Advantic Sistemas y Servicios S.L

MPC-333 - Datalogger Controller - Data Sheet

MPC-333 Datalogger GPRS/GSM LAN MPC333-DS001 Oct 2012 Pag. 1/3 Overview ? Datalogger with timestamp of records (RTC, Real Time Clock). ? Ethernet, USB, RS232, RS485, GSM/GPRS, M-Bus communication. ? Galvanic isolation between power suply and interfaces. ? Remote configuration and updates through GSM/GPRS or Ethernet port. ? Protocols Modbus RTU, Modbus TCP/IP, M-Bus, Data/Req, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, IEC60870-5-104:2000. ? External devices power suply (up to 10Vcc / 20mA) ? Up to 8 digital inputs (contact / impulse / alarm). General description MPC-333 Controller was designed to measure, record and analyze real time signals. Stored data can be sent to remote users through GSM/GPRS modem or Ethernet port. In the event of loss of communication, the data is safely stored in the internal memory until communication is restored, providing safety and reliability to processes and control systems. Supports the most common protocols over serial or remote port (such as M-Bus, Modbus TCP/IP, Modbus RTU, IEC60870-5-104: 2000 ...), and a special transmission mode; “transparent mode” for special manufacturer protocol, so almost any device can be connected. Some potential applications of the MPC-333 are; environment sensors and events logging in control systems, remote electricity consumption monitoring, remote management for isolated installations, energy efficiency systems... all through a single device with open & standard communication (Modbus), greatly simplifying its implementation within the SCADA / user software. The communication ports are selectable, allowing you to choose exactly the necessary equipment for each installation. Ordering code Model Interface Interface Interface Interface Interface Ext. suply Digital inputs RTC Suply 702 . 031 . A B C D . E . F . G . H . I 0 – None 1 – GPRS 2 – RS232 0 – None 1 – RS485 2 – RS232 3 – Data/Req 4 – M-Bus 5 – Current loop 0 – None 1 – RS485 2 – RS232 3 – Data/Req 5 – Current loop 0 – None 1 – RS485 2 – RS232 0 – None 1 – Ethernet 0 – None 1 – External power suply 0 – None 4 – 4 digital inputs 8 – 8 digital inputs 0 – None 1 – Real Time Clock (RTC) 1 – Power suply 9-36 Vdc 2 – Power suply 12-50 Vdc Example: 702.031.1412.1.0.8.1.2 GSM/GPRS modem, M-Bus port, RS485 port, RS232 port, Ethernet, w/o power suply for external devices, 8 digital inputs, RTC and power suply. MPC-333 Datalogger GPRS/GSM LAN MPC333-DS001 Oct 2012 Pag. 2/3 Characteristics General Power suply: 9 – 36 Vcc / 12 – 50Vcc Overvoltage protection: >1000V (max. 5 sec) Consumption: <10 VA Power consumption: Specifications CPU: ARM7 (55MHz) GSM/GPRS: 3 bands 900/1800/1900 MHz Flash: 2 MB (Up to 8 MB,under request*) Up to 5 years storage. Interfaces RS232: Up to 15m distance, speed up to 19,2 Kbits/s RS485: Up to 1.2 km de distancia, speed up to 19.2 Kbits/s USB: (configuration) Tipo B, ver. 2.0 Ethernet: RJ45 Twisted pair Ethernet 10/100 Mb, up to 100m. Current loop: <30V, 14-20mA, up to 6 km, speed up to 19,2 Kbit/s M-Bus: Up to 8 devices. Self configurable Data/Req: KAMSTRUP Up to 8 devices. Digital inputs. 4/8 contact/impulse inputs External devices power suply 3,7/5/6/8/10 Vcc max. 20mA Protocols Modbus RTU, Modbus TCP/IP, IP, ICMP, UDP, TCP, DHCP, PPP, ARP, IEC60870-5-104:2000 LED Indication Power suply Read/write of each port GSM/GPRS connection status Ethernet connection status On/Off indication of each digital inputs Climate conditions Working temperature: -25 .. +60oC Storage temperature: -40 .. +60oC Humidity range: 5 – 95%, w/o condensation Regulatory approvals EN 55022:2010 EN 55024:2010 EN 61000-4-2:2009 EN 61000-4-3:2006 EN 61000-4-3:2006/A1:2008 EN 61000-4-3:2006/A2:2010 EN 61000-4-4:2004 EN 61000-4-4:2004/A1:2010 EN 61000-4-6:2009 EN 60950-1:2006 EN 60950-1:2006/A11:2009 Physical characteristics Dimensions: 197x128x50 mm Weight: 400 g Material: PC/ABS Protection type: IP20 Mounting DIN rail Other features Made in EU * Consultar disponibilidad Dimensions (mm) 50 197 128 MPC-333 Datalogger GPRS/GSM LAN MPC333-DS001 Oct 2012 Pag. 3/3 Connection All the connection terminal blocks are removable, which facilitate the wiring process. Power suply (w/o polarity) Digital inputs (4 / 8) M-Bus RS232 port RS485 port Data/Req Operation Configurations and updates are made using the software MPC-Config Tool, through local ports (USB, RS232, RS485) or remote connection through GSM/GPRS modem or Ethernet port (default socket port: 502) To access advanced features, please contact with Advanticsys technical support. Cautions ? Installation and wiring must be made only by qualified personal. ? Remove power suply before connect or disconnect the input/output terminal blocks. ? Double-check connections and polarities before switch on the power suply to avoid permanent damages. The information contained in this datasheet is subject to change without notice. Make sure you’re using the latest version. Advantic Sistemas y Servicios S.L www.advanticsys.com Avda. Europa 14 info@advanticsys.com 28108 Alcobendas (Madrid) - SPAIN +34 91 189 05 21
Most popular related searches