Monarch Instrument

Nova-Pro - Brochure

Description Features  • 1/8 DIN sized  • 5 Digit LED display  • 5 to 999,990 RPM range  • Universal sensor inputs  • User configurable with front panel push but-tons or Optional PM Remote Software  • View real-time data on PC*   • Store data in Excel File in real-time*  • Universal A/C power 100 to 240 Vac,      50/60Hz or optional 12 or 24Vdc power  • Optional 4-20mA or 0-5Vdc scalable output  *Requires Optional PM Remote Software ACT-3X Programmable Panel Tachometer/Totalizer The  ACT-3X  is  a  powerful  NIST  calibrated  fully programmable  tachometer  and  totalizer.  It accepts  inputs  from  all Monarch  speed  sensors or from any standard TTL generating device. The unit operates  from  120/240Vac  input power or from  12  or  24Vdc  input  power  (optional). Programming  is easily performed  through  the 5 front  panel  push  buttons  or  using  the  optional PM Remote Software. Set up  for  single channel monitoring  or  use  the  auxiliary  second  channel input.    Programmable  scale  factor  with  menu selection  for  multiple  pulses  per  revolution, linear rates, totalization, single event trip speeds and rate of change  in rpm. A TTL pulse repeater output is standard. Options  include:  0-5Vdc or 4-20mA  isolated  (or non-isolated)  outputs  and  2  Form  C programmable  relay  outputs.  Available communication  options  include:  bi-directional  RS232C, USB or Ethernet. When used with  the optional   PM   Remote  Software,   the communication  options  allow  for  remote configuration,  real-time  view of data, and data streaming directly into Microsoft Excel™.  Typical Uses • Process monitoring  • Research and development  • Field testing  • Engine performance  • Interface to PLC’s • Marine testing  • Trip speed testing  • Rate of change (speed)  • Single event capture  • Predictive maintenance  Made in USA RoHS NIST PM Remote Software ACT-3X Programmable Panel Tachometer/Totalizer PM  (Panel Meter)  Remote  Software  is  a Windows™ based  software  application  that  allows  the  user  to customize  the  configuration  of  the  ACT-3X tachometer/totalizer.  Set  the  mode  of  operation  to RPM,  RPS,  Frequency,  Totalization,  Single  Event Capture or Rate of Change and  select  the  input  scale (pulses per revolution). In addition, the decimal places displayed can be selected as well as the output scale of the optional analog output modules.   The  two  alarm  setpoints  are  easily  configured within the Alarms  tab. From  the Advanced  tab,  the user can set the input pulse trigger and optional output pulse to be positive or negative. Complete unit  configurations can  be  saved  to  disk  and  quickly  reloaded  or transferred to other ACT-3X units.  Real-time data can be  displayed  directly  on  the  PC  along with Min  and Max  values.  Data  can  be  streamed  directly  into Microsoft  Excel™  with  one  simple  mouse  click.  PM Remote  Software  is  supplied  on  CD  and  is  included when  purchasing  the  optional  3  foot  programming cable  (1/8”  (3.5mm)  phone  plug  to  USB  connector).  Units  ordered  with  USB,  RS232  or  Ethernet  do  not include an interface cable. Configuring Basic Features Real-time display 2 Rear Panel Configuring Advanced Features Configuring Alarms  ACT-3X Programmable Panel Tachometer/Totalizer Specifications 3 Speed Range:  5 to 999,990 RPM (single pulse per revolution),  0.5 to 999,990 RPM (10 pulses per revolution). Speeds below 5 RPM are possible with multiple pulses per revolution Input Frequency Range:  0.083 Hz to 250 kHz Totalizer/Counter:  Display Range: 0.001 to 99,999 (Only top 5 digits are shown for 100,000-999,990) Max # of counts = 16,777,216 even with 0.001 scale Input Configuration:  Universal Inputs: 1 to 9,999 pulses per revolution, front panel push button programmable TTL input and 1.1V to 50vac signals,  Opt: -1 to – 50Vdc Accuracy:  ±0.001% of reading or ±1 displayed resolution (Standard Gate), ±0.01% of reading or ±1 displayed resolution (Fast Gate). Resolution:  Up to 0.001 RPM, 10 RPM (100,000 to 999,990 RPM). Display:  5 digit, 0.56” (14 mm) high red LED. Display Update:  Menu Selectable between: 0.5 second above 120 RPM, 1 second above 60 RPM and 1.5 seconds above 40 RPM. Max Measurement Rate:  Up to 100 times per second (Standard Gate) or up to 1000 (Fast Gate) dependent on input frequency. Input must be  > measurement rate.  Scaling:  Programmable scaling: 0.0001 to 9999.9 (front panel push button programmable). Decimal Point:  User Selectable (0-3) decimal places max (front panel push button programmable). Memory:   Maximum, minimum and last reading recall from front panel push buttons. Dimensions:  1/8 DIN by 4.5” (114 mm) deep. Panel cutout: 3.58” x 1.74” (91 x 44mm) Input Power:  Standard: 100 - 240 Vac ±10%, 50/60 Hz      Optional:  12 or 24 Vdc ±20%, Isolated, 6.0 Watts.  Inputs:  Universal input for optical, proximity, two wire or three wire magnetic, infrared or laser sensors. TTL input or 1.5 Vac to 50 Vac input. Standard input is 1 pulse per revolution.  Sensor Excitation:  5Vdc or optional 12Vdc or 24Vdc to sensor. Recommended Sensors:  Optical  - Monarch ROS-W, ROS-P-25, ROS-HT-W-25, ROSM-5W Proximity  - Monarch P5-11 Magnetic  - Monarch M-190W or MT-190W Infrared  - Monarch IRS-W Laser  - Monarch ROLS-W, SLS-115/230 Inductive  - Gas Engine GE-200 Pulse Repeater Output:  Standard, 0 to 5 V TTL compatible. One pulse out for each pulse in. Menu selectable polarity. Communications:   Bi-directional RS232C, USB or Ethernet interface. Analog Output:  Voltage (AO): 0 to 5 Vdc, 5mA max load (isoloated or non-isolated) or Current (IO): 4 to 20mA, 500? max load. (isolated or non-isolated), 1 to 5Vdc possible using 250? resistor) 16 bit resolution. Front panel push button programmable for full scale and offset RPM ranges.  Alarm Capability:  Two alarm set points:  High or Low alarm limits, Latching or Non-Latching, Front panel push button programmable Hysteresis, dead band and low limit lockout are programmable, Relays can be set as failsafe. Alarms can be reset Manually or Automatically.     Remote reset via auxiliary input. Alarm Outputs:   Two Form C relay contacts, rated 1A at 115Vac or 230Vac Remote Programming:   Unit can be remotely programmed using optional communications interface and PM Remote Software. Environmental:  Indoor use only, Installation category II per IEC 664 Temperature: -10°C to 50°C operating per IEC 61010-1 Humidity: Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 40°C. Electrical Safety:   Meets EN61010-1:2001, EC low voltage directive 72/23/EEC and 89/336/EEC RoHS NIST ACT-3X Programmable Panel Tachometer/Totalizer Ordering Information To specify your ACT-3X, select options from the list below. Insert your selection in the boxes above to complete your model number.  6180-031     USB Programming Cable and Software (supplied on CD)   3 ft. Programming Cable, 1/8” (3.5mm plug to USB) and Windows™ compatible PM Remote Software Package. Allows user configuration of operation mode, analog output scaling, decimal places, display update rate and pulses per input. View real time data in digital format and/or through Microsoft® Excel. 1064-2022-001     Wire (per foot)    3-wire shielded Sensor Cable, bulk lengths for any sensor. Specify Total Length. 6180-070     T-5     Reflective Tape - 5 foot roll, 0.5 inch wide 6180-079     T-5WP     Waterproof reflective tape (honeycomb pattern) - 5 foot roll, 1 inch wide 6180-CAL     Calibration - N.I.S.T.    N.I.S.T. Traceable Certificate of Calibration (For re-calibration only). New units include N.I.S.T. calibration Accessories 6180-030     ROLS-W    Remote Optical Laser Sensor with 8 foot cable, 4 tinned leads, mounting bracket with jam nuts and 12 inches of T-5 tape. 6180-056     ROS-W     Remote Optical Sensor with 8 foot cable, mounting bracket and 12 inches of reflective tape 6180-057-25     ROS-P-25     Remote Optical Sensor with 25 foot cable, mounting bracket and 12 inches of reflective tape 6180-058-25     ROS-HT-W-25    Same as 6180-056 for high temperature applications to 257°F (125°C) with 25 foot cable 6180-013     P5-11     Proximity Sensor with 6 foot cable 6180-018     MT-190W     Magnetic Trigger Sensor/Amplifier with 8 foot cable 6180-012     M-190W     Magnetic Sensor with 8 foot cable 6180-019     GE-200     Gasoline Engine Electromagnetic Inductive Sensor and amplifier with 23 feet of cable 6180-021     IRS-W    Infrared Sensor with 8 foot cable, tinned wires and mounting bracket Sensors 4 February 2010