004/108/EC · The CE label confirms compliance of this product with the applicable EC directives. · You have to guarantee the compliance of all guidelines applicable for the entire equipment.F O O D7 Process ConnectionsOverview of further possible process connections (adapter must be ordered separately)ILM-2ILM-3Process connectionDairy ? ange(DIN 11851) Varivent APV-InlineAdapterG1½" to G1" Dummy ? angeDN40 AMK-352/40 AMV-352 AMA-352AMG-352suitable for existing G1½" connectionBST-350to close existing measurement pointsDN50 AMK-352/50 AMV-352 AMA-352DN65 AMK-352/65 AMV-352 AMA-352DN80 AMK-352/80 AMV-352 AMA-352DN100 AMK-352/100 - AMA-352Overview of further possible process connections (adapter must be ordered separately)The complete overview of all available adapters you will fi nd at product information CLEANadapt.ILM-2ILM-3Use these fi ttings for applications requiring 3-A approvalProcess connectionTri-Clamp with Leak portWeld-in sleeve with Leak portCylindrical sleeve with weld-in ring and Leak portWeld-in sleeveBuild-in system EHG(DIN 11850 series 2)DN40 AMC-351/1"-1.5"EMZ-351suitable for pipes and vesselsEMS-351suitable for installation in pulled-out pipesEMZ-352suitable for installation in vesselsEHG-DIN2-40/1"DN50 AMC-351/2" EHG-DIN2-50/1"DN65 AMC-351/3" EHG-DIN2-65/1"DN80 AMC-351/80 EHG-DIN2-80/1"DN100 AMC-351/100 EHG-DIN2-100/1"F O O D 8ANDERSON INSTRUMENT COMPANY INC.156 Auriesville RoadFultonville, NY 12072Phone 518-922-5315Fax 518-922-8997info@andinst.com14.02.14 / 2.1 / TB / at-ac.deProduct Information ILM-2 | ILM-3AccessoriesCERT-2.2-ILM factory certificate 2.2 acc. to EN10204 (only product contacting surface)CAL - ILM factory calibration certificate for ILMOrder codeILM-2ILM-3(12 measurement ranges, 1 temperature coefficient, 3 measurement ranges external switchable)(14 measurement ranges, 4 temperature coefficients, 4 measurement ranges external switchable)Insertion lengthL20 L50(20 mm) (50 mm)Electrical connection (configuration see page 4)PG M12 S12(cable gland M16x1.5) (M12 plug-in 1.4305 (303)) (M12 plug-in 1.4305 (303))ILM-2 - L20 - S12Notes
Most popular related searches
