Anderson Instrument Co. LLC
- Home
- Companies & Suppliers
- Anderson Instrument Co. LLC
- Downloads
- Model SL - Inventory Grade Hydrostatic ...
Model SL - Inventory Grade Hydrostatic Level Transmitter - Brochure
"SL" Level TransmitterA n d e r s o n I n s t r u m e n t Company ’s "SL" Leve l Transmitter is the latest innovation for measuring l iquid level in sani tary appl icat ions. The "SL" Transmitter incorporates state of the art design to provide superior accuracy and long term signal stability. The field tested performance of the "SL" transmitter means the elimination of expensive, repetitive re-calibrations along with protection against costly overflow/run-dry situations that can occur with less stable level transmitters. The 0.2%accuracy experienced at installation can now be expected a year later We’ve also incorporated a field calibration feature that provides “one-touch” sensor zeroing as well as simple range calibration, without the need for special tools and fixtures, pressure sources, or removal of the transmitter from the tank. This translates to real cost savings during installation or when adjusting for new application requirements. With the addition of our standard quick disconnect receptacles; we have even extended our two-year warranty to cover water ingression. Of course the "SL" Transmitter is available in all standard fitting and range combinations you’ll need to fit any sanitary tank application. All variations are CE compliant, meet appl icable 3-A Sanitary Standards, and are backed by a 2-year warranty.New technology proven to eliminate long-term signal drift — provides substantial savings in all inventory applications• Fewer tune-ups• No more overflows• More reliable inventories• 3-A compliant; Third party verified Special Features Include:• Quick Disconnect Receptacles with optional Field Wiring Connectors• One-Touch Field Calibration• Available with Hart CommunicationF L O W L E V E LP R E S S U R EA N A L Y T I C A L T E M P E R A T U R EI N S T R U M E N T A T I O NP A S T E U R I Z A T I O N C O N T R O L SAPPLICATIONS• Inventory Control• Batching/Mixing Control• Both Conductive and Non Conductive FluidsANDERSON INSTRUMENT CO., INC • 156 AURIESVILLE RD. • FULTONVILLE, NY 12072 • USA • 800-833-0081 • FAX 518-922-8997ANDERSON INSTRUMENT CO. LP • 400 BRITANNIA RD. EAST, UNIT 1 • MISSISSAUGA, ONTARIO L4Z 1X9 • CANADA • 905-603-4358 • FAX 905-568-1652NEGELE MESSTECHNIK GmbH • RAIFFEISENWEG 7 • D-87743 EGG A. D. GüNZ • GERMANY • +49 (0) 8333/9204-0 • FAX +49 (0) 8333/9204-49www.andinst.comSL SpecificationsPerformanceLevel Measurement Ranges: (Factory calibrated at no charge and easily field calibrated within the parameters listed below) Minimum Maximum (URL*) Proof PressureSL1 & SL5 Series 0-30 " w.c.** 0-140 " w.c. 10 psigSL2 & SL6 Series 0-140.1 " w.c. 0-415 " w.c. 30 psigSL3 & SL7 Series 0-415.1 " w.c. 0-830 " w.c. 60 psigSL4 & SL8 Series 0-830.1 " w.c. 0-1385 " w.c. 100 psigRanges to accomodate vacuum available on requestCalibrated Accuracy: (includes repeatability, hysteresis, and linearity) ± 0.20% of URL at stable calibration temperature Calibration Stability: Within ±0.2% of URL for one (1) year minimumResolution: InfiniteProcess Temperature Limits: 0°F to 265°F (-18°C to 130°C)Ambient Temperature Limits: 15°F to 120°F (-9°C to 49°C)Compensated Temp. Range: 0°F to 250°F (-18°C to 121°C) (process) Temperature Stability: ±0.2% of Upper Range Limit (URL) per 10°F (5.5°C)Over-Range Capacity: 2 times the URL (see table above)Response Time: 526 mSecCommunication Standard: Analog, 4-20mA outputOptional: Analog + Hart digital protocol. Does not support Multidrop modePower SignalLoop Power (excitation): 12-40 vdcOutput: 4-20mA dc, 2-wire. Internal test points suppliedLoop Resistance: 1550 ohms (max.) at 40 vdc, 750 ohms (max) at 24 vdcCable Recommended: 2 conductor, stranded, 18-24 AWG, shielded with ground. 0.17 - 0.26” Cable Sheath OD for use with field wiring connector. Anderson molded cord set recommended for best EMI and water protection.Receptacle: 5-pin M12 Quick Disconnect ReceptacleMaterials/ConstructionHousing Material: 304 and 316 stainless steel finished to 32Ra maxWetted Parts: 316L stainless steel electropolished to 15Ra maxRatings: NEMA 4X, IP-66, IP-67Agency ApprovalsElectromagnetic Compatibility(EMC): Fully CE Compliant when equipped with shielded molded cord setStandards: 3-A compliant; Third Party Verified Designed and manufactured to sound engineering practices in accordance with Article 3.3 of the PED 97/23/ECWarranty: All units are covered by a two (2) year warranty against defects in material and workmanship when installed and maintained according to the instruction manual provided* URL = Upper Range Limit ** w.c. = water columnKit - Field Wireable Connector and Receptaclewith Dielectric Grease P/N: 56642A0001Loop- (black) wireShield (clear or bare) wire90° Field Wireable ConnectorP/N: 42119A0000 (without cable)ReceptacleP/N: 56623A0002Electrical Connections and Wiring Options*Dielectric GreaseP/N: 5662400000Field Wireable ConnectorP/N: 42119B0000 (without cable)Molded CordsetShield CordsetLoop+(red) wire Pin 1Loop+(red) wire Pin 1Loop-(black) wire Pin 2Loop-(black) wire Pin 2Shield (clear or bare) wire - not connected to nutShield (bare) wire - connected to nut0.17-0.26" Cable Sheath DiameterSPAN RANGE 1 0-30” min to 0-140” max with Hart 2 0-140.1” to 0-415” max with Hart 3 0-415.1” to 0-830” max with Hart 4 0-830.1” to 0-1385” max with Hart 5 0-30” min to 0-140” max 6 0-140.1” to 0-415” max 7 0-415.1” to 0-830” max 8 0-830.1” to 0-1385” max FITTING 089 Anderson Flush Mount Long (71060-A3, A5, A7, A9) 088 Anderson Flush Mount Short (71060-A4, A6, A8) 091 Cherry Burrell Flush Mount Long (insulated tank) 090 Cherry Burrell Flush Mount Short (uninsulated tank) 092 King Gage Flush Mount Long 3 (1777-3) 093 King Gage Flush Mount Medium (1777-1, -6 Standard) 094 King Gage Flush Mount Short (1777-2 non-insulated) 097 Tank Mate Flush Mount Long 1,3 (208WVE) 096 Tank Mate Flush Mount Medium 1 (205WVE) 095 Tank Mate Flush Mount Short 1 (200WVE) 004 1-1/2” Tri-Clamp 005 2” Tri-Clamp 007 3” Tri-Clamp 059 1-1/2” NPT 3, 4 147 Continental (long) 146 Continental (short) 3 141 Rosemount / Foxboro Sanitary Spud - Short 3 142 Rosemount / Foxboro Sanitary Spud - Long 3 154 Endress & Hauser Universal Adaptor - Short 155 Endress & Hauser Universal Adaptor - Long 169 Liquid Scale Flush Mount Medium 2,3DIAPHRAGM 1 SS-316L Electropolished 2 Hastelloy “C” (N/A with King-Gage, Tank Mate, or Endress & Hauser Fittings)How to Order*Note: Calibration of span is in units “inches water column”. Consult factory for assistance.Gaskets for Flush Mount Level TransmittersAnderson 44348A0001 Cherry Burrell 44292A0001 King Gage 36240S0212 Tank Mate 36240S0123 Continental 5658900000 Sensor Calibration AdaptorsAnderson fitting 73198A0001 Cherry Burrell fitting 73198A0002 King Gage Fitting 73198A0003 Tankmate 73198A0004Cord SetsMolded w/25’ cable 42117K0025Molded w/50’ cable 42117K0050Molded w/100’ cable 42117K01005-Conductor w/25’ cable 42117H00255-Conductor w/50’ cable 42117H00505-Conductor w/100’ cable 42117H0100ACCESSORIESAnderson Weld-In Shells for Flush Mount Level Transmitters71060A0003 Insulated Vessel - Standard Flange - 316L 71060A0004 Uninsulated Vessel - Standard Flange - 316L 71060A0005 Insulated Vessel - Pressure Vessel Flange - 316L 71060A0006 Uninsulated Vessel - Pressure Vessel Flange - 316L 71060A0009 Insulated Vessel - H/D Press. Vessel Flange - 316L Shell AdaptorTank Mate, uninsulated 57200A0002 Tank Mate, insulated 57200A0001 S LMOUNTING 0 Horizontal 1 Vertical 2 Other (specify angle from vertical or from horizontal)CALIBRATION ** ##### Height in inches w.c.* (to nearest tenth)00000 Field CalibratedExamples: 10850 1,085.0 inches 00305 30.5 inchesSENSOR WIRING 01 Quick Disconnect Receptacle (QDR) & Field Wireable Connector (FWC) w/No Cable (std.) R0 QDR & 90° FWC w/No Cable 00 QDR w/No Cable, no FWC 05 QDR w/25 ft Standard Molded Cordset 10 QDR w/50 ft Standard Molded Cordset 20 QDR w/100 ft Standard Molded Cordset 99 1/2" NPT No QDR, no FWC and no Cable (No sensor warranty for water damage)**Note: Orders not accepted without calibration data or completed worksheet.1 Requires Tank Mate Shell Adapter: 57200A0001 (insulated) 57200A0002 (uninsulated) 2 Requires Liquid Scale Shell Adaptor: 4593600000 3 Sensors with these fittings are non-cancellable/non-returnable for credit4 Not 3-A compliant Sensor Fittings and DimensionsFORM AIC5006© April 1999Revised: March 2013Supersedes: November 2012ANDERSON SHELL TYPE "A"NON INSULATED 2-3/16INSULATED 6-1/2KING SHELL TYPE "A"NON INSULATED 2-3/16STANDARD 6-9/16LONG 8-13/16TANK MATE SHELL TYPE "A"SHORT 5-7/32MEDIUM 7-19/64LONG 10-3/16CHERRY BURRELL SHELL TYPE "A"NON INSULATED 2-3/16INSULATED 6-1/2FITTING "A" DIM. "B" DIM.ROSEMOUNT SHORT 2.11" 5-1/2"ROSEMOUNT LONG 6.11" 9-1/2"DESCRIPTION - USE "A" DIM.E+H LONG (6" SHELL) 6.60E+H SHORT (1-9/16" SHELL) 2.16CONTINENTAL SHELL TYPE "A"NON INSULATED 2-5/32INSULATED 6-3/161-1/2" OR 2" TRI-CLAMP3-19/64"5-1/4"2" DIA."A""A"NON INSULATEDINSULATEDANDERSON SHELL TYPE6-1/22-3/163"3-7/64"3-19/64"1-7/16" DIA."A"2-3/4"2-3/166-1/2CHERRY BURRELL SHELL TYPEINSULATEDNON INSULATED"A"3-19/64"3-7/64"2-3/166-9/168-13/16KING SHELL TYPELONGSTANDARDNON INSULATED1-1/4" DIA."A"2-1/4""A"3-7/64"3-19/64"TANK MATE SHELL TYPESHORTLONGMEDIUM10-3/167-19/645-7/32"A""A"1-9/16" DIA.3"3-7/64"3-19/64"1-1/2" N.P.T3-19/64"6-39/64”1-1/2" OR 2" TRI-CLAMP3-19/64"5-1/4"2" DIA."A""A"NON INSULATEDINSULATEDANDERSON SHELL TYPE6-1/22-3/163"3-7/64"3-19/64"1-7/16" DIA."A"2-3/4"2-3/166-1/2CHERRY BURRELL SHELL TYPEINSULATEDNON INSULATED"A"3-19/64"3-7/64"2-3/166-9/168-13/16KING SHELL TYPELONGSTANDARDNON INSULATED1-1/4" DIA."A"2-1/4""A"3-7/64"3-19/64"TANK MATE SHELL TYPESHORTLONGMEDIUM10-3/167-19/645-7/32"A""A"1-9/16" DIA.3"3-7/64"3-19/64"1-1/2" N.P.T3-19/64"6-39/64”1-1/2" OR 2" TRI-CLAMP3-19/64"5-1/4"2" DIA."A""A"NON INSULATEDINSULATEDANDERSON SHELL TYPE6-1/22-3/163"3-7/64"3-19/64"1-7/16" DIA."A"2-3/4"2-3/166-1/2CHERRY BURRELL SHELL TYPEINSULATEDNON INSULATED"A"3-19/64"3-7/64"2-3/166-9/168-13/16KING SHELL TYPELONGSTANDARDNON INSULATED1-1/4" DIA."A"2-1/4""A"3-7/64"3-19/64"TANK MATE SHELL TYPESHORTLONGMEDIUM10-3/167-19/645-7/32"A""A"1-9/16" DIA.3"3-7/64"3-19/64"1-1/2" N.P.T3-19/64"6-39/64”1-1/2" OR 2" TRI-CLAMP3-19/64"5-1/4"2" DIA."A""A"NON INSULATEDINSULATEDANDERSON SHELL TYPE6-1/22-3/163"3-7/64"3-19/64"1-7/16" DIA."A"2-3/4"2-3/166-1/2CHERRY BURRELL SHELL TYPEINSULATEDNON INSULATED"A"3-19/64"3-7/64"2-3/166-9/168-13/16KING SHELL TYPELONGSTANDARDNON INSULATED1-1/4" DIA."A"2-1/4""A"3-7/64"3-19/64"TANK MATE SHELL TYPESHORTLONGMEDIUM10-3/167-19/645-7/32"A""A"1-9/16" DIA.3"3-7/64"3-19/64"1-1/2" N.P.T3-19/64"6-39/64”1-1/2" N.P.T.6-39/64"3-19/64"5-1/4”3-19/64”1-1/2”,2” OR3” TRICLAMP
Most popular related searches
