Parker Balston - Analytical Gas Systems

Parker Balston - High Purity Nitrogen Generators - Brochure

Products for Chromatography161-800-343-4048 www.labgasgenerators.comNitrogen Generators with Research Grade Purity? Produce a continuous supply of high purity nitrogen gas from existing compressed air? Eliminate the need for costly, dangerous, inconvenient nitrogen cylinders in the laboratory? Compact design frees up valuable laboratory floor space? Offers long term cost stability - uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concern? Ideal for carrier gas applicationsThe Parker Balston® Models HPN2 and UHPN2 Series Nitrogen Generators are com-pletely engineered to transform standard compressed air into 99.99% or 99.9999% nitrogen, exceeding the specification of UHP cylinder gas. These systems can produce up to 1.1 lpm of UHP nitrogen gas and up to 2.0 lpm of research grade purity nitrogen gas. Nitrogen is produced by utilizing a combination of state-of-the art purification technologies and high efficiency filtration. Pressure swing adsorption removes O2, CO2, and water vapor. A cata-lyst module is incorporated in the UHPN2 Series to oxidize hydro-carbons from the inlet air supply. High efficiency coalescing prefilters and a 0.01 micron (absolute) membrane filter is also incorporated into the design of the generators. The Parker Balston UHPN2 and HPN2 Series Nitrogen Generators are engineered and packaged in a small cabinet to fit on or under any bench-top. The systems eliminate the need for costly, inconvenient high pressure nitrogen cylinders. Typical applications include GC carrier and make-up gas and low flow sample concentrators.Flow TableModel UHPN2-1100Inlet Air Max Outlet Max Outlet Pressure (psig) Flow (cc/min.) Pressure (psig)Models HPN2-1100 and UHPN2-1100 125 1100 85110 1000 75100 900 6590 800 6080 700 5070 600 4560 500 35Model HPN2-200075-120 2000 90Products for Chromatography171-800-343-4048 www.labgasgenerators.comNitrogen Generators with Research Grade PurityPrincipal SpecificationsNotes:1 Models HPN2-1100 and HPN2-2000 do not remove hydrocarbons and carbon monoxide.2 Purity specification for Nitrogen does not include Argon concentration.3 Power Consumption is as follows: Model HPN2-1100 = 25 Watts Model UHPN2-1100 = 700 Watts Model HPN2-2000 = 25 Watts.4 Refer to voltage appendixfor electrical and plug configurations for outside North America.Ordering Information call 800-343-4048, 8 to 5 ESTModel HPN2-1100, UHPN2-1100 HPN2-2000Max Nitrogen flow rate See Flow Table 2 lpmNitrogen Purity 99.9999% 99.99%Max Nitrogen output pressure See Table 90 psigCO concentration < 1 ppm NACO2 concentration < 1 ppm < 1 ppmO2 concentration < 1 ppm < 100 ppmH2O Concentration < 1 ppm < 2 ppmHydrocarbon concentration (1) < 0.1 ppm NAArgon concentration (2) 0.9% 0.9%Min/Max inlet pressure 60 psig/125 psig 75 psig/120 psigRecommended inlet temperature 78°F (25°C) 78°F (25°C)Ambient operating temperature 60°F-100°F (16°C-38°C) 60°F-100°F (16°C-38°C)Max air consumption 42 lpm (1.5 scfm) 42 lpm (1.5 scfm)Inlet connection 1/4” NPT (female) 1/4” NPT (female)Outlet connection 1/8” compression 1/8” NPT compressionElectrical requirements (3, 4) 120 VAC/60 Hz 120 VAC/60 HzDimensions 12” w x 16” d x 35” h 12” w x 16” d x 35” h (30cm x 41cm x 89cm) (30cm x 41cm x 89cm)Shipping Weight 110 lbs. (50 kg) 110 lbs. (50 kg)Description Model NumbersHigh Purity Nitrogen Generator HPN2-2000Ultra High Purity Nitrogen Generator HPN2-1100 and UHPN2-1100Purity Indicator/Scrubber 72092Optional Prefilter Scrubber Assembly 76080Pressure Regulator W-425-4032-000Maintenance Kit MK7692, MK7694, MKHPN22000Installation Kit for All Models IK7694Preventive Maintenance Plan HPN2-1000-PM, UHPN2-1100-PM, HPN2-2000-PMExtended Support with 24 Month Warranty HPN2-1100-DN2, UHPN2-1100-DN2, HPN2-2000-DN2Products for Spectroscopy251-800-343-4048 www.labgasgenerators.comThe Parker Balston® 76-97NA and 76-98NA UHP Nitrogen Genera-tors can produce 5-12 lpm of ultra high purity nitrogen gas. These systems are completely engineered to transform standard compressed air into 99.9999% of 99.995% pure nitrogen, exceeding the specifica-tion of UHP cylinder gas and dew-ars. Nitrogen is produced by utiliz-ing a combination of state-of-the-art purification technologies and high efficiency filtration. Pressure swing absorption is utilized for the re-moval of 02, CO2, and water vapor. A catalyst module is incorporated in the 76-98NA to oxidize hydrocar-bons from the inlet air supply. The generators also have a combination of high efficiency prefilters and a 0.01 micron (absolute) membrane filter incorporated into their design. The Parker Balston UHP Nitrogen Generators are engineered and packaged in a laboratory cabinet to fit nearly any laboratory. The systems eliminate the needs for costly, inconvenient high pressure nitrogen cylinders or dewars. The 76-97NA and 76-98NA are ideal for ICP Purge gas applications. ? Produces a continuous supply of ultra high purity nitrogen gas from existing compressed air? Eliminates the need for costly, dangerous, inconvenient nitrogen cylinders or dewars in the laboratory? Extends ICP Analysis into far-UV range below 170 (nm)? Compact design frees up valuable laboratory floor space? Offers long term cost stability - uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concernModel 76-98NA Nitrogen GeneratorICP Spectrometer Nitrogen GeneratorApplicationsOther applications include high flow GC carrier gas needs, DNA Synthesis and Sequenc-ing Equipment, Mocon Moisture Analyzers, Circular Dichroism and Gel Permeation needs.Products for Spectroscopy261-800-343-4048 www.labgasgenerators.comOrdering Information Flow Table@ 99.9999% PurityInlet Air Pressure Max Outlet Flow Max Outlet Pressure (psig) (lpm) (psig) Models 76-97NA and 76-98NA120 5 83 110 5 73 100 5 63 90 4 62 80 4 51 70 2 50 60 2 42Inlet Air Pressure Max Outlet Flow Max Outlet Pressure (psig) (lpm) (psig) Models 76-97NA and 76-98NA120 12 60 110 12 55 100 12 45 90 10 45 80 8 40 70 8 35 60 6 33Principal SpecificationsNotes:1 Model 76-97NA does not remove hydrocarbons.2 Purity specification for Nitrogen does not include Argon concentration. 3 Power Consumption is as follows: Model 76-97NA = 10 Watts, Model 76-98NA = 1 KW4 Refer to voltage appendix for electrical and plug configurations for outside North America.ICP Spectrometer Nitrogen GeneratorFlow Table@ 99.995% PurityModel Numbers Description 76-97NA and 76-98NA Ultra High Purity Nitrogen Generator 76-97-PM, 76-98-PM Preventive Maintenance Plan76-97-DN2, 76-98-DN2 Extended Support with 24 Month WarrantyModel 76-97NA/76-98NANitrogen Purity 99.995% and 99.9999%Max Nitrogen Output Pressure See Table (above)CO Concentration < 1 ppmCO2 Concentration < 1 ppmO2 Concentration < 1 ppmH2O Concentration < 2 ppmHydrocarbon Concentration (1) < 0.1 ppm Argon Concentration (2) 0.9% Min/Max Inlet Pressure 60 psig/120 psig Recommended Inlet Temperature 78°F (25°C) Ambient Operating Temperature 60°F-100°F (16°C-38°C)Average Air Consumption 3.0 scfmInlet Connection 1/4” NPTOutlet Connection 1/8” NPT, convertible to 1/4” NPT Electrical Requirements (3, 4) 120 VAC/60 HzDimensions 41”h x 25”w x 25”d (104cm x 64cm x 64cm) Shipping Weight 500 lbs (227 kg)Products for LC/MS & Evaporation381-800-343-4048 www.labgasgenerators.comLow and Mid Flow Nitrogen Generators? Recommended and used by all major LC/MS manufacturers? Eliminates the need for costly, dangerous, inconvenient nitrogen cylinders in the laboratory? Models N2-04, N2-14, N2-22, N2-35 require no electricity? Compact design frees up valuable laboratory floor space? Phthalate-free, no organic vapors? Unlike PSA technology, membrane will not suppress corona needle discharge.Parker Balston® Low Flow Nitrogen Generators include models N2-04, N2-14, N2-14A that produce up to 61 SLPM of compressed nitrogen, on-site. The Parker Balston® Mid-Flow Nitrogen Generators include models N2-22, N2-22ANA, N2-35, and N2-35ANA that produce 132 SLPM of compressed nitrogen, on-site. The purity level of the nitrogen stream is defined by the user, for the application, and may range from 95% to 99.5%. Low Flow Model N2-14ANA and Mid Flow Models N2-22ANA and N2-35ANA Nitrogen Generators include an oxygen analyzer which monitors the oxygen concen-tration of the nitrogen stream. An audible alarm signals high or low oxygen concentrations. Parker Balston Nitrogen Generators are complete systems engineered Model N2-22 Mid Flow Membrane Nitrogen Generatorto transform standard compressed air into nitrogen at safe, regulated pressures, on demand, without the need for operator attention. The systems eliminate the need for costly, dangerous dewars and cylinders in the laboratory. Nitrogen is produced by utilizing a combination of filtration and membrane separation technologies. A high efficiency prefiltra-tion system pretreats the compressed air to remove all contaminants down to 0.01 micron. Hollow fiber membranes subsequently separate the clean air into a concentrated nitrogen output stream and an oxygen enriched permeate stream, which is vented from the system. The combination of these technologies produces a continuous on demand supply of pure nitrogen.Typical applications include: LC/MS, nebulizer gas, chemical and solvent evaporation, instrument purge and supply, evaporative light scattering detector use (ELSD), and sparging. This Technology Features Advanced HiFluxx FiberProducts for LC/MS & Evaporation391-800-343-4048 www.labgasgenerators.com 145 125 110 100 90 80 70 6099.5 19 29 16 25 14 22 13 20 12 18 10 16 9 13 17 1199 29 44 25 37 22 33 20 30 18 27 15 23 13 20 11 1798 44 66 38 57 34 51 30 46 27 41 24 36 20 30 17 2697 59 83 50 74 45 65 40 57 36 52 31 46 26 40 23 3596 73 109 63 94 56 84 50 75 45 67 39 59 32 50 27 4295 88 131 177 114 69 102 61 90 55 81 48 71 41 60 35 52Principal SpecificationsOrdering Information for assistance, call 800-343-4048, 8 to 5 Eastern Standard Time 145 125 110 100 90 80 70 6099.5 – 11 – 10 – 9 – 8 – 7 – 6 – 5 – 499 6 18 5 16 5 15 4 13 4 11 3 10 3 8 2 798 11 29 10 25 9 25 8 20 7 18 6 16 5 13 4 1197 15 40 13 34 13 33 10 27 9 25 8 21 7 18 6 1596 20 50 17 43 16 42 13 34 12 31 10 26 9 22 7 1995 24 60 21 52 20 51 17 42 15 37 13 32 11 28 9 24Flow measured in SLPM at indicated Operating Pressure, psig. Flows for Model N2-04 printed in black, flows for Models N2-14 and N2-14A in red.Nitrogen Purity / Flow ChartFlow measured in SLPM at indicated Operating Pressure, psig. Flows for Model N2-22, N2-22A printed in black, flows for Models N2-35, N2-35A in red.Nitrogen Purity / Flow ChartDescription Galvanic Cell Annual Installation Kit Preventive Extended Support with Maintenance Kit Maintenance Plan 24 Month WarrantyN2-04 N/A MK7840 IK7572 N2-04 -PM N2-04-DN2N2-14 N/A MK7572C IK7572 N2-14-PM N2-14-DN2N2-14ANA 72695A MK7572C IK7572 N2-14A-PM N2-14A-DN2N2-22, N2-35 N/A MK7572C IK7572 N2-22-PM, N2-35-PM N2-22-DN2, N2-35-DN2N2-22ANA, N2-35ANA 72695A MK7572C IK7572 N2-22A-PM, N2-35A-PM N2-22A-DN2, N2-35A-DN2Models N2-04, N2-14, N2-14ANA, N2-22, N2-22ANA, N2-35 and N2-35ANA Nitrogen Purity 95.0% - 99.5%Atmospheric Dewpoint -58°F (-50°C)Suspended Liquids NoneParticles > 0.01µm NoneCommercially Sterile YesPhthalate-free YesHydrocarbon-free YesMin./Max. Operating Pressure 60/145 psigMax. Press. Drop @ 99% N2 Purity, 125 psig 10 psig Recommended Ambient Operating Temperature 68°F (20°C)Max. Inlet Air Temperature 110°F (43°C)Inlet/Outlet Ports 1/4” NPTElectrical Requirements N2-04, N2-14, N2-22, N2-35 None N2-14ANA, N2-22ANA, N2-35ANA 120 VAC/60 Hz/25 WattsShipping Weight N2-04 42.5 lbs (19 kg) N2-14 75 lbs (34 kg) N2-14ANA, N2-22, N2-22ANA 80 lbs (36 kg) N2-35, N2-35ANA 90 lbs (41 kg) Oxygen Analyzer Included with Model N2-14ANA, N2-22ANA, N2-35ANADimensions, N2-04 16.1”h x 10.7”w x 13.4”d (40.9cm x 27.2cm x 34cm) Dimensions, N2-14, N2-14ANA, N2-22, N2-22ANA, N2-35, N2-35ANA 51.5”h x 18”w x 16.2”d (130.8cm x 45.7cm x 41.1cm)Products for LC/MS & Evaporation401-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen Generators? Recommended and used by all major LC/MS manufacturers? Eliminates the need for costly, dangerous, inconvenient nitrogen cylinders in the laboratory? Models N2-45, N2-80, and N2-135 require no electricity? Compact design frees up valuable laboratory floor space? Phthalate-free, no organic vapors? Unlike PSA technology, membrane will not suppress corona needle discharge.Parker Balston® High Flow Nitrogen Generators include models N2-45, N2-80, N2-135 that produce up to 467 SLPM of compressed nitrogen, on-site. The purity level of the nitrogen stream is defined by the user, for the application, and may range from 95% to 99.5%. High Flow Model N2-45ANA, N2-80ANA, and N2 135ANA Nitrogen Generators include an oxygen analyzer which monitors the oxygen concentration of the nitrogen stream. An audible alarm signals high or low oxygen concentrations. Parker Balston Nitrogen Generators are complete systems engineered to transform standard compressed air into nitrogen at safe, regulated pressures, on demand, without the need for operator attention. The systems eliminate the need for costly, dangerous dewars and cylinders in the laboratory. Nitrogen is produced by utilizing a combination of filtration and membrane separation technologies. A high efficiency prefiltration system pretreats the compressed air to remove all contaminants down to 0.01 micron. Hollow fiber membranes subsequently separate the clean air into a concentrated nitrogen Model N2-135 High Flow Membrane Nitrogen Generatoroutput stream and an oxygen enriched permeate stream, which is vented from the system. The combination of these technologies produces a continuous on demand supply of pure nitrogen.Typical applications include: LC/MS, nebulizer gas, chemical and solvent evaporation, instrument purge and supply, evaporative light scattering detector use (ELSD), and sparging. Products for LC/MS & Evaporation411-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen GeneratorsPrincipal SpecificationsOrdering Information for assistance, call 800-343-4048, 8 to 5 Eastern Time 145 125 110 100 90 80 99.5 67 100 133 55 83 110 47 71 94 39 59 78 33 50 66 27 41 5499 92 138 183 74 112 149 63 95 127 53 79 106 44 66 89 35 53 71 98 129 194 258 106 159 212 89 134 179 73 110 147 62 93 124 50 75 101 97 163 244 325 132 198 264 113 169 226 94 141 187 79 119 159 65 97 130 96 200 300 400 160 240 320 137 205 274 114 171 228 97 145 194 80 119 159 95 233 350 467 187 281 374 160 241 321 134 201 268 111 167 222 90 135 180Flow LPM (liters per minute), at 68°F (25°C) inlet air temperature and operating pressure, PSIG.Flows printed in black are for Models N2-45 and N2-45AFlows printed in red are for Models N2-80 and N2-80AFlows printed in green are for Models N2-135 and N2-135ANitrogen Purity / Flow ChartDescription Galvanic Cell Carbon Maintenance Installation Preventive Extended Support with Tower Kit Kit Maintenance Plan 24 Month WarrantyN2-45 N/A 75344 75478 IK75880 N2-45-PM N2-45-DN2N2-45ANA 72695A 75344 75478 IK75880 N2-45A-PM N2-45A-DN2N2-80 N/A 75344 75478 IK75880 N2-80-PM N2-80-DN2N2-80ANA 72695A 75344 75478 IK75880 N2-80A-PM N2-80A-DN2N2-135 N/A 75344 75478 IK75880 N2-135-PM N2-135-DN2N2-135ANA 72695A 75344 75478 IK75880 N2-135A-PM N2-135A-DN2Model N2-45, N2-80, N2-135, N2-45ANA, N2-80ANA, and N2-135ANANitrogen Purity 95.0% - 99.5%Atmospheric Dewpoint -58°F (-50°C)Suspended Liquids NoneParticles > 0.01µm NoneCommercially Sterile YesPhthalate-free YesHydrocarbon-free YesMin./Max. Operating Pressure 60/145 psigMax. Press. Drop @ 99% N2 Purity, 125 psig 10 psig Recommended Ambient Operating Temperature 72°F (22°C)Max. Inlet Air Temperature 110°F (43°C)Inlet/Outlet Ports 1/2” NPTElectrical Requirements N2-45, N2-80, N2-135 None N2-45ANA, N2-80ANA, N2-135ANA 120 VAC/60 Hz/25 WattsShipping Weight N2-45, N2-80, N2-135 250 lbs (114 kg) N2-45ANA, N2-80ANA, N2-135ANA 250 lbs (114 kg)Oxygen Analyzer Included with Model N2-45ANA, N2-80ANA, N2-135ANA Dimensions 67”h x 24”w x 20”d (140cm x 61cm x 50cm)Products for LC/MS & Evaporation421-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen Generators? Lower cost...eliminates the need for costly gas cylinders? Complete package with prefilters, final filters, and receiving tank? Compact - frees up valuable floor space? Eliminates unexpected shutdowns due to a “bad” or empty cylinder? Hassle-free, easy to install, easy to operate? Safe and reliableParker Balston® Monobed Nitrogen Generators produce up to 99.95% pure, compressed nitrogen at dew-points to -70°F (-21°C) from nearly any compressed air supply. The generators are designed to continu-ally transform standard compressed air into nitrogen at safe, regulated pressures without operator atten-tion.Parker Balston PSA Nitrogen Generators utilize a combination of filtration and pressure swing adsorption technologies. High efficiency prefiltration pretreats the compressed air to remove all contaminants down to 0.1 micron. Air entering the generator consists of 21% oxygen and 78% nitrogen. The gas separation process prefer-entially adsorbs oxygen over nitro-gen using carbon molecular sieve (CMS). At high pressures the CMS has a greater affinity for oxygen, carbon dioxide, and water vapor Parker Balston Dual Bed Nitrogen Generatorsthan it does at low pressures. By raising and lowering the pressure within the CMS bed, all contami-nants are captured and released, leaving the CMS unchanged. This process allows the nitrogen to pass through as a product gas at pres-sure. The depressurization phase of the CMS releases the absorbed oxygen and other contaminant gases to the atmosphere.The Parker Balston PSA Nitrogen Generators completely eliminate the inconvenience and the high costs of nitrogen Dewars and cylinders. There is no need to depend on out-side vendors for your nitrogen gas supplies. The hassles of changing dangerous, high pressure cylinders, and interruption of gas supplies are completely eliminated. The Balston PSA Nitrogen Generators offer long term cost stability eliminating un-controllable vendor price increases, contract negotiations, long term commitments, and tank rentals. Once the generator is installed, a continuous nitrogen supply of consistent purity is available within minutes from start-up.Products for LC/MS & Evaporation431-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen GeneratorsInstallation consists of simply con-necting a standard compressed air line to the inlet and connecting the outlet to a nitrogen line. Plug the electrical cord into a wall outlet, and the unit is ready for trouble-free operation. This system is designed to operate 24 hours per day, 7 days per week.Once the system is operating, it requires little monitoring. The only maintenance involves changing the coalescing prefilter cartridges and final sterile air filter periodically. The PSA towers do not require any maintenance.An oxygen monitor to measure the oxygen concentration of the nitrogen stream is available as an option. An audible alarm signals high or low oxygen concentrations (determined by the application). The oxygen analyzer is supplied with alarm relay outputs which may be used to signal a remote alarm, open a backup supply or the pro-cess stream, or close the process flow for protection of downstream equipment or processes.Principal Specifications Nitrogen Purity Flow ChartModel AGS200, AGS400Nominal Conditions Feed Pressure 140 psigTemperature 80°FAmbient Pressure 1 Atm.Compressed Air SpecificationsMaximum Pressure 140 psigTemperature Range 60°F - 105°FDewpoint 40°F pressure dewpoint or betterResidual Oil Content TraceParticles <.01 micronAmbient ConditionsTemperature 45°F-90°FAmbient Pressure AtmosphericAir Quality Clean air without contaminantsDimensions 28.5”L x 32.25”D x 76.25”HWeight AGS200 520 lbs (236 kg) AGS400 738 lbs (335 kg)Inlet 1/2” NPTOutlet 1/2” NPT Models AGS200 and AGS400 Flow Rate (SCFH) Flow Rate (SCFH)Model 99.9%, 140 psig 99.99%, 140 psigAGS200 235 47AGS400 470 94 Products for LC/MS & Evaporation441-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen Generators? Lower cost...eliminates the need for costly gas cylinders? Complete package with prefilters, carbon filter, and membrane filter? Compact - frees up valuable floor space? Eliminates unexpected shutdowns due to a “bad” or empty cylinder? Hassle-free, easy to install, easy to operate? Safe and reliable? Expandable modular designParker Balston® High Flow Ni-trosource Nitrogen Generators pro-duce up to 99.5% pure, commer-cially sterile nitrogen at dewpoints to -58°F (-50°C) from a com-pressed air supply. All Membrane Nitrogen Generators include a 0.01 micron membrane filter which ensures the nitrogen is completely free of suspended impurities.Parker Balston High Flow Ni-trosource Nitrogen Generators are one of the most effecient membrane systems available with higher recovery rates and lower operating costs than many other membrane systems.The generators utilize proprietary membrane separation technology. The membrane divides the air into two separate streams: one is 95%-99.5% pure nitrogen, and the other is oxygen rich with carbon dioxide and other trace gases.The generator separates air into its component gases by pass-Parker Balston N2-300 Nitrosource Nitrogen GeneratorApplicationsHigh thru-put LC/MS contract labsSample concentratorsNitrogen supply to analytical labCustom Systems AvailableFlow rates to 2,265 lpmDelivery presssures to customer’s specificationsSkid mounted systems with compres-sor, receiving tank and controls are availableing inexpensive, conventional compressed air through bundles of individual hollow fiber, semi-permeable membranes. Each fiber has a perfectly circular cross sec-tion and a uniform bore through its center. Because the fibers are so small, a great many can be packed into a limited space, providing an extremely large membrane surface area that can produce a relatively high volume product stream.Compressed air is introduced to the center of the fibers at one end of the module and contacts the mem-brane as it flows through the fiber bores. While oxygen, water vapor and other trace gases permeate the membrane fiber and are discharged through a permeate port, the nitro-gen is contained within the hollow fiber membrane, and flows through the outlet port of the module.Water vapor also permeates through the membrane; therefore, the nitrogen product gas is very dry.Products for LC/MS & Evaporation451-800-343-4048 www.labgasgenerators.comHigh Flow Nitrogen GeneratorsPrincipal Specifications - Nitrosource Series The Parker Balston Nitrosource Ni-trogen Generators completely elimi-nate and inconvenient and the high costs of nitrogen Dewars and cylin-ders. There is no need to depend on outside vendors for nitrogen gas supplies. The hassles of changing dangerous, high pressure cylinders and interruption of gas supplies are completely eliminated. The Balston Systems offer long term cost stabil-ity by eliminating uncontrollable vendor price increases, contract negotiation, long term commit-ments and tank rentals. Once the generator is installed, a continuous nitrogen supply of consistent purity is available within minutes from start-up.The Parker Balston Nitrosource Nitrogen Generators are com-plete systems ready to operate as delivered with carefully matched components engineered for easy installation, operation and long term reliability. The generators are free-standing and housed in an attractive cabi-net. Standard features include: high efficiency coalescing prefilters with automatic drains, an activated carbon filter, and a 0.01 micron membrane final filter. Installation consists of simply connecting a standard compressed air line to the inlet and connecting the outlet to a nitrogen line.There is no complicated operating procedure to learn or labor intensive monitoring involved. Simply select the purity your process requires, set the flow and pressure, and within minutes high purity, dry nitrogen is available for useOnce the system is operating, it requires little monitoring. The only maintenance involves changing the coalescing filter cartridges and activated carbon filter periodically. This is a simple ten minute proce-dure.All models also include an oxygen monitor which offers LCD read-outs and remote alarm or chart recorder capabilities. An audible alarm signals high or low oxygen concentrations (determined by the application). The oxygen monitor is supplies with alarm relay outputs which may be used to signal a re-mote alarm, open a backup supply or the process stream, or close the process flow.Flow Rates (lpm) @ 100 psig, 68°FModel N2-300 N2-460 N2-600Atmospheric Dewpoint -58°F (-50°C) -58°F (-50°C) -58°F (-50°C)Commercially Sterile Yes Yes Yes Particles >0.01 micron None None NoneSuspended Liquids None None NoneMin/Max Operating Pressure 60 psig/145 psig 60 psig/145 psig 60 psig/145 psigMax Pressure Drop(at 95% N2, 125 psig) 15 psig 15 psig 15 psigOperating Temperature 70°F (21°C) 70°F (21°C) 70°F (21°C)Min/Max Inlet Air Temp. 50°F /104°F (10°F /40°F) 50°F /104°F (10°F /40°F) 50°F /104°F (10°F /40°F)Recommended Inlet Air Temp. 70°F (21°C) 70°F (21°C) 70°F (21°C)Electrical Requirements 90-250 VAC 50-60 Hz 90-250 VAC 50-60 Hz 90-250 VAC 50-60 HzDimensions 29”W x 31”D x 76”H 29”W x 42”D x 76”H 29”W x 53”D x 76”H (74cm x 51cm x 193cm) (74cm x 79cm x 193cm) (74cm x 107cm x 193cm)Shipping Weight 660 lbs. (300 kg) 870 lbs. (395 kg) 1,290 lbs. (586 kg)Model 99.5% 99% 98% 97% 96% 95%N2-300 200 311 538 736 935 1133N2-460 297 467 807 1104 1402 1699N2-600 396 623 1076 1473 1869 2266Products for TOC Analysis521-800-343-4048 www.labgasgenerators.comModel HPN2-1100Nitrogen Generators for TOC? Produces a continuous supply of high purity nitrogen gas from existing compressed air? Eliminates the need for costly, dangerous, inconvenient nitrogen cylinders in the laboratory? Ideal for all combustion, UV persulfate, and wet oxidation sampling techniques? Compact design frees up valuable laboratory floor space? Offers long term cost stability - uncontrollable vendor price increases, contract negotiations, long term commitments and tank rentals are no longer a concernThe Parker Balston® Models HPN2-1100 and UHPN2-1100 Nitrogen Generators can produce up to 1.1 lpm of ultra high purity nitrogen gas. These systems are completely engineered to transform standard compressed air into 99.9999% nitrogen, exceeding the specifi-cation of UHP cylinder gas.Nitrogen is produced by utilizing a combination of state-of-the art purification technologies and high efficiency filtration. The Model HPN2-2000 can produce up to 2 lpm of 99.99% pure nitrogen gas from standard compressed air. Pressure swing adsorption removes O2, CO2, and water vapor. A catalyst module is incorporated in the UHPN2-1100 to oxidize hydrocarbons from the inlet air supply. The generators also have high efficiency coalescing prefilters and a 0.01 micron (absolute) membrane filter incorporated into their design. The Parker Balston UHP Nitrogen Generators are engineered and packaged in a small cabinet to fit nearly any benchtop. The systems eliminate the need for costly, inconvenient high pressure nitrogen cylin-ders. The HPN2-1100 and UHPN2-1100 are ideal for TOC carrier gas and purge applications.Inlet Air Max Outlet Max Outlet Pressure Flow Pressure (psig) (cc/min.) (psig)Models HPN2-1100, UHPN2-1100 125 1100 85110 1000 75100 900 6590 800 6080 700 5070 600 4560 500 35Flow ChartProducts for TOC Analysis531-800-343-4048 www.labgasgenerators.comNitrogen Generators for TOCOrdering Information call 800-343-4048, 8 to 5 ESTPrincipal SpecificationsNotes:1 Model HPN2-1100 does not remove hydrocarbons and carbon monoxide2 Purity specification for Nitrogen does not include Argon concentration.3 Power Consumption is as follows: Model HPN2-1100 = 25 Watts, Model UHPN2-1100 = 700 Watts, Model HPN2-2000 = 25 Watts.4 Refer to voltage appendix for electrical and plug configurations for outside North America.Model HPN2-1100, UHPN2-1100 HPN2-2000Max Nitrogen flow rate See Flow Table 2 lpmNitrogen Purity 99.9999% 99.99%Max Nitrogen output pressure See Table 90 psigCO Concentration < 1 ppm NACO2 Concentration < 1 ppm < 1 ppmO2 Concentration < 1 ppm < 100 ppmH2O Concentration < 1 ppm < 1 ppmHydrocarbon concentration (1) < 0.1 ppm NAArgon Concentration (2) 0.9% 0.9%Min/Max Inlet Pressure 60 psig/125 psig 75 psig/120 psigRecommended Inlet Temperature 78°F (25°C) 78°F (25°C)Ambient Operating Temperature 60°F-100°F (16°C-38°C) 60°F-100°F (16°C-38°C)Max Air Consumption 42 lpm (1.5 scfm) 42 lpm (1.5 scfm)Inlet Connection 1/4” NPT (female) 1/4” NPT (female)Outlet Connection 1/8” NPT (female) 1/8” NPT (female)Electrical Requirements (3,4) 120 VAC/60 Hz 120 VAC/60 HzDimensions 12” w x 16” d x 35” h 12” w x 16” d x 35” h (31cm x 41cm x 89cm) (31cm x 41cm x 89cm)Shipping Weight 110 lbs. (50 kg) 110 lbs. (50 kg)Description Model NumbersHigh Purity Nitrogen Generator HPN2-1100, HPN2-2000Ultra High Purity Nitrogen Generator UHPN2-1100Purity Indicator/Scrubber 72092Optional Prefilter System 2002N-1B1-DXMaintenance Kit MK7692*, MK7694Installation Kit for all Models IK7694Preventive Maintenance Plan HPN2-1100-PM, UHPN2-1100-PM, HPN2-2000-PMExtended Support with 24 Month Warranty HPN2-1100-DN2, UHPN2-1100-DN2, HPN2-2000-DN2*For Model HPN2-1100
Most popular related searches