MDX Biotechnik International GmbH

Peristaltic Pumps- Brochure

medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 Innovative ? Handy ? Comfortable ? Exact microprocessor controlled peristaltic pumps multifunctional for all applications in laboratories of Analytics, Biotechnology, Medicine medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 Peristaltic Pumps TC / TU / TL / TB / TI / TV / HP Based on the peristaltic principle a perfect pump can transport the fluid sterile. Furthermore it is able to pump also highly viscose media without problems. Meredos peristaltic pumps succeed in both and distinguish themselves by: • Simple operation using 5 function keys • Easy change of tubes • Graphical LCD-display with two lines • Display of pump capacity in ml/min • Clockwise/anticlockwise rotation • Variable driving speed 1:100 controlled by microprocessor • Calibration, timer operation, cyclic operation, start and stop • High precision, linearity and reproducibility > 0.3% • Option of external triggering • Temperature and current limitation for max. reliability even on continuous operation • High quality motors with almost noiseless transmission • 6 and 8 roller heads with low pulsation • Usable as dosing pump • Pump heads can be disassembled easily and turned by 90° • Duplication of flow rate by parallel operation of two channels • Stackable case Operation: A touch pad with 5 function keys and a display with 2 lines ensure a very simple but comfortable operation of all meredos peristaltic pumps. The display shows all relevant data and information that leads through operation. The calibration function allows exact setting of the pump capacity by either selecting the % pumping speed or targeting the flow quantity directly. In timer mode pump capacity, time of intervals (pause) and the number of cycles are given values. In cyclic operation the pump capacity has to be set and operation initiated manually. In both modes the start may also be initiated using a foot switch. All data are saved until modification. Pump capacities: The pump capacities shown in the particular tables apply to a pump head with 3 rollers. With 6 rollers the pump capacity is reduced by about 30% and pulsation diminished. With 8 rollers the pump capacity is reduced by about 40% and pulsation is at lowest level. Options: • Timer and trigger • External control, analog 0 - 10 V • External control, analog (0) 4 - 20 mA • External control, digital RS 232 • 6-roller head • 8-roller head • 2-channel model • 3-channel model • 4-channel model • Stainless steel case • Foot switch medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 TC Flow rate per channel 6 - 2000 ml/min Pump head: Diameter 106 mm Number of rollers 3, 6, or 8 Number of channels 1-2 Technical data: Dimensions (WxHxD) 156 x 146 x 245 mm Weight with head 5,800 g Voltage 230 VAC Fuse T 1.2 A / 250 V Drive DC motor with gearbox Output 95 W Flow rate per channel: Number of rollers Tube Head Ø 106 ID x W [ml/min] 3 4.8 x 2.4 6-580 3 6.4 x 2.4 10-1020 3 8.0 x 2.4 15-1450 3 9.5 x 2.4 20-2000 Ordering information: Type Number of rollers Options TC 3 Timer and trigger, external triggering, analog 0 - 10 V, external triggering, analog (0) 4 - 20 mA, external triggering, digital RS 232, 6-roller head, 8-roller head, 2 channel model, housing of stainless steel, foot switch TU Flow rate per channel 0.4 - 980 ml/min Pump head: Diameter 84 or 62 mm Number of rollers 3, 6, or 8 Number of channels 1-8 Technical data: Dimensions (WxHxD) 156 x 146 x 203 mm Weight with head 4,700 g Voltage 230 VAC Fuse T 1.0 A / 250 V Drive DC motor with gear Output 48 W Flow rate per channel: Number of rollers Tube Head Ø 62 Head Ø 84 ID x W [ml/min] [ml/min] 3 1.6 x 1.6 0.4-40 0.6-55 3 3.2 x 1.6 1.5-150 2-210 3 4.8 x 1.6 3.5-340 5-480 3 6.4 x 1.6 - 8-820 3 8 x 1.6 - 10-980 Ordering information: Type Number of rollers Options TU 3 Timer and trigger, external triggering, analog 0 - 10 V, external triggering, analog (0) 4 - 20 mA, external triggering, digital RS 232, 6-roller head, 8-roller head, 2 channel model, 3 and 4 channel model, housing of stainless steel, foot switch medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 TL Flow rate per channel 0.001 - 240 ml/min Pump head: Diameter 62 mm Number of rollers 3, 6, or 8 Number of channels 1-4 Technical data: Dimensions (WxHxD) 134 x 131 x 190 mm Weight with head 1,800 g Voltage 230 VAC Fuse T 0.2 A / 250 V Drive DC motor with gear Output 10 W Flow rate per channel: Number of rollers Tube Driving speed 150 rpm 10 rpm ID x W ml/min µ/min 3 0.13 x 0.8 0.01-0.090 0.1-7 3 0.5 x 0.8 0.014-1.35 1-90 3 1 x 1 0.15-15 10-1,000 3 2 x 1 0.5-50 33-3,300 3 3 x 1 1.2-120 80-8,000 3 4 x 1 1.7-170 110-11,000 3 1.6 x 1.6 0.3 30 20 - 2000 3 3.2 x 1.6 1.2 – 170 80 - 8000 3 4.8 x 1.6 2.4-240 160-16,000 Ordering information: Type Number of rollers Options TL/150 TL/10 3 Timer and trigger, external triggering, analog 0 - 10 V, external triggering, analog (0) 4 - 20 mA, external triggering, digital RS 232, 6-roller head, 8-roller head, 2 channel model, 3 and 4 channel model, housing of stainless steel, foot switch TB / TBS / TBE Flow rate per channel 1,5 - 240 / TBS 6 - 980 / TBE 1,5 – 2000 ml/min Simple operation via two control knobs Variable driving speed TB / TBS 1:10 / TBE 1:20 Pump head: Diameter 62 mm / 84 mm / 106 mm Number of rollers 3, 6, or 8 Number of channels 1-2 Technical data: Dimensions (WxHxD) 134 x 131 x 190 mm Weight with head TB / TBS 1,700 / TBE 2400 g Voltage 230 VAC Fuse TB / TBS T 0.2 A / TBE 0,63 A Drive DC motor Output 10 W / 15 W / 35 W Flow rate per channel: TB / TBE TBS / TBE TBE Number of rollers Tube Head Ø 62 Head Ø 84 Head Ø 106 ID x W [ml/min] [ml/min] 3 1,6 x 1,6 1,5 - 30 6 - 55 3 3,2 x 1,6 6 - 120 11 - 210 3 4,8 x 1,6 12 - 240 25 -480 6 - 580 3 6,4 x 1,6 - 41 - 820 10 - 1020 3 8 x 1,6 - 50 - 980 15 – 1450 3 9,5 x 2,4 - - 20 - 2000 Ordering information: Type Number of rollers Options TB 3 6 and 8-roller head, 2 channel model, housing of stainless steel TBS 3 6 and 8-roller head, housing of stainless steel TBE 3 6 and 8-roller head, 2 channel model, housing of stainless steel medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 TV/TVS Flow rate per channel 0.4 - 130 / TVS 55 - 980 ml/min Available with 3 fixed driving speeds Standard: 50 rpm Pump head: Diameter 62 mm / 84 mm Number of rollers 3, 6, or 8 Number of channels 1-4 (2) Technical data: Dimensions (WxHxD) 134 x 131 x 190 mm Weight with head 1,800 g Voltage 230 VAC Fuse T 0.2 A / 250 V Drive AC motor with gear/ DC motor with gear Output 5 W / 15 W Flow rate per channel: Type TV/20 TV/50 TV/100 TVS Head Ø 62 Ø 62 Ø 62 Ø 84 Speed rpm 20 50 100 200 No. of channels 1-4 1-2 1-2 1-2 No. of rollers Tube ID x W ml/min 3 0.5 x 1 0.4 1.0 2 - 3 1 x 1 1.5 3.7 7.5 - 3 2 x 1 6 15 30 - 3 3 x 1 13 33 65 - 3 4 x 1 20 50 100 - 3 1,6 x 1,6 4 10 20 55 3 3,2 x 1,6 15 37 73 210 3 4.8 x 1.6 26 65 130 480 3 6,4 x 1,6 - - - 820 3 8,0 x 1,6 - - - 980 Ordering information: Type Number of rollers Options TV/20 3 6-roller head, 8-roller head, 2, 3, and 4 channel model, housing of stainless steel, foot switch TV/50 TV/100 3 2 channel, the rest like above TVS 3 Only 1 channel, TI Flow rate per channel 0.4 - 130 ml/min Timer pump, cyclic operation, number of doses and intervals may be preselected from 0.1 to 999 s on the 2 lines of the LCD display, dose-pulse triggering at the device or extern by floating contact. Available with 3 fixed driving speeds Standard: 50 rpm Pump head: Diameter 62 mm Number of rollers 3, 6, or 8 Number of channels 1-4 (2) Technical data: Dimensions (WxHxD) 134 x 131 x 190 mm Weight with head 1,800 g Voltage 230 VAC Fuse T 0.2 A / 250 V Drive AC motor with gear Output 5 W Flow rate per channel: Speed rpm 20 50 100 No. of channels 1-4 1-2 1-2 Tube ID x W ml/min 0.5 x 1 0.4 1.0 2 1 x 1 1.5 3.7 7.5 2 x 1 6 15 30 3 x 1 13 33 65 4 x 1 20 50 100 4.8 x 1.6 26 65 130 Ordering information: Type Number of rollers Options TI62/20 3 6-roller head, 8-roller head, 2, 3, and 4 channel model, housing of stainless steel, foot switch TI62/50 TI62/100 3 See above but without 3 and 4 channel models medorex e.K. • Industriestr. 2 Tor 1 D-37176 Noerten-Hardenberg Phone +49 (0)5503-8086-62 • Fax -32 Owner Dr. S. Mohazzeb email: info@medorex.com http://www.medorex.com HRA 130920 AG Göttingen UID DE 239250100 IBAN: DE70 2625 0001 0000 0118 25 BIC: NOLADE21NOM Kreis-Sparkasse Northeim Kto-Nr. 11825 • BLZ 262 500 01 HP Flow rate per channel 0,05 µµµµl - 27 ml/min Pump head: Diameter 42 mm Number of rollers 6 Number of channels 1 Technical data: Dimensions (WxHxD) 73 x 56 x 120 mm Weight with head 550 g Voltage 12 VAC/DC External power supply 110/220 VAC Drive DC motor with gear Output 6 W Flow rate per channel: Number Tube Driving speed of rollers 90 rpm 10 rpm ID x W ml/min µl/min 6 0,13 x 0,8 0,005-0,045 0,05-5 6 0,5 x 0,8 0,007-0,65 0,8 - 75 6 1 x 0,8 0,025 - 2,5 4 - 420 6 1,5 x 0,8 0,5 - 5,5 8 - 820 6 2 x 0,8 0,1 - 10 13 - 1250 6 2,5x 0,8 0,15 - 17 17 - 1700 3 2,8 x 0,8 0,3 - 27 33 - 3300 Ordering information: Type Number of rollers Options HP/90 HP/10 6 Timer and trigger, external triggering, analog 0 - 10 V, external triggering, analog (0) 4 - 20 mA, external triggering, digital RS 232, foot switch Insertion of tubes 1. Open swivel lever 2. Remove tube cassette 3. Insert appropriate tube 4. Pull tube tight and Insert the tube cassette 5. Close swivel lever until it locks Commercial tubes without stopper can be used
Most popular related searches