Acid VaporsBreakthrough IndicatorInlineAcids BTI Inline(PN: 602)SPECIFICATIONSAcid Vapors BTI Inline SpecificationsChemteq, Inc., 600 West 24th Street, Suite B, Norfolk, Virginia 23517, Tel 757-622-2223, sales@chemteq.net©2009 Chemteq, Inc. MP-6028100-040414 A1. ApplicationThe Acid Vapors BTI inline (PN: 602) is qualitative (yes/no) colorimetric indicator for real-timeindication of acid vapors.2. Specificationsa. Weight: 28g (1.0oz)b. Dimensions: 89.9mm (3.5in), diameter 24.5mm (1.0in)c. Inlet & outlet dimensions: ¾" MNPTd. Operating temperature: -20oC to 55oC (-4oF to 131oF)e. Operating humidity: 5% RH to 90%RHf. Minimum detectable limit: 4ppm•min at 30 cm/sec face velocityg. Color change: Yellow to orange to dark redh. Storage temperature: 4oC to 25oC, (39oF to 77oF)i. Shelf life: 14 months at 4oC to 25oC, (39oF to 77oF)j. Service life: 1 yearCross interferences: Basic vapors in high concentrations impair the performance of the acidsbreakthrough indicator. No other interferences are known.3. Instructionsa. Ensure that packaging pouch is intact.b. Open packaging pouch by tearing off the top part from one of side notches.c. Remove the BTI Inline from the packaging pouch.d. Remove the protective red plugs to activate the breakthrough indicator.e. Formation of orange or red color indicates the presence of acid vapors.YOU CAN REUSE THE EXHAUSTED ACIDS BTI INLINE BY REPLACING THE CONSUMEDACIDS INDICATOR ASSEMBLY WITH A FRESH INDICATOR ASSEMBLY (PN: 602-1600).PLEASE CONTACT US FOR DETAILS.www.chemteq.netOverExposedReplaceFilter