Aqualabo
ODEON - Advanced Digital Meter Handheld Instrumentation Data Sheet
PONSEL MESURE – AQUALABO GROUP 35 Rue Michel MARION – 56850 CAUDAN Tél.: +33 (0)2.97.89.25.30 - Fax :+33 (0)2.97.76.55.72 Email :ponsel@ponsel.fr - www.ponsel.fr Datasheet : ODEON Range Applications : Wastewater, drinking water natural water… MAJ : July 2011 Advanced Digital Meter ODEON® Reliability, simplicity and flexibility . pH/ORP . Dissolved Oxygen . Conductivity .Turbidity OPTOD Optical Technology ???? ALWAYS READY TO MEASURE : Digital plug and play probes ???? ALWAYS CONFIDENCE : Autodiagnostic, status always displayed, GLP compliance ???? SIMPLICITY : 4’ display and intuitive menus ???? HIGH PERFORMANCES : Mono/Multiparameters - 8 Mo Memory (100 000 data) ? FIELD INTRUMENTATION : IP67 Access to high performances with the PONSEL ODEON® Digital Handheld Instrumentation. A real combination of simplicity, flexible, reliability and reduced maintenance technologies, the ODEON Meters offer you a total confidence in your readings in laboratory and field conditions. This range of 6 ODEON Meters are available in the Classic Line (single channel meters), Open Line (Versatile single channel meters), X Line (Versatile bi-channels Meters) to meet all yours requirements PONSEL MESURE – AQUALABO GROUP 35 Rue Michel MARION – 56850 CAUDAN Tél.: +33 (0)2.97.89.25.30 - Fax :+33 (0)2.97.76.55.72 Email :ponsel@ponsel.fr - www.ponsel.fr Datasheet : ODEON Range Applications : Wastewater, drinking water natural water… MAJ : July 2011 ???? ODEON® METERS Classic Line, One Line and X Line Models Classic Line Open Line pH/ORP T Oxygen / T Conductivity Turbidity 0 4000 NTU 0-4500 mg/L One X Probes compatibility PH/ORP/T X X X OPTOD X X X Conductivity X X X Turbidity X X X Probe Channels 1 2 Digital Technology CLASSIC Possibility to upgrade to OPEN Technology OPEN Memory 100 000 points (with sample ID, User ID, date and time..) Data Management GLP compliance ID Samples, Campaigns, Users : Alphanumeric, 10 words max, 20 users max Reading/Recording 3 modes : Manual, interval,continuous Sensor status Indicator Yes Autodiagnostic Yes Display Large backlighted graphic LCD 4’ display, 240 x 320. Automatic switch in economic mode. With date, time, user and sample user, °C, status, pressure. Simultaneous display of 1 to 7 parameters (max) Power supply 4 AA batteries or chargeable batteries (battery charger needed) Autonomy 200 hours with standard batteries (in economic mode) Interfaces -USB -RS 485 interface to probes (1 or 2) -External 12 V battery -Charger Box PC/ABS Dimension - Weight 196 x 121x 46 mm - 400 g Protection Outdoor instrument, IP67, Watertight Operate temperature - 10 to + 60°C Storage temperature - 25 to + 65°C Operate hydrometry > 80% 7 buttons to access to all functions Ergonomic design for all hand Wide graphical screen 4’ 320 x 240 backlighted Inserts for wrist-loop or strap Watertight all-purpose connectors Clic-Loc™ Plug 8 Mb memory IP 67 Watertight Probe 1 Probe 2 (X Line only) -USB cable -Loader supply -External supply ? User friendly Intuitive menus - No user manual required ???? Comfortable and easy to read Large 4’ backlighted display ???? PC USB connection ???? Easy handling in all situations Only 5 buttons for all functions ???? High autonomy Low Power technology One X Classic LINE Open LINE Models PONSEL MESURE – AQUALABO GROUP 35 Rue Michel MARION – 56850 CAUDAN Tél.: +33 (0)2.97.89.25.30 - Fax :+33 (0)2.97.76.55.72 Email :ponsel@ponsel.fr - www.ponsel.fr Datasheet : ODEON Range Applications : Wastewater, drinking water natural water… MAJ : July 2011 ???? PONSEL Digital probes ? No Calibration, No membrane, No electrolyte, No drift ? No cross sensitivity with pH 1 -14, CO2, H2S, SO2 ? Real Time Temperature, Salinity and Pressure Compensation ? Fast response sensor ? No O2 consumption : Precision in low O2 concentrations ? ASTM International Method D 888 – 05 compliance DISSOLVED OXYGEN OPTOD® Optical Luminescence Technology TURBIDITY IR Nephelometry 0 – 4 000 NTU ; 0-4500 mg/L PONSEL OPTOD® Luminescence technology Light Reactive caps Light Emission CONDUCTIVITY PONSEL C4E ? IR Sensor – Optical fiber technology ? Precise and accurate measurements ? Calibration in mg/L ? No sampling – real turbidity value with direct measurement ? ISO 7027 compliance ? Conductivity / Salinity / Temp sensor ? C4E electrode ? Temperature compensation ? Robust field probe ? No maintenance ? Plug and Play digital probes Your probe is immediately ready to use ???? High fiability and confidence in your readings Autocheck, status and calibration autodiagnostic ???? Robust probes Outdoor use design for Laboratory, wastewater, natural water, fishfarming applications. ???? Flexible and smart probes Calibration and history data inside ???? Ultra low power probes For long term campaigns ???? PONSEL Probes 50 years experience in probes manufacturing pH / ORP ? pH/ORP/Temp sensor ? PONSEL "PLASTOGEL"® Plasticized electrolyte ? Temperature compensation ? Robust field probe ? Cost effective : only pH/ORP Cartridge technology PONSEL MESURE – AQUALABO GROUP 35 Rue Michel MARION – 56850 CAUDAN Tél.: +33 (0)2.97.89.25.30 - Fax :+33 (0)2.97.76.55.72 Email :ponsel@ponsel.fr - www.ponsel.fr Datasheet : ODEON Range Applications : Wastewater, drinking water natural water… MAJ : July 2011 ? Datasheets Probes pH/ORP T Oxygen / T Conductivity / T Turbidity / T Applications Laboratory and field conditions Laboratory and field conditions Laboratory and field conditions Laboratory and field conditions Compatibilty Wastewater, drinking water, seawater, rivers, natural water….. Wastewater, drinking water, seawater, rivers, natural water….. Wastewater, drinking water, seawater, rivers, natural water….. Wastewater, drinking water, seawater, rivers, natural water….. Sensors pH, ORP, Temperature OPTOD, Temperature Conductivity, Salinity, temperature Turbidity, Temperature Dimension (D x L) 23 x 159 mm 25 x 146 mm 27 x 177 mm 27 x 170 mm Standard Cable lenght 3 m 3 m 3 m 3 m Weight with 3 m cable 350 g 450 g 350g 300 g Protection Class IP68 IP68 IP68 IP68 Operate temperature -10°C – 50°C -10°C – 50°C -10°C – 50°C -10°C – 50°C Temperature sensor CTN CTN CTN CTN Interface communication Modbus RS 485 Modbus RS 485 Modbus RS 485 Modbus RS 485 Material PVC Inox 316 L PVC PVC PMMA Spare pH/ORP Cartridge DOdisk® - - Electronic Warranty 2 years 2 years 2 years 2 years parameters pH ORP Dissolved Oxygen Conductivity Salinity Turbidity Range 0,00 – 14,00 pH -1000,0 mV +1000,0 mV 0,00 – 20,00 mg/L 0 – 200% SAT 4 ranges 0-200,0 µS/cm 0 –2000 µS/cm 0,00 –20,00 mS/cm 0,0 –200,0 mS/cm 0 - 4000 NTU 4 ranges : 0,0 – 50,0 NTU 0,0 – 200,0 NTU 0 – 1000 NTU 0 – 4000 NTU Scale switch - - - Manual/Automatic Manual/Automatic Resolution 0,01 pH 0,1 mV 0,01 mg/L 1%SAT 0,01 to 1 µ/mS/cm 0,1 to 1 NTU -mg/L Accuracy ± 0,1 pH ± 1 mV ± 0,1 mg/L ± 1 % ± 1 % of the full scale < 5 % of the full scale NTU Compensation Temperature - Pressure, temp, salinity (Mode : Off, Manual, Automatic) Temperature Temperature Measurement principe plasticized PONSEL "PLASTOGEL"®. electrolyte Ag/AgCl reference Platinum electrode Ag/AgCl reference PONSEL OPTOD® optical luminescence technology ASTM D888 – 05 Complinace C4E Technology 4 electrodes (2 platinum and 2 graphite) IR 90° technology ISO 7027 compliance Response time t90 Full range : 0 – 100% < 5 s < 5 s < 1 s < 5 s < 5 s ? Standard Set Meter 1 Meter ODEON Classic, ODEON OPEN ONE or ODEON X (with 4 AA batteries) Probes 1, 2, 3 or 4 Digital PONSEL probes with 3 meters cables Charger 1 230 V Charger ODEON PC Cable 1 Standard solutions 125 mL standard solutions (according parameters) Carrying case Outdoor case, plastic case, shockproof, lightweight; for 2 probes, PC cable, Charger and and 4 bottles of standard solution(125 ml) PC Software Wintek Viewer ? Accessories/Options ? Standard solutions (125 mL) : pH : 4,01-7,01-10,01 ORP : 240 mV Conductivity : 84 µS/cm, 1413 µS/cm et 12 880 µS/cm / Turbidity : Formazine ? Cable lengths : 7 m / 15 m (other on demand) ? Carrying case ? Software : WINTEK ? ODEON Upgrade : Classic to Open line ? 12 V external power supply cable
Most popular related searches
