KERNEL Sistemi s.r.l
- Home
- Companies & Suppliers
- KERNEL Sistemi s.r.l
- Downloads
- PLC For Industrial Automation And PLC ...
PLC For Industrial Automation And PLC For Building Automation DMX 20/S
GTP 20 Data SheetDMX 20Operator panel with integrated PLC• - Fixing system on din rail - High speed (2msec. standard cycle time) - Contact programmation with Ladder language - Function for Recipe management , P.I.D. Regulator , Print etc ... - Two Load Cell analog inputs (16 bits)ELECTRIC CHARACTERISTICSPower supply voltage Min 20Vcc ; Max 26 VccMin 15 Vac ; Max 21 VacCurrent Consumption Under 50mA without loadsMicroprocessor Hitachi H8S/2145B @ 20MHzProgram Memory 64 KBPages Memory 64 KBE²PROM 64 KBCycle Time Programmable (minimum 1 msec.)Digital Inputs 8 digital inputs PNP at 24 Volts of which 4 fast input (2KHz for encoder reading) with programmable anti-noise filter (value 0..255)Analog Inputs 2 analog inputs for load cell 2/3 mV/V with 16 bits resolution [0..65535] .Digital Outputs 8 PNP relay 24V or 220V Analog Outputs 2 analog outputs 0...10V with 8 bits resolution [0...255] KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 1Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it GTP 20 Data SheetELECTRIC CHARACTERISTICSI/O Connections KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 2Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it GTP 20 Data SheetELECTRIC CHARACTERISTICSPlugged RAM 79 words any 100 msec automatically copy into plugged RAM (for a term of 1 year)RTC Extern real time clock with plugged calendar and clock with rechargable battery . (for a term of 1 year)Serial Lines2 serial lines (COM 0 , COM 1 ) .COM 0 : It could be used in RS232 , RS485 or RS422 with many different standard comunication protocols for connect other devices (I/O expansions , termoregulators , inverters or network connection) . COM 1 : It could be used in RS232 or RS 485 mode and it'is use like COM0 , besides for upload applications or operative system . KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 3Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it GTP 20 Data SheetELECTRIC CHARACTERISTICS KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 4Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it GTP 20 Data SheetMECHANICS CHARACTERISTICSHumidity Range from 10 to 90% (non-condensingTemperature Range from -10 °C to +70 °COperating Atmosphere Without corrosive gasNoise Immunity According to rules in force Fixing System On din railWeight 450 gKeyboard 4 dedicated buttons .Display Alphanumeric display 16 characters on 2 rows , backlight LED.Size Front view 160x90 mm , Depth 59 mm KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 5Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it GTP 20 Data SheetSOFTWARE CHARACTERISTICSProgramming Languages AWL / LadderTimers 64 timers with 16 bits and resolution 1/100 sec . 32 configurable timers one by one like excitation delay or disexcitation delay and 32 only excitation timers . 8 timers free running with 1 msec resolution enabled one by one with system flag . Counters 32 counters with 16 bits configurable one by one like incremental or decremental .Data Memory 2048Developed Functions • Week Programming• Recipe Management• Forwarding/Reception SMS Messages• Encoders Management• P.I.D. Temperature's RegulatorMemory area check in real time mode on data table ( Debug )Ladder's subroutines Import/ExportContact and variable check in real time mode on ladder ( Debug Online ) KERNEL sistemi s.r.l. - Via Vignolese, 1138 – 41100 Modena (MO) – Italy 6Tel: 059 469978 – Fax: 059 468874 - Email: info@kernel.modena.it - www.kernel.modena.it
Most popular related searches