Drexelbrook - AMETEK, Inc
- Home
- Companies & Suppliers
- Drexelbrook - AMETEK, Inc
- Downloads
- Plugged Chute Detector Datasheet
Plugged Chute Detector Datasheet
DREXELBROOKDREXELBROOK®A Leader In Level Measurement SolutionsThePoint™ RFSeriesEliminate Costly Plugged Chutes with Drexelbrook SensorsDowntime is expensive and so is the clean up of process spills. Reliable detection of plugged chutes will keep your plant running smoothly and virtually eliminate spills that occur because of plugged conditions.Drexelbrook’s Flush-Mounted Sensors reliably detect presence or absence of material flowing through chutes. If process material stops flowing due to a plugged condition, the system will alarm, allowing further action to occur (alerting an operator, shutting down a conveyor belt, etc.). This permits the operator to prevent a problem before it happens.Rugged sensor design makes these systems ideal for coal (pulverizer and transfer chutes), wood chips, ores, powders, etc. Since they are flush mounted through a chute wall, nothing protrudes into the chute to interfere with or to obstruct material flow.Dust coating and/or wall build up will not affect the measurement.Drexelbrooks Cote-Shield circuitry “Sees” through any coating condition and eliminates false plugged chute signals.Curved and flat sensors are available.Chutes vary in size and shape. We have a sensor design to fit your chute.Point Level Switch for Plugged Chute DetectionIntelligent Electronics Save Time and Money• Automatically recognizes and ignores coatings to prevent false alarms.• Universal power supply automatically detects & adjusts to input power source• Standard & High Sensitivity Electronics, Field SelectableApplication• Detects the presence of plugged material in chutesEconomical Without Sacrifice• Retains superior performance.• Less maintenance than other technologies; no moving parts to hang up or wear out.Output • DPDT relay dry contacts at 5A, 120VAC.Remote Electronics• Unlike many technologies, electronics can be remote mounted to a convenient or safe locationTechnology: RF Admittance.Calibration: None (for most applications).Modes Of Operation:High and Low Level.Repeatability:2 mm (0.08 inch) conductive liquids.Response Time:Less than one second.Ambient Electronic Temperature:-40 to 70°C (-40 to 158°F) FM, CSAStorage Temperature:-40 to 85°C (-40 to 185°F).Indicators:LEDs: Green Power, Red Relay 1.Time Delay:0-60 seconds, forward or reverse-acting.Supply Voltage:19-250 VAC18-200 VDCAuto-detecting without jumpers.Power Consumption:2 watts maximum.Relay Contacts: DPDT dry contacts at 5A, 120Vac.Maximum Contact Load: 5A/30 VDC5A/250 VAC Maximum Switching Capacity: 2000 VA/150 Watt.Minimum Contact Load (DC):100 mA/12 VDC0 -200 mA / 12 VDC (Optional)Housing:Powder-Coated aluminum with two cable entries.Cable Entry:M20 x 1.5 ¾-inch NPT Ingress Protection:IP66 NEMA 4XApprovals:Remote SensorsExplosion-proof for Class I, Division 1, Groups A, B, C, and D; Dust-Ignition proof for Class II, III, Division 1, Groups E, F, and G; Non-incendiary for Class I, Division 2, Groups A, B, C, & D; Suitable for Class II, III, Groups F & G hazardous outdoor Type 4X, IP66 (classified) locations with Intrinsically Safe connections to Class I, II, III, Division 1, Groups A, B, C, D, E, F, and G hazardous (classified) locations in accordance with Control Drawing 420-0004-181-CD.Integral:[Same, but Group A does not apply.] Remote SensorsClass I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; Type 4, 4X, IP66; T5 for Ta = 70o C Class I, Division 2, Groups A, B, C, D; Class II, Division 2, Groups F, G; Class III; Type 4, 4X, IP66; T5 for Ta = 70o C II 1/2 GD EEx d[ia] IIC T2..T5, Ta = -30°C to +70°CThe Point™Specifications19 to 253 Vac19 to 55 VdcAuto-Detecting Without Jumpers4.5"(114mm)6.5"(165mm)4.75"(121mm)DimensionsWiringSAA (For Remote Electronics)Electronics Ex d[ia] IIC T5 DIP A21 Ta = -100°CSensing Element Ex ia IIC T6The Point™Model NumberingSensing ElementPlugged Chute Detection (1) Available with remote electronics only (2) Use P00X mounting optionApplication Sensing Element Pressure/Temperature Wetted Parts50 Flush Mount Sensor 700-0207-001 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Polyurethane heavy duty51 Flush Mount Sensor 700-0207-002 0.1 bar @ 149°C (1 PSI @ 300°F) 304 SS and TFE 305mm2 (12 inches2) higher temperature52 Flush Mount Sensor 700-0207-003 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 305mm2 (12 inches2) Neoprene with curved radius 153, 229, 305 mm (6, 9, or 12 inches)53 Flush Mount Sensor 700-0207-004 0.1 bar @ 82°C (1 PSI @ 180°F) 410 SS and 305mm2 (12 inches2) UHMW extra heavy duty Polyethylene55 Flush Mount Sensor 700-0207-006 0.1 bar @ 82°C (1 PSI @ 180°F) 304 SS and 203mm2 (8 inches2) Polyurethane heavy dutyZZ Sensing Element Not ListedHousing0 No Approvals, NEMA 4X/IP66, M20 x 1.5 conduit entries1 No Approvals, NEMA 4X/IP66 ¾" NPT conduit entries2 CENELEC/ATEX 3 FM Approved4 CSA Approved TechnologyP RF AdmittanceInputL Universal Power Supply 21-100 VDC, 85-250 VAC, 0-400 HzMeasurement TypeM Manual Set Point, Point LevelG Manual Set Point, Point Level, High SensitivityP00X IL/CSL factory set for Plugged ChuteMounting TypeP00XOutput1 One DPDT Relay, dry contacts, 5A, 120VAC (Min 100 mA / 12 VDC) 2 One DPDT Relay, gold plated contacts (Max 200 mA / 12 VDC)Electronics1 Remote, no cable2 Rmt. w/ 3 m (10 ft.) G.P. cable3 Rmt. w/ 7.6 m (25 ft.) G.P. cable4 Rmt. w/ 10.6 m (35 ft.) G.P. cable5 Rmt. w/ 15.2 m (50 ft.) G.P. cable6 Rmt. w/ 23 m (75 ft.) G.P. cable7 Rmt. w/ (25 ft.) Tri-Ax Cable8 Rmt. w/ (50 ft.) Tri-Ax Cable9 Rmt. w/ (75 ft.) Tri-Ax CableA Rmt. w/ (10 ft.) Hi-Temp. CableB Rmt. w/ (25 ft.) 1st 10ft Hi-Temp. Cbl.C Rmt. w/ (35 ft.) 1st 10ft Hi-Temp. Cbl.D Rmt. w/ (50 ft.) 1st 10ft Hi-Temp. Cbl.E Rmt. w/ (75 ft.) 1st 10ft Hi-Temp. Cbl.F Rmt. w/ (5 ft.) G.P. CableG Rmt. w/ (5 ft.) Tri-Ax CableH Rmt. w/ (10 ft.) Tri-Ax CableJ Rmt. w/ (35 ft.) Tri-Ax CableK Rmt. w/ (5 ft.) Hi-Temp. CableAMETEK Nihon Drexelbrook AMETEK Singapore Pte. Ltd. AMETEK Precision Instruments Europe2 Chome • 12-7 Minami Gyotoku 10 Ang Mo Kio Street 65 Rudolf-Diesel-Strasse 16 Ichikawa City • Chiba 27201 Japan #05-12 Techpoint • 569059 Singapore D-40670 Meerbusch Germany Phone: 81-473-56-6513 Phone: 65-6484-2388 Phone: 49-2159-9136-0 Fax: 81-473-56-6535 Fax: 65-6481-6588 Fax: 49-2159-9136-39E-mail: nd@nihon-drexelbrook.co.jp E-mail: aspl@ametek.com.sg Web: www.ametek.de U.S.A. Sales: 800-553-9092 • 24-Hour Service: 800-527-6297 • International Support: 215-674-1234 • Fax: 215-674-2731DREXELBROOK205 Keith Valley RoadHorsham PA 19044 U.S.A.E-mail-drexelbrook.info@ametek.comWeb-www.drexelbrook.com ©2006, by AMETEK, Inc. All rights reserved. • Printed in the U.S.A. • PML1-PC-A • EDO#3-06-243 • Issue# 1AMETEK Nihon Drexelbrook AMETEK Singapore Pte. Ltd. AMETEK Precision Instruments Europe2 Chome • 12-7 Minami Gyotoku 10 Ang Mo Kio Street 65 Rudolf-Diesel-Strasse 16 Ichikawa City • Chiba 27201 Japan #05-12 Techpoint • 569059 Singapore D-40670 Meerbusch Germany Phone: 81-473-56-6513 Phone: 65-6484-2388 Phone: 49-2159-9136-0 Fax: 81-473-56-6535 Fax: 65-6481-6588 Fax: 49-2159-9136-39E-mail: nd@nihon-drexelbrook.co.jp E-mail: aspl@ametek.com.sg Web: www.ametek.deU.S.A. Sales: 800-553-9092 • 24-Hour Service: 800-527-6297 • International Support: 215-674-1234 • Fax: 215-674-2731DREXELBROOK205 Keith Valley RoadHorsham PA 19044 U.S.A.E-mail - drexelbrook.info@ametek.comWeb - www.drexelbrook.com ©2006, by AMETEK, Inc. All rights reserved. • Printed in the U.S.A. Other Great Solutions By: DREXELBROOK ®Two-Wire Point Level SwitchIntelligent ElectronicsIntelliPoint RF™ SeriesOne of the Drexelbrook RF Point Level Switches You Won't Have to Calibrate The onlyinstall theand applycapacitancesetpointpushbuttons,detectsany adjustments. The IntelliPointmonitorsdielectrictrip pointsystemsthe processIntelliPointit is ideala wide varietySelf-Test Feature AutomaticThe Point™The Point™ Two-Wire RF Series Point Level SwitchTF-100™ SeriesVibrating Tuning Fork #LEAR?,INE©????
?????3ERIES)N
,INE?&LUID?$ETECTOR
Most popular related searches