Argonide Corporation

NanoCeram - Model LR Series - Lenticular Replacement Pleated Filter Cartridges Brochure

Argonide’s NanoCeram-LRTM Series Pleated Filter Cartridges (LR-19) have been designed to replace standard lenticular filters with advantages of improved efficiency and increased capacity and to fit into existing lenticular filter housings. The NanoCeram-LR has a single pore size (2 µm) for all applications and effectively removes particulates down to 5 nm (0.005 µm). The unique construction of the NanoCeram-LR directs water flow through the two pleated layers of Argonide’s patented media and combines high efficiency and high dirt holding capacity while providing superior flow rates at low differential pressures. The NanoCeram-LR exhibits high removal efficiency of submicron particles including virus, bacteria, metals, metal oxides and other colloidal materials. Each LR-19 contains over 19 square feet of NanoCeram electropositive filter media and is individually packaged. NanoCeram-LRTM Series Lenticular Replacement Pleated Filter Cartridges Markets  Food, Beverage & Bottled Water  Pharmaceutical  Cosmetics & Personal Care  MicroElectronics  Power Generation  Inks, Paints & Coatings Features  Effective at high pH and in the presence of salt  Pleated Construction yields high flow rates compared to traditional lenticular filters  Available in all standard end configurations for lenticular filters  Provides optical clarification to fluids  Manufactured with strict quality control  All LR-19 Components are manufactured with materials that meet FDA requirements 21CFR177.1520 for direct food contact applications. Applications  Make Up Water (Particulate, Microbial Control)  Polishing Filters (Carbon Fines Removal)  RO Prefiltration (SDI reduction)  Process Water (Turbidity, Particulate, Colloidal Suspensions)  Waste Water (Biologicals, Proteins, Dyes)  Cooling Towers (Iron Removal)  Clarifying Filtration of Cell Cultures  Protection for Chromatography Columns and Membranes Retention Characteristics  >99.99% Efficiency at 0.2 microns  >4 LRV Cyst Retention  >6 LRV Virus Retention  >7.5 LRV E. coli Retention  >99.95% Endotoxin Removal (235 to <0.12 EU//ml @ 10 mL//cm2//min)  <0.01 NTU until Terminal ∆P (35 psid) using A2 Fine Test Dust Argonide Corp., 291 Power CT, Sanford, FL 32771 Tel: 407-322-2500 Fax: 407-322-1144 www.argonide.com NanoCeram is a Registered Trademark of Argonide Corporation. NanoCeram-LR is a Trademark of Argonide Corporation. LIT-NCLR001 Rev. 2//10 SPECIFICATIONS Materials of Construction Media : NanoCeram® Media Support: Polypropylene, Plastisol O-rings//Gaskets: Neoprene Physical Characteristics Effective Surface Area: 19.7 ft2 (1.8 m2) Electro adsorptive (active) Surface Area: 870,000 ft2 (80,400 m2) Dimensions: 6.4 x 10.75 in (16.3 x 27.3 cm) Weight: Dry: 2.4 lb (1.1 kg) Wet: 6.4 lb (2.9 kg) Operating Conditions Temperature: 39-180oF (4-82oC) pH Range: 4.0 to 9.5 Maximum Operating Pressure: 70 psid (4.8 bar) Suggested Flow Rate: 20 gpm (76 lpm) Maximum Flow Rate: 35 gpm (133 lpm) Virus (MS2) and Bacterial (E. coli) Retention Testing Testing was conducted on NanoCeram-DP (double pleat) cartridges for the purpose of the determining the retention of the MS2 Virus and E. coli bacteria. Twenty five liters of the MS2 or the E. coli suspension were passed through a cartridge at 4 gpm @ 7 psid. The data are scaled to match flow rates of a standard size LR-19 Filter Cartridge. Test Flow Rate GPM MS2 inlet Concen- tration PFU//mL1 MS2 Removal LRV2 E. Coli input Con- centration CFU//mL3 E. Coli Removal LRV2 1 4 1.1x106 >6 1.8 x 106 7.6 2 4 1.1x106 >6 1.8 x 106 7.6 3 4 1.1x106 >6 1.8 x 106 7.4 Avg. 4 1.1x106 >6 1.8 x 106 7.5 NanoCeram-LRTM Series 1) Plaque Forming Units 2) Log Reduction Value 3) Colony Forming Units Ordering Information Part No: LR-19 WATER FLOW RATE LR-19 CARTRIDGE
Most popular related searches