Fuel Cells Etc
Nafion 211 and 212 Property Sheet - FuelCellsEtc
DuPont Fuel Cells DuPont™ Nafion® PFSA Membranes NR-211 and NR-212 Description Description DuPont™ Nafion® PFSA NR-211 and NR-212 membranes are based on chemically stabilized perfluorosulfonic acid/PTFE copolymer in the acid (H+) form, and exhibit substantially lower fluoride ion release compared to the non-stabilized polymer – a sign of improved chemical durability. Nafion® PFSA membranes are widely used for Proton Exchange Membrane (PEM) fuel cells and water electrolyzers. The membrane performs as a separator and solid electrolyte in a variety of electrochemical cells that require the membrane to selectively transport cations across the cell junction. The polymer is chemically resistant and durable. DuPont™ Nafion® PFSA NR-211 and NR-212 membranes are based on chemically stabilized perfluorosulfonic acid/PTFE copolymer in the acid (H+) form, and exhibit substantially lower fluoride ion release compared to the non-stabilized polymer – a sign of improved chemical durability. Nafion® PFSA membranes are widely used for Proton Exchange Membrane (PEM) fuel cells and water electrolyzers. The membrane performs as a separator and solid electrolyte in a variety of electrochemical cells that require the membrane to selectively transport cations across the cell junction. The polymer is chemically resistant and durable. The membrane is positioned between a backing film and a coversheet. This composite is wound on a 6 inch ID plastic core, with the backing film facing out, as shown in Figure 1. A 6 inch ID plastic roll core is the standard. However, a 3 inch ID plastic roll core is used for roll lengths that are less than 25 meters long. The membrane is positioned between a backing film and a coversheet. This composite is wound on a 6 inch ID plastic core, with the backing film facing out, as shown in Figure 1. A 6 inch ID plastic roll core is the standard. However, a 3 inch ID plastic roll core is used for roll lengths that are less than 25 meters long. Figure 1: Roll Unwind Orientation (Backing Film Facing Out) Figure 1: Roll Unwind Orientation (Backing Film Facing Out) Backing FilmBacking FilmMembraneCoversheetMembrane The backing film facilitates transporting the membrane into automated MEA fabrication processes, while the coversheet protects the membrane from exposure to the environment during intermediate handling and processing. In addition, the coversheet (in combination with the backing film) eliminates rapid changes in the membrane's moisture content, and stabilizes the dimensions of the membrane as it is removed from the roll. Order and Packaging Information Nafion® PFSA membranes are available in two thickness values: NR-211 (1-mil) and NR-212 (2-mil). Standard product dimensions for membrane rolls include: Width: 305-mm and 610-mm standard roll widths, and intermediate widths from 200-mm (min.) up to 610-mm (max.) on special order. Intermediate widths available in increments of 3.175-mm. Length: 100-meter standard roll length, and intermediate lengths of 10-meter and 50-meter on special order. There is a 100-m2 minimum order requirement for non-standard roll widths; and a per roll packaging surcharge for standard widths in non-standard lengths less than 100-meters. A roll core leader is available at a nominal charge per roll. Please contact Nafion® customer service for details and availability. Rolls are splice-free when ordered in standard 100-meter lengths. Non-standard roll lengths may contain splices under the following conditions: a 5-meter minimum distance between splices and a maximum of 3 splices per roll that is less than 100-meters in length. The water content and conditioning of the membrane will affect its dimensions, and the change may not be symmetrical in the length, width, and thickness directions. Once the cover sheet is removed, the membrane will respond to the environmental conditions of the workplace. If the membrane remains on the backing film, the membrane's response to relative humidity conditions, for example, may cause the combination of membrane/backing film to curl. In addition, certain manufacturing steps performed by the customer also may affect the membrane's dimensions and flatness. If specified in the purchase order, a roll core leader is attached to the membrane as shown in Figure 2. The roll core leader material is the same as the backing film, and the length specified in the purchase order. Figure 2: Splice Design Roll Core LeaderDouble-Stick TapeBacking FilmMembrane Cover Sheet Overlap Splice BetweenMembrane and Roll Core Leader Peel-Back and Remove Cover Sheet in the Splice Area Splice Design for AttachingRoll Core Leader to MembraneStart of Membrane on Roll Properties of Nafion® PFSA Membrane A. Thickness and Basis Weight Properties1 Membrane Type Typical Thickness (micrometer) Basis Weight (g/m2) NR-211 25.4 50 NR-212 50.8 100 B. Physical Properties Typical Values NR-211 NR-212 Property2 MD TD MD TD Test Method Physical Properties - measured at 50% RH, 23 °C Tensile Strength, max., MPa 23 28 32 32 ASTM D 882 Non-Std Modulus, MPa 288 281 266 251 ASTM D 882 Elongation to Break, % 252 311 343 352 ASTM D 882 C. Other Properties Property NR-211 NR-212 Test Method Specific Gravity1 1.97 1.97 DuPont Available Acid Capacity3 meq/g 0.92 min. 0.92 min. DuPont NAE305 Total Acid Capacity4 meq/g 0.95 to 1.01 0.95 to 1.01 DuPont NAE305 Hydrogen Crossover5, (ml/min·cm2) < 0.020 < 0.010 DuPont D. Hydrolytic Properties Property Typical Value Test Method Hydrolytic Properties Water content, % water6 5.0 ± 3.0% ASTM D 570 Water uptake, % water7 50.0 ± 5.0% ASTM D 570 Linear expansion, % increase8 from 50% RH, 23 °C to water soaked, 23 °C 10 ASTM D 756 from 50% RH, 23 °C to water soaked, 100 °C 15 ASTM D 756 1 Measurements taken with membrane conditioned to 23 °C, 50% RH. 2 Where specified, MD - machine direction, TD - transverse direction. Condition state of membrane given. 3 A base titration procedure measures the equivalents of sulfonic acid in the polymer, and used the measurements to calculate the available acid capacity of the membrane (acid form). 4 A base titration procedure measures the equivalents of sulfonic acid in the polymer, and used the measurements to calculate the total acid capacity or equivalent weight of the membrane (acid form). 5 Hydrogen crossover measured at 22 °C, 100% RH and 50-psi delta pressure. This is not a routine test. 6 Water content of membrane conditioned to 23 °C and 50% RH (dry weight basis). 7 Water uptake from dry membrane to conditioned in water at 100 °C for 1 hour (dry weight basis). 8 Average of MD and TD. MD expansion is similar to TD expansion for NR membranes. Product Labeling A self-adhesive product label, with information content similar to Figure 3, is located on the inside of the roll core and on the outside over-wrap of each roll. The label indicates the product roll's width and length in both metric and English units. Figure 3: Finished Product Roll Label Information Product: NR-212 SN: D12345678 Width: 30.50 cm Length: 100 m Width: 12 in Length: 328 ft BN: X0103-1003 SEQ: 1 • SN is a product setup code specific to the thickness, roll width and length, and other packaging features (e.g., core leader, etc.). • BN is a 2-part code, with the first part identifying the dispersion batch number, and the second part indicating the master roll number (wide-stock roll before slitting). • SEQ is a sequential roll number (starting at 1, 2, 3, etc.) indicating the total number of finished rolls slit from the wide-stock master roll. The SEQ roll number is indicated only on the labels attached to the membrane and the roll core's ID. The manufactured date is the wide-stock roll's slit date (mm/yyyy), and is printed on the label attached to the outside of the roll's shipping box. Recommended Roll Storage Conditions Unopened roll packages of Nafion® PFSA membrane should be stored in the original shipping box, out of direct sunlight, and in a climate-controlled environment, maintained at 10 to 30°C, and 30 to 70% relative humidity. Before opening the package, pre-condition the membrane roll to the processing area temperature for 24 hours. Once opened and exposed to the environment, the membrane will equilibrate to the ambient relative humidity, and change in dimensions accordingly. Membrane order dimensions are specified and measured at 23°C and 50% relative humidity. Handling Practices Ventilation should be provided for safe handling and processing of Nafion® PFSA membrane. The amount of local exhaust necessary for processing Nafion® PFSA membrane at elevated temperatures will depend on the combined factors of membrane quantity, temperature, and exposure time. Scrap Disposal Preferred disposal options are (1) recycling and (2) landfill. Incinerate only if incinerator is capable of scrubbing out hydrogen fluoride and other acidic combustion products. Treatment, storage, transportation, and disposal must be in accordance with applicable federal, state/provincial and local regulations. Static Discharges The composite structure and individual layers can pick up a strong charge of static electricity because of the good dielectric properties of the membrane, backing film, and coversheet. Unless this charge is dissipated as it forms, by using ionizing radiation devices or special conducting metal tinsel, it can build to thousands of volts and discharge to people or metal equipment. In dust- or solvent-laden air, a flash fire or an explosion could follow. Extreme caution is needed to prevent static accumulation when using flammable solvents while coating membrane surfaces. Solvent-coating equipment should incorporate the means for detecting and extinguishing fire. Safe Handling and Use of Nafion® PFSA Membranes The following information should be reviewed before handling and processing Nafion® PFSA Membranes: • DuPont Material Safety Data Sheet for Nafion® PFSA Membranes NR-211 and NR-212 • Nafion® Technical Information "Safe Handling and Use" • "Guide to Safe Handling of Fluoropolymer Resins", Fourth Edition, November 2005, Published by the Fluoropolymers Division of the Society of the Plastics Industry, Inc. Separating NRE Membrane from the Coversheet and Backing Film: Adhesive Tape applied to front-side Adhesive Tape applied to back-sideDo not "overlap" thetapes at the extremeedge Backing Film Coversheet NR Membrane NR Membrane "Package" Membane between Top Coversheet and Backing Film • Attach tapes to front and back sides of the NR membrane "package" at one corner, as shown in the diagram. To prevent the tapes from sticking to each other, do not "overlap" the adhesive surfaces at the extreme edges. • Pull the tapes apart to separate the coversheet from the membrane/backing film. The membrane typically adheres to the backing film during this step. The coversheet is 0.7-mil polypropylene film. • Attach tapes to the membrane side and the backing film side at one corner, as shown in the diagram. To prevent the tapes from sticking to each other, do not "overlap" the adhesive surfaces at the extreme edges. • Pull the tapes apart to separate the membrane from the backing film. The backing film is 2-mil polyester film. Copyright © 2008 DuPont or its affiliates. The DuPont Oval Logo, DuPontTM, The miracles of scienceTM, and Nafion® are trademarks or registered trademarks of E. I. du Pont de Nemours and Company or its affiliates. DFC201.0708 The data listed here fall within the normal range of product properties, but they should not be used to establish specification limits nor used alone as the basis of design. This information is based on technical data that DuPont believes to be reliable. It is intended for use by persons having technical skill and at their own discretion and risk. This information is given with the understanding that those using it will satisfy themselves that their particular conditions of use present no health or safety hazards. Because conditions of product use are outside our control, DuPont makes no warranties, express or implied, and assumes no obligation or liability in connection with any use of this information or for results obtained in reliance thereon. The disclosure of the information is not a license to operate under or a recommendation to infringe any patent of DuPont or others. Caution: Do not use in medical applications involving permanent implantation in the human body. For other medical applications, see “DuPont Medical Caution Statement”, H-50102. For information about product offerings from DuPont Fuel Cells, contact: UNITED STATES, CANADA, MEXICO and CENTRAL AMERICA Nafion® Membranes and Dispersions MEA Components DuPont Fuel Cells P.O. Box 80701 Wilmington, DE 19880-0701 Fax: (302) 355-0828 EUROPE, MIDDLE EAST and AFRICA Nafion® Membranes and Dispersions DuPont Via A. Volta 16 20093 Cologno Monzese Milano, Italy Fax: +39.02.27300969 MEA Components DuPont 2 Chemin du Pavillion CH-1228 Le Grand-Saconnex Geneva, Switzerland Fax: +41.22.717.5411 JAPAN SOUTH AMERICA DuPont Kabushiki Kaisha 4th Floor Chiyoda Honsha Bldg. 5-18, Sarugaku-cho 1-chrome Chiyoda-Ku, Tokyo 101-0064 Fax: (03) 5281-5899 DuPont do Brasil SA Alameda Itapecuru, 506 – Alphaville Barueri - S.P. Brazil CEP 06454-080 CHINA KOREA DuPont China Holding Co., Ltd. 15th Floor, Shui On Plaza 333 Huai Hai Road (Central) Shanghai 200021, China DuPont Korea, Inc. 3-5th Floors, Asia Tower #726 Yeoksam-dong, Kangnam-Ku Seoul 135-719 Korea TAIWAN INDIA DuPont Taiwan Limited Hung Kuo Bldg. 13th Floor, 167 Tun Hwa North Road Taipei, Taiwan 105 E.I. DuPont India Pvt. Ltd. DLF Plaza Tower DLF Qutab Enclave, Phase 1 Gurgaon 122 002 Haryana, India fuelcells.dupont.com Description Order and Packaging Information Properties of Nafion® PFSA Membrane Product Labeling Recommended Roll Storage Conditions Handling Practices Scrap Disposal Static Discharges Safe Handling and Use of Nafion® PFSA Membranes Separating NRE Membrane from the Coversheet and Backing Film: For information about product offerings from DuPont Fuel Cells, contact: UNITED STATES, CANADA, MEXICO and CENTRAL AMERICA EUROPE, MIDDLE EAST and AFRICA JAPAN SOUTH AMERICA CHINA KOREA TAIWAN INDIA
Most popular related searches
