China Sciences MapUniverse Technology Co.,Ltd
Product List
Mapuni Environmental Monitoring Solutions Catalogue Version 1.0 China Sciences MapUniverse Technology Co., Ltd. Designed by International Business Department Professional Environmental Monitoring Solutions 2 Index Chapter 1: Water Quality Monitoring A. Online Monitoring Series 1. WD2100 CODCr (Chemical Oxygen Demand) On-line Monitoring Instrument 2. WD2200-NH3-N Online Automatic Analyzer On-line Automatic Monitoring Instrument B. Heavy Metal Monitoring C. ZZW-Site Multi-parameter Water Quality Tester (Fast Detection) Chapter 2 :Gas Quality Monitoring Chapter 3 :Noise Quality Monitoring Chapter 4: RTU Chapter 5 :Emergency Monitoring Chapter 6 :Unmanned Aerial Vehicle Chapter 7: Radiation Monitoring Professional Environmental Monitoring Solutions 3 Chapter 1 Water Quality Monitoring A. Online Monitoring Series 1. WD2100 CODCr (Chemical Oxygen Demand) On-line Monitoring Instrument Introduction WD2100 COD Cr (Chemical Oxygen Demand) ON-LINE MONITORING INSTRUMENT has unique patent technology based on the air pressure transmission optimization, which realized on-mechanical sample delivery, made mutual independent among circuit control, sample handling unit and inspection unit, reduced mutual interference, improved its running performance. Closed loop feedback dual wavelength mixed detection technology resolved the problems of zero drift from photoelectrical detection equipment at mainland and abroad at present, improving the accuracy of COD online inspection analyzer, easy to use, simple operation. High precision measurement of the quality of pump patented technology, effectively solve the peristaltic pump is the prevalence of the rolling wheel assembly and the inner wall of the pump body are adjustable gap of technical difficulties, the realization of a small dose of the high precision quantitative mixed reagent; and reduced reagent usage; improve the service life; ensuring the measurement accuracy. Sample pretreatment patent technology made samples in the function of homogenization, filtering, removing some suspended matters, loss from COD filtering and preserving over-proof samples. Applying advanced hybrid mode operation, realizing high-accuracy, high stability and on-time measurements on CODCr value. Features ? Calibration: range and zero point (calibration and blank calibration) and calibrated by manual and automatic operation. Professional Environmental Monitoring Solutions 4 ? Auto-cleaning: dealing with equipment, sampling pipe, instrument pipe, valves and other parts before twice auto-cleaning at the beginning and ending of measuring. ? Defensive Function: self-protection when it in the situation of power outage, water-break and auto-restored function. ? Auto-alarm: Auto-alarming on the condition of system fault, power outage, short of sample and distilled water, other abnormal inspected data, alarm signal data above can be transferred to remote control network. ? Remote Control: both-way communication and revert control function between PC or data sampler and equipments, controlling analyzer by upper computer, remote-upgrading data sampler or analyzer by internet. ? Automatic and Manual Measurement: measuring by auto-online, manual-offline and auto-offline. ? Display: LCD operational interface (5.7 Inch), displaying running status. ? Storage: stored detection data above 2000 groups, supporting RS-232, RS-485 communication terminal, 4~20mA output. ? Communication Protocol: formulated based on requirements. ? Data Output: simulation(4~20, 0~20mA, 0~5v) (adapting),digit (RS232 orRS485). Specifications Item Specifications Analytical Procedure water quality-chemical oxygen demand admeasurements- potassium dichromate method Installation Landing Protection IP54; Interior installation Display LCD 320×240 Insulation Resistance >100M? Size 600×500×1300mm(length × width × height) Weight About 100Kg Sample requirements Temperature 5~45? Clarity Transparent, if suspended matter exists, conduct homogenizing treatment ( pretreatment unit attached) Handling pressure 1~5psi Parameters Measuring range 30~5000mg/L Inspection period <30min Zero drift ±5mg/L Span drift ±10% Repeatability =100mg/L repeatable error±5% <100mg/L repeatable error±5mg/L MTBF =1440h Cl- Shield Maximum 5000mg/L Reagent Replacement >15days Data Storage >1year Professional Environmental Monitoring Solutions 5 Output Analog quantity: 4-20mA Communication interface; RS232 Switching value output: 4 Communication RS232 Environmental requirements Temperature 5~30? Humidity <80% RH Storage Temp. 0~40? Power Voltage AC220V±10%,50Hz±5% Power Meter <250W Applications Widely applied to COD concentration monitoring on floss hole of pollution source, municipal wastewater, industrial sewage, commercial running water, rivers, lakes, reservoirs and tap Water pipe-network, served for Environmental Administration, Water Corporation and other enterprises in chemical industry, metallurgy, paper, pharmaceutical, food industries, sewage treatment plants, surface water and other fields. 2. WD2200-NH3-N Online Automatic Analyzer On-line Automatic Monitoring Instrument Introduction WD2200 -NH3-N (ammonia nitrogen) online automatic analyzer achieved ammonia nitrogen online analysis by adopting advanced flow injection analysis, which can measures ammonia nitrogen concentration of different levels, suitable for lab or on-site online rapid analysis the ammonia nitrogen concentration of main water body, tap water, waste water emission, sewage of different concentration and all kinds of solutions. Features ? Heating, blowing, eluting and circulation loop absorption, fully absorbing ammonia produced in the processing. ? Multichannel rotary valve, long-life injection pump and high-accuracy liquid sampling institution of modular design by the methods of optical measurement, ensuring the accuracy and repeatability of the data. ? Double ray compensation measuring technique and the lighting source automatic adjustment technology, screening interference from outside physical changes (temperature drift, power supply voltage drift and so on). ? Peristaltic pump be replaced by injection pump by independent R&D, improved sample Professional Environmental Monitoring Solutions 6 handling and accuracy of measurement. Specifications Item Specifications Measuring Range (0.05~1000)mg/L Repeatability =3% Zero Drift ±0.5mg/L Span Drift ±4%FS/24h Error of Indication proportional error within ±10% Insulation Resistance 20MO above Voltage Resistance no voltaic arc and breakdown Ambient Temperature 5?~35?,temperature variation within 5? Relative Humidity =85% Supply Voltage (220±22) V Supply Frequency (50±1) Hz Applications Widely applied to ammonia nitrogen concentration monitoring on floss hole of pollution source, municipal wastewater, industrial sewage, commercial running water, rivers, lakes, reservoirs and tap Water pipe-network, served for Environmental Administration, Water Corporation and other enterprises. 3. WX1000 WATER QUALITY AUTOMATION SAMPLER Introduction WX1000 sampler controlled by controller, getting the water sample into instrument by measuring peristaltic pump, set up the constant temperature at 4?, so that the water sample of auto-collection, auto-allocation and constant temp. storage will be accomplished. WX1000 sampler can get samples in various ways based on circling, flow, impulse and appointed time by monolithic control, and also can achieve sampling, revising parameters, obtaining sample record through remote control. WX1000 sampler has its protection function of password and power-off, which is an intelligent automatic sampler for commercial water quality. Professional Environmental Monitoring Solutions 7 Features ? Stainless steel shell and outdoor plastic spraying, intensity, corrosion prevention. ? Sample by grouping bottles: 1~24 bottles(samples by grouping bottles). ? Constant temp. storage: sample can be stored properly under the control of temperature control system. ? Various ways of activation: cycle, timing, accumulate, pulse and instant flow, accumulating flow circle, pulse circle and remote running. ? Sampling record: recording sampling time, quantity and way of activation. ? Communication: RS485 connector, remote conducting sampling, remote revised data and remote picking up sampling record. ? Power-off protection: automatic data storing and no data loss during power failure. ? Off board pump control: when sampling distance is larger than that of internal sampling pump, off board pump will be used for controlling. ? Mix: single sample of many bottles, multiple samples of each bottle mix-mining. Specifications Item Specifications Single sampling 500ml Sampling interval 2~9999mins, easily set by customers Temp control 4?±2? The absorbing height of internal sampling pump 6 meters Sampling accuracy ±5ML Operating voltage AC220V±10%,50HZ Operating temperature 0?~40? Operating humidity less than 85% Applications Collecting and storing water sample by advanced auto-control technology and accurate measuring methods, which used for the online inspection system on pollution source, automatic monitor station on water quality and commercial analysis system. 4. E6811 Total Organic Carbon Analyzer Introduction Low-temperature combustion catalytic oxidation-NDIR method for the determination of water samples total organic carbon(TOC) content of the line automatic monitoring equipment for monitoring the total organic matter in water, according to a certain conversion factor into Professional Environmental Monitoring Solutions 8 COD,BOD values are widely applied in water environmental quality monitoring, pollution emission monitoring and industrial process control and other application field. Features ? 660? low temperature airtight combustion, non-dispersive infrared absorption detection CO2 concentration. ? Widely application for seawater, industrial sewage, surface water of high chloride ion. ? Little consumption of chemical reagent, fast and simple measuring. ? Configuration touch screen, easy to maintain and operation, remote setup and diagnosis. ? Over 10,000 data storage capacity, without any loss when power breakdown. ? Auto-alarm when malfunction or exceptional value. ? Self-protection and auto-restoration when in the situation of power outage, water-break and auto-restored function. ? Manual operation, auto-correction, remote correction and auto-cleaning. ? The veracity, safety and completeness of data, system stability will be guaranteed by the controller at technical grade. Specifications Item Specifications Monitoring object Total Organic Carbon(TOC) Measuring range 0~2500mg/l(TOC)/ 0~1000mg/l(COD) Repeatability 3% Zero drift ±3% F•S. Range drift ±3% F•S Response time 5min Error of indication ±5% F•S. Parameter display TOC or COD Correction Zero auto-correction Display LCD, touch screen, digital display (mg/l) Analog output 4~20mA Communication interface RS485/RS232 Insulation Resistance >20MO Voltage resistance No electric or breakdown Mean Time Between =1440h/times Professional Environmental Monitoring Solutions 9 Failures(MTBF) Power supply (220±22) VAC , (50±0.5)Hz Overall dimension (W×H×D)500mm×800mm×400mm Weight 40kg Applications Deionization pure water, purified water in pharmaceutical industry, water for injection and pharmacy and biochemistry. Professional Environmental Monitoring Solutions 10 B. Heavy Metal Monitoring 1. LumiFox 2000 Hand-held Blinking Bacteria Toxic Monitor Introduction LumiFox 2000 hand-held blinking bacteria toxic detector is new product launched by Mapuni, working principle is to do toxicity testing water quality through integrated luminescence intensity of luminous bacteria to determine the inhibition rate of the strength of the toxicity of water samples. ???: Reagent Storage ??? LCD: High definition LCD ???????:Streamline waterproof design ? Small and exquisite, less than 200g; ? Table model design for better on-site monitoring; ? Good quality of HIV strains, stable performance; ? Superior technical service; Features ? Fast, detecting within 5min; ? Accuracy (error less than 2%); ? Composite toxic level in the water sample can be detected by one time monitoring; ? Monitoring range: heavy metal ion, organic phosphorus, organic and inorganic toxic substances; ? Easy to use, no technicians needed; Specifications Item Specifications Type of reagent open Monitoring time 5 minutes at fastest Professional Environmental Monitoring Solutions 11 Weight ? <200g(excluded battery) Data storage capacity ? 1000 groups Accessories and Consumable Items ? Standard configuration kit ? Portable cases ? Test-tube stand ? Testing tube ? Pipette ? Operating instruction manual Successful Cases ? The 16th Asian Games in Guangzhou ? Games for university students in Shenzhen ? Laboratory of colleges and universities ? Environmental monitoring station in China, India, Thailand and so on. ? Running-water companies in China, India, Thailand and so on. 2. NanoTek2000 Portable Heavy Metal Tester Introduction NanoTek2000 adopts one proprietary technology in the electrochemical analysis (ASV), unique design of the reaction chamber, which greatly improved the monitoring accuracy and sensitivity, while the operation of the instrument is so easy. ? Smallest and exquisite heavy metal tester ? Sensitivity, reached ppb ? Fast measuring, single test less than 5 minutes ? Intelligent guide ? Table model for on-site monitoring ? Superior technical support Professional Environmental Monitoring Solutions 12 Features ? Built-in over 20 programmable analysis menu, users are easy to develop more parameters by themselves. ? Easy to monitor mercury, arsenic, lead, zinc, cadmium, copper, and chromium, nickel, manganese, thallium, ferrum and other heavy metal ion monitoring can be expandable. ? On-site operating platform for field monitoring. ? The accuracy of monitoring is better than ppb, fastest monitoring time is 25 sec. ? Authorized professional and in time feedback on customer demand. ? Waterproof for outdoors. ? Electrode performance stable, easy to maintain. Specifications Item Specifications Principle (ASV) Monitoring ions Mercury,arsenic,lead,zinc,cadmium,copper,chromium,nickel,manganese,thallium,ferrum etc. Range 0.5ppb~500ppm Resolution ratio 0.25ppb Time 25 second Accuracy ±3%(100ppb) Power supply Built-in Battery Interface RS232,USB Size 180mm*90mm*35mm Weight 0.5Kg Professional Environmental Monitoring Solutions 13 Standard HZ-HJ-SZ-0116 GB 17378.4-2007 EPA Method 1001(Pb) EPA Method 7063 (As) EPA Method 7472 (Hg) ASTM Method D3557-95 ISO 6636-1 Zn in fruit and vegetables ISO 8391-1 Pb and Cd in ceramics AOAC Method 982.23: AOAC Method 974.13: NIOSH Method 7701 Applications For the determination on the content of heavy metals in drinking water, surface water, groundwater, beverage, environmental water, sea water, industrial waste and other body of water, the method of which is also widely used to detect soil, food, heavy metals in the solid material. 2.NanoTek9000 Multi-parameter on-line Heavy Metal Analyzer Introduction NanoTek 9000 uses the module design to be the world’s largest online heavy metal monitoring parameters analysis system. Adopt popular anodic stripping voltammetry (ASV). NanoTek 9000 is easy to monitor the values of multiple-line heavy metals, low monitoring limit with high accuracy, easy to use, low cost, which can be applied to surface water, tap water, seawater, industrial wastewater and other real-time monitoring. ASV is replaced of traditional medicine because of its high sensitivity and low cost, which widely applied for biological and environmental analysis, atomic absorption spectrometry. Methods authorized internationally as follows: ? US EPA Method 7063 (As) and 7472 (Hg) [SW846] ? DIN 38 406, part 16, Zn, Cd, Pb, Cu, Tl, Ni, Co in water samples ? ISO 6636-1 Zn in fruit and vegetables ? ISO 8391-1 Pb and Cd in ceramics Professional Environmental Monitoring Solutions 14 Features ? An analyzer for on line monitoring multi heavy metals, can be reached ng/L; ? Creative module design, analysis multi-parameter which can be freely combined based on user’s requirements; ? Advanced technology for ensuring no cross contamination; ? Testing results is not connected with color and turbidity; ? Auto-calibration for keeping consistency and reliability; ? Patent water collecting technology, no blocking pipeline; ? Little reagent consumption, low cost; ? Easy to maintain( month/times), little work load, ahead of other products; Specifications Item Specifications Principle (ASV) Measuring range (As):1.0µg/L ~10.0mg/L (Cu):0.5µg/L ~20.0 mg/L (Hg):1.0µg/L ~10.0 mg/L (Zn):1.0µg/L ~25.0 mg/L (Cd):0.5µg/L ~25.0 mg/L (Pb):0.5µg/L ~25.0 mg/L Measuring Accuracy = ±5%; Analysis module Expanded to 3 channels Calibration Automatic calibration Measuring time 2-15mins (based on the sample concentration) Operating system Windows 2000 or above CU High-equipped computer Display 17cun display with big LCD screen Communication Interface RS232/RS485/4-20mA Communication Module GPRS optional Pre-handling Samples dispeller for option Power 300VA Power supply AC220V, 50Hz Size 600 x 450 x 1200 mm (L×W×H) weight <75kg Installation Cabinet type Professional Environmental Monitoring Solutions 15 Applications ? Tap water monitoring; ? Administration management on environmental protection; ? Pollution discharge monitoring; ? Auto-monitoring station on water quality; ? Large-scale aquaculture; ? Scientific research institutions and universities; 2.E6861 Water Quality Online Automatic Monitor for Chromium Introduction Using diphenylcarbazide hydrazine colorimetry to automatic monitor the total chromium / hexavalent chromium pollution degree and concentration index in water samples. It is widely used in water quality of the environmental monitoring, pollution emission monitoring and industrial process control and other fields. Features ? Advanced photoelectric quantitative techniques. ? Dual optical path loop monitoring technology automatically compensates for high measurement accuracy. ? Unique technology of pressure transmission and peristaltic pump of low flow, gas-liquid separation, corrosion preventive. ? Chromogenic reaction, colorimetric monitoring integrated design, simplify flow path, improve the stability. ? Configuration touch screen, humanity design. ? Over 10,000 data storage capacity, won’t be loss when power breakdown. ? Auto-alarm when malfunction or exceptional value. ? Self-protection and auto-restoration when it in the situation of power outage, water-break and auto-restored function. ? Manual operation, auto-correction, remote correction and auto-cleaning. ? Remote setup and diagnosis, easy to maintain. ? The veracity, safety and completeness of data, system stability will be guaranteed by the controller at technical grade. Professional Environmental Monitoring Solutions 16 Specifications Item Specifications Monitoring range 0~5.00mg/l(made by custom demand) Degree of precision =5% Degree of accuracy =±5% Repeatability =3% Linearity =5% Zero drift =±5% F•S Range drift =±5% F•S Response time =25min Practical sewage contrast test =10% Average non-failure operation time =1440h/times Analog output 4~20mA Communication interface RS485/RS232 Display Configuration touch LCD Power Average power is about 50W,maximum power is 100W Size (W×H×D)500mm×800mm×400mm Weight 40kg C. ZZW-Site Multi-parameter Water Quality Tester (Fast Detection) Introduction Based on the colorimetric analysis and the basic principles of value transfer, the site multi-parameter tester which integrates the KBC series vacuum test tubes (self-priming quantitative sampling), quantitative chromomeric technology with photoelectric sensors and digital-analog conversion technology together to develop the microcomputer-based site water quality tester, which can rapid qualitative and quantitative analysis of more than 50 kinds of chemical constituents from the water sample. The tester mainly composes tow parts—the test tube and the measuring instrument, can be expanded the functionality by the laptop computer. ? The test tube can automatically complete quantitative sampling and color reaction; ? Directly display and save the test sample results by Press “OK” button 4 times ; ? Real-time transfer the real-site data through the management software and network on control laptop computer Professional Environmental Monitoring Solutions 17 Features ? White light irradiation and visible wavelength spectrum collection, which really show the full test tube color reaction information and avoid the un-stability of traditional incident monochromatic light method. Increase the color recognition accuracy, which also ensure the stability of the instrument in any situation. ? Equally distributed sensor chip array can clear up site error of color tone, especially for the solution with small floats having no accuracy interference, which suits for site rapid determination of complex samples. ? The reference zero-free processing technology of micro-computer controller, overcomes the drift due to temperature, moisture, mechanical shock, improves the stability and accuracy of measured data. ? The establishing of working curve mathematical model makes the intelligent analysis of the parameters concentration, no calibration, no manual calculations for the test results. ? To start the instrument without preheating, menu options, buttons operation, man-machine interaction, the entire testing procedure is simple and straightforward. ? The instrument has display, store, checking, upload and other functions; which can connect with computer and using the special software for the on-site water quality data detection network transmission and management. ? Combine modular design, AC-DC power supply, non- maintenance, easy to carry. Specifications Item Specifications Test Range 350-750nm visible wavelength Display interface 128x64 dot matrix structure, LCD display, English menu-select Operational Panel 3x3 total 9 buttons, up, down, left, right and confirm button(OK), page Professional Environmental Monitoring Solutions 18 up/down button, escape button and menu button Power Supply 5 PCS of Alkaline AA battery, which can work for over ten hours& be changed at anytime; or 220V AC power supply Data Interface Can directly write to the flash disk Data Management With the display, store & checking etc. functions, can store 1000 PCS of data. Working Temperature 0-40°C,With the max 90%RH, non-condensing Dimensions L x W x H=195x120x65(mm) Basic Configuration ZZW-II Universal Type which has one tester, 20 boxes of testing tubes and 1 set of heating reactor ZZW-II Standard type which is based on the universal type and adds a laptop computer& one management software KBC Series Water Quality Rapid Test Tube Introduction The test tube which is based on the colorimetric analysis of Bouguer-Lambert-Beer law, integrated vacuum process design. Integrate the laboratory complex and cumbersome steps in the test tube, which can offer simple, fast detection methods and tools for the water quality analysis. Features ? The test tube adapts automatic quantitative sampling technology, which makes the highly professional testing work to the popularization test products, avoids the artificial operation error, and can quickly reflect the real situation of the water quality; ? Strict quality control in the tube production process which will effectively guarantee the performance of each batch of products with high degree consistency and test precision, avoid the complex procedure traditional testing method and maximum simplify the testing process; Professional Environmental Monitoring Solutions 19 ? Each of the test tubes is independent vacuum packaging, enforcing the automatic quantitative sampling and extending the product shelf life at the same time, which avoids wasting the unused breaking reagent and reduces the testing cost; ? Use small amount of reagents, and not directly touch the human body, the recycle test tubes will not make a secondary pollution; ? Now we have various parameters and specifications test tubes for the customers to choose, which basically cover the common water pollutants. With appropriate preparation technology, the product can also be applied to broader areas such as food, soil, oil field; Specifications Item Tube Name Dimension& Type Test Range(mg/L) Detection Limit( mg/L) Warranty Time(Years) 1 DO(High) KBC—DO—1.0 0.5—12 0.5 3 2 DO(Medium) KBC—DO—0.1 0.1—1.0 0.1 3 3 Sulfide(low) KBC—S2—0.1 0.1—1.0 0.1 1 4 Sulfide(high) KBC—S2—1.0 1.0—20 0.5 1 5 Ammonia Nitrogen KBC—NH3-N 0.3—25 0.2 1(4?) 6 NOxN KBC—NO3—N 10—45 2.0 1 (4?) 7 High Nitrite Nitrogen KBC—NO2—N-1.0 0.5—4.0 0.2 1 8 Low nitrite nitrogen KBC—NO2—N-0.1 0.1—1.0 0.03 1 9 Phosphate KBC—PO43—P 0.5—5.0 0.05 1 (4?) 10 Cyanide KBC—CN- 0.01—0.2 0.005 2 11 Fluoride KBC—F- 1.0—10 0.5 1 (4?) 12 Cupric KBC—Cu2+ 1.0—30 0.2 1 (4?) 13 Cadmium Ion KBC—Cd2+ 0.1—0.5 0.05 1(4?) 14 Nickel ions KBC—Ni2+ 0.6—4.0 0.1 1 15 Hexavalen Chromium KBC—Cr6+ 0.3—6.0 0.05 1(4?) 16 Lead Ion KBC—Pb2+ 2—15 0.5 1(4?) 17 COD(low) KBC—CODcr—(Low) 50—500 20 1(4?) 18 COD(Medium) KBC—CODcr—(Medium) 200—1000 50 1(4?) 19 COD(high) KBC—CODcr—(High) 300—3000 200 1(4?) Professional Environmental Monitoring Solutions 20 20 Volatile Phenol KBC—C6H5OH 1.0—10 0.2 1(4?) 21 Arsenic Compound KBC—As5+ 1.0—10 0.2 1 22 Chloride KBC-CL-100 50-400 30 1(4?) 23 Bivalent Mercury KBC—Hg2+ 1.0—10 0.5 1(4?) 24 Cobalt KBC—Co2+ 0.3—3.0 0.1 1 25 Manganese KBC—Mn 1.0—20 1.0 1 26 pH KBC—PH—I 0.2—2.0 1 27 pH KBC—PH—? 4.0—9.0 1 28 Vitriol KBC—H2SO4 0.05—1.4 (mol/L) 0.03(mol/L) 1 29 Formaldehyde KBC—HCHO 1.0—10 0.5 1(4?) 30 Aniline KBC—C6H7N 0.5—2.0 0.2 1(4?) 31 Chlorine Dioxide KBC—ClO2 1.0—10 0.5 1 32 High Residual Chlorine KBC—Cl2-1.0 1.0—14 0.2 1 33 Lead KBC—Pb2+ 2—15 0.5 1(4?) 34 Ferrum KBC—Fe 1.5—30 1.2 2 35 Ferrous KBC—Fe2+ 0.2—28 0.14 2 Professional Environmental Monitoring Solutions 21 Specifications A. To perform a test, immerse the test tube into the sample and snap off the tip, the correct volume of sample is automatically drawn in, filling the tube; a small inert gas bubble remains in the tube; B. To facilitate mixing the sample and reagent, tilt the tube back and forth so the bubble travels from end to end several times, make the color reaction complete; C. Insert the test tube into the tester jack, press the buttons& read the information. 1.ZZW Portable COD Tester Technical Parameters Item Parameters Testing Parameters High COD Medium COD Low COD Test Range(mg/L) 300-3000 200-1000 50-500 A B C Professional Environmental Monitoring Solutions 22 Detection Limit(mg/L) 200 50 20 Reaction Time 10min(High, Medium), 40min(Low) Salt Resistance CL-=15,000mg/L Display Interface 128x64 dot matrix structure, LCD display, English menu-select Power Supply 4 PCS of Alkaline AAA battery, which can work for over ten hours& be changed at anytime; or 220V AC power supply Data Management With the display, store& checking etc. functions, can store 1000 PCS of data Working Temperature 0-40°C, Max 90% RH, non-condensation Dimension (mm) L x W x H==160 x80 x 60(mm) 2.ZZW Portable Heavy Metals Tester Technical Parameters Item Parameters Testing Parameter Hg2+ Pb2+ Cd2+ Cr6+ Cu2+ Ni2+ Mn2+ Total Fe2+ Fe2+ Co2+ Test Coverage(mg/L) 1.0-10 2.0-15 0.1-0.5 0.3-6.0 1.0-30 0.6-4.0 1.0-20 1.0-30 1.0-28 0.3-3.0 Detection Limit(mg/L) 0.5 0.5 0.05 0.05 0.2 0.1 0.4 0.5 0.14 0.1 Display Interface 128x64 dot matrix structure, LCD display, English menu-select Power Supply 4 PCS of Alkaline AAA battery which can work for over ten hours& be changed at anytime; or 220V AC power supply Data Management With the display, store& checking etc. functions, which can store 1000 PCS of data Working Temperature 0-40°C, Max 90% RH, non-condensation Professional Environmental Monitoring Solutions 23 Dimension (mm) L x W x H=160 x80 x 60(mm) 3.ZZW Portable Toxic Tester Technical Parameters Item Parameters Testing Parameter CN- High NO2- Low NO2- As5+ C6H5OH HCHO N2H2 F- Testing Range(mg/L) 0.01-0.20 0.5-4.0 0.1-1.0 1.0-10 1.0-10 1.0-10 0.1- 50 1.0- 10 Test Limit(mg/L) 0.005 0.2 0.03 0.2 0.2 0.5 0.05 0.5 Display Interface 128x64 dot matrix structure, LCD display, Chinese menu-select Power Supply 4 PCS of Alkaline AAA battery, which can work for over ten hours& be changed at anytime; or 220V AC power supply Data Management With the display, store& checking etc. functions, can store 1000 PCS of data Working Temperature 0-40°C, Max 90% RH, non-condensation Dimension (mm) L x W x H =160 x80 x 60(mm) Professional Environmental Monitoring Solutions 24 4.ZZW Portable Residual Chlorine Tester Technical Parameters Item Parameters Testing Parameter Low CL2 High CL2 CLO2 Testing Range(mg/L) 0.1-1.5 1.0-14 1.0-10 Testing Limit(mg/L) 0.05 0.2 0.5 Display Interface 128x64 dot matrix structure, LCD display, English menu-select Power Supply 4 PCS of Alkaline AAA battery, which can work for over ten hours& be changed at anytime; or 220V AC power supply Data Management With the display, store& checking etc. functions, which can store 1000 PCS of data Working Temperature 0-40°C, Max 90% RH, non-condensation Dimensions(mm) Lx W x H =160 x80 x 60(mm) 5.ZZW Portable DO Tester Professional Environmental Monitoring Solutions 25 Technical Parameters Item Parameters Test Parameter High Dissolved Oxygen Medium DO Low DO Test Range (mg/L) 0.5-12 0.1-1.0 0.01-0.10 Detection Limit(mg/L) 0.5 0.1 0.01 Test Time =2min Salt Resistance CL-=20,000mg/L Display interface 128x64 dot matrix structure, LCD display, English menu-select Power Supply 4 PCS of Alkaline AAA battery, which can work for over ten hours& be changed at anytime; or 220V AC power supply Management With the display, store& checking etc. functions, which can store 1000 PCS of data Working Temperature 0-40°C, Max 90%RH, non-condensation Dimension (mm) L x W x H=160 x80 x 60(mm) Professional Environmental Monitoring Solutions 26 Chapter 2 Gas Quality Monitoring 1. AS2000 Continuous Emission Monitoring System Introduction AS-2000 comprises sampling subsystem, gas measuring subsystem, smoke measuring subsystem, auxiliary parameter measuring subsystem, data collecting and handling subsystem, blowback subsystem and other monitoring subsystem, which can continuous monitoring SO2, NOX, 02, SO2,NOX,O2,CO,CO2,NH3,HF, HCL, PM10, flow rate of exhaust gas, temperature, pressure, humidity and other gas parameters, the ratio and volume doses of emission will be calculated, printed, displayed, managed, and transferred to relevant department by data and textual pattern transmission system. AS-2000 Continuous Emission Monitoring System is mainly used stack gas monitoring of boiler, kiln, refuse burning and etc. Crucial parts of this system are the advanced diode array fiber-optics spectrophotometers and laser dust density monitor, processing all intellectual property rights of the core instrumentation. CEMS – schematic Diagram ??: Discharge; ??:Temperature; ??: Pressure; ??:Dust; ???: Hub; ????: Probe Sampling; ????: Heat Pipe ???: Signal Lines ???: Power Line ???: Distribution Cabinet ????: Communications Network ???????: EPA Control Center ??????:Corporation Control Center Professional Environmental Monitoring Solutions 27 Features ? Automatic analyzing the concentration of one or more components of the concentration of SO2,NO,CO,CO2,O2,C2H4 and gaseous pollutant in the mix gas, but also detecting the discharge flue dust in the fume and the monitoring of process parameters; ? Measuring results will be stored in the data sampling control system automatically; ? All kinds of ways of transmission can be compatible, multi-levels networking; ? Standard modular design, easy to maintain, upgrade and expand; ? CEMS system can be self-diagnosed, including invalid probe and detecting source, range exceed alarm, breakdown of main units alarm, timely fault notice during the operation; ? Site data timely transferred, fault remote diagnosis; ? Auto-calibration zero by air(<3%CO2 must use N2 calibration zero); ? Data can be collected, stored, handled and distinguished by data system, which can control the daily construction of CEMS, including cycling auto-correction, auto-reverse blowing probe and filter of sampling system, providing the information what approved test and monitoring needed; ? Multichannel 4~20MA analog output and relay contact output; ——high-accuracy, stable ——short preheating time-5mins ——bilingual menu operation ——User can do the man-machine interaction through keyboard and LCD in the front ——system can non-stop operate at least 90 days with no need for daily maintenance ——Interval time: one adjusting every 1-6 months according to environmental condition ——easy to use, operate and set, low-cost, low work load for maintain Specifications Item Specifications Measuring elements SO2,NOx or O2 (according to user’s requirements, no O2 sometimes) Measuring range SO2 0 ~ 2500mg/m3 NOx 0 ~ 2500 mg/m3 O2 0 ~ 25vol% Repeatability Each gas component, respective range±0.5%(FS) Digital display drift Each gas component, respective range within ±1% Zero drift Each gas component, respective range within ±2%/weeks Drift Each gas component, respective range within ±2%/weeks Linearity Each gas component, respective range within ±2%/ Response time Each gas component, its respective measuring range within 100 seconds, but SO2 within 240 seconds Stability relative to ambient temperature The temps changes within ±5?, satisfied the specified value of zero drift and span drift Quantity of sample About 3L/min Method of correction manual automatic:(0~999 hour) Professional Environmental Monitoring Solutions 28 Gas revise Zero gas 100%N2 standard gas Span gas SO2 in N2 standard gas NO in N2 standard gas O2 in N2 standard gas or air) Enable condition Temp.:-5 ~ 40?.Humidity:95%RH below, no radiation Direct sunlight, the place with more vibratory External input and output Applied in the circumstance of power-off, maintenance, analyzer alarm, correction and others Voltage AC380V±22V,50/60Hz(optional)about 40A size overall dimension drawing for reference weight About 200Kg Material of connected parts Polyethylene, glasses, Teflon, Viton Await sample gas pressure -1Kpa ~ +1Kpa Standard sample gas Temp.:400? below Dust:0.1g/Nm3 SO2:2500mg/m3 below NOx:2500 mg/m3 below H2O:0.8 ~ 80wt% Storage Surrounding Temp.:-20 ~ 60? Humidity:60% below Others: cannot be stored in the air of corrosive ( shall open the package, on the breezy place Applications Monitoring the waste gas emission from Power Generation, Thermal Power, Iron and Steel, Petrochemical, Cement, Waste Power, Desulphurization and Denitrification, Tobacco, Paper and so on. 2. CPR-100 Portable Multi-gas Detector Introduction CPR-100 Portable Multi-gas Detector (Electronic Nose)is a combined product of sensor technology, electronics and computer based on the animal olfactory sensation principle, composed of part selective electrochemical array sensor and its relevant pattern recognition system, bionic gas analyzer of distinguishing simple or complex smell. Professional Environmental Monitoring Solutions 29 Features ? Easily detect hundreds of gas with one machine, without replace any accessories; ? Fast detect unknown gas especially gas concentration; ? Easy to use, small sized, intelligent; ? Without interference between gases, free of weather influence for alarming; ? High-capacity, real time storage; ? Data can be downloaded through upper software, automatically producing curve, average value and diagrams; ? Intelligent unique learning, can add the type of gas what is not be the database into database; ? Auto-monitoring, can be connected unite alarm network or commander center, realizing early alarming long-distance, remote communication and control; ? Simple maintained, no need maintenance with one year; ? Two operational ways of on-line and man-pack; Professional Environmental Monitoring Solutions 30 Specifications Item Specifications Operating Temp. -20-50ºC Storage temp. -20-50ºC Operating humidity =15%-95%RH non-condensed Linearity ±2%F.S Accuracy ±5%F.S Zero drift ±2%F.S Response time <30s Range drift ±2%F.S Flow of gas sample 300ml/min Working life of sensor >2 years Way of sampling Absorb pump Flow of dust sample 5.0L/min or 600ml/min Communication interface RS485 and USB data transferred interface power supply mode Lithium battery(3.6V*3) outer A.C.(AC220V 50Hz 1.0A) Operating life of battery continuous 8 hours Charging time 10 hours size 300 x 260 x 490mm Weight 15kg Computer system Features Distinguish Communication Sensor array Gas sample system Sensor 1 Sensor 2 Sensor 3 Sensor 4 Signal pretreatment Commander Professional Environmental Monitoring Solutions 31 Unit: ppm or mg/m3 customer-made Type of gas Measuring range Resolution ratio Carbon Monoxide 0-500 1 Hydrothion 0-100 1 Chlorine 0-100 1 Sulfur Dioxide 0-100 1 Hydrogen Fluoride 0-50 1 Ammonia 0-100 1 Combustible Gas 0-100%LEL 0.5%LEL Nitrogen Dioxide 0-100 1 Oxygen 0-30%VOL 0.5%VOL Hydrogen Cyanide 0-100 0.1 Hydrogen Chloride 0-30,100 0.1 Ethene 0-20,100 1 Hydrogen 0-1000,4%vol 1, 10 Nitric Oxide 0-300,1000 1 Fluorine 0-10 0.1 Bromine 0-30 0.1 Hydrogen Phosphide 0-20,1000 0.1 Acrylonitrile 0-20,100 1 Acetic Ether 0-20,100 1 Chlorine Dioxide 0-10,100 0.1 Ethylene Oxide 0-20,100 1 Silane 0-20 0.1 Ethyne 0-20,100 1 Carbon Dioxide 0-5%vol,100%vol 0.01%vol Arsenic Hydride 0-5 0.01 THT 0-100 1 Hydrogen Bromide 0-30 0.1 Unsymmetrical Dimethylhydrazine 0-5,20,100 0.01 Phosgene 0-5 0.01 VOC 0-2000,5000 1 Phosphorus Oxychloride 0-30 0.1 Applications Environmental Monitoring Industry: monitoring and analysis on on-site emission of pollution source, emergency site, workplace safety and pollution gas. Protection of security Industry: monitoring of explosion matter, poison gas, public place, ports and buildings security, anti-terrorism and criminal investigation. Petroleum and Chemistry Industry: oil reveal, emergency, pipeline transportation, analysis on oil elements. Professional Environmental Monitoring Solutions 32 Fire-fighting Industry: all kinds of harmful or inflammable gas will be detected rapidly by the electronic nose when fire accident happened. Food Safety Industry: pharmacy, disease prevention and control center, gas analysis in lab. 1. Portable Gas Analyzer Introduction Features ? LCD, Auto-backlight; ? Auto-monitoring with Long Life Re-chargable Batteries; ? Data logging and 232 Output Capability; ? Simple correction program, auto-calibrated zero after starting up; ? Easily set up the value of alarming by function button; ? Auto-transferred between the concentration of ppm and mg/m3 through menu ? Low power, easy to use and transfer between battery and sensor. Specifications Item Specifications Poison gas/Oxygen monitoring theory electrochemistry Carbon dioxide monitoring theory infrared ray Combustible monitoring theory infrared ray / catalytic combustion Way of monitoring diffusion type or absorbed pump, dismounting at will Response time T90 electrochemistry <60 sec, infrared ray <10 sec, catalytic combustion <15sec Accuracy ±5%F.S. Professional Environmental Monitoring Solutions 33 Operating temp from -20? to +50? Operating humidity 15%-95% relatively humidity(no condensation) LCD Display display concentration value, time, date Backlight auto-opened when light darks or alarm or pressing the bottom Function test self-checking after starting-up Alarm alarm level can be set up arbitrarily, sound and light alarm(sound80dB) Standardization Boot zero calibration and standard gas of two-point correction Concentration unit easy transformation between ppm and mg/m3 Battery lithium battery, continuous working above 10 hours Life of battery can use replaceable battery, service life >2 years Level of protection IP65 Size 104mm×62mm×34mm (length ×width × thickness) Weight 0.3kg Catalogue of Portable Gas Analyzers Name Sensors’ working life Monitoring Range (Unit: mg/m3) Resolution Ratio (Unit: mg/m3) Form aldehyde Analyzer >2 years 0-10 0.01 0-100 0.1 Toluene Analyzer >2 years 0-10 0.01 0-100 0.1 Ammonia Analyzer >2 years 0-100 0.1 0-1000 1 Oxygen Analyzer From 2 to 4 years 0-25% VOL 0.1% VOL Carbon Monoxide Analyzer 5 years 0-1000 1 0-2000 1 Ozone Analyzer >2 years 0-5 0.01 0-100 0.1 0-1000 1 Hydrogen Sulfide Analyzer 5 years 0-100 1 0-1000 1 Chlorine Analyzer >2 years 0-100 0.1 Hydrogen Analyzer >2 years 0-1000 1 0-4% VOL 0.04% VOL Hydrogen Cyanide Analyzer >2 years 0-100 0.1 Hydrogen Chloride Analyzer >2 years 0-100 0.1 Professional Environmental Monitoring Solutions 34 Ethylene Analyzer >2 years 0-100 1 Sulfur dioxide Analyzer >2 years 0-100 0.1 nitric oxide Analyzer >2 years 0-300 1 Nitrogen Dioxide Analyzer >2 years 0-100 0.1 Hydrogen-fluoride Analyzer >2 years 0-10 0.1 Fluorine Analyzer >2 years 0-10 0.1 Bromine Analyzer >2 years 0-30 0.1 Hydrogen Phosphide Analyzer >2 years 0-20 0.1 0-1000 1 Ethanol Analyzer >2 years 0-100 1 Acrylonitrile Analyzer >2 years 0-100 1 Ethylene Oxide Analyzer >2 years 0-100 1 Ethyl acetate Analyzer >2 years 0-100 1 Combustible Analyzer 5 years 0-100%LEL 1% LEL 3 years 0-100%LEL 1% LEL Chlorine Dioxide Analyzer >2 years 0-10 0.1 Applications Closed Space Gas Monitoring;Petroleum, Metallurgy, Papermaking industry;Industry Security Monitoring;Hazardous Substance Monitoring; 5. CPR-KA Mobile Air Quality Monitoring System Introduction CPR-KA Air Quality Monitoring System consists of SO2 analyzer, NOX (NO2/NO) analyzer, O3 analyzer, CO analyzer, PM10 analyzer, VOC analyzer, THC analyzer and meteorological multi-parameter monitor, etc. CPR-KA Air Quality Monitoring System is developed with international electronic technique and network communication based on the fixed electric potential electro-analysis principle, monitoring of polluted gas, light scattering principle and ß ray method. Professional Environmental Monitoring Solutions 35 Features ? Rational design, easy to be used as a portable or automatic continuous online monitoring instrument; ? Easy to monitor all Gas parameters and PM10 whose value will be shown on the screen as well; ? Automatic sampling and analyzing continuously when it used as back pack instrument; ? High-sensitivity sensor, rapidly response, high resolution ratio, Detecting inferior limit can be achieved ppb; ? Measured concentration value can be realized through switchover among mg/m3,ppm,ppb with trends graphs; ? Display with graph screen, directly shows all kinds of inspection data, graphs and machine status, providing friendly man-machine talk interface; ? SCM( single-chip microcomputer) mixed with internet communication along with the function of data storage, providing convenient way of data inquiry, also can transfer the data to computer by USB, its daily average value, monthly average value, and pollute index can be auto-calculated by upper computer software, printed in different kinds of graphic data. ? Lithium battery or outer A.C., if power-off, the battery can be worked for 8 hours continuously. ? Stable, high-accuracy, easy to use and maintain protection when power-off. Professional Environmental Monitoring Solutions 36 ??: Gas Sample; ???:Sensor; A/D ???: A/D Adapter; CPU ?????:CPU; ????: Communication Interface; ????: Operation Interface; LCD ?????:LCD; ??: Storage; ???: Sucking Pump; ?????: Flow Regulator; ??:Power; ??: Charge Specifications Item Specifications Operating Temp. 5-40ºC Storage Temp. -20-40ºC Operating Humidity =15%-85%RH no condensation Linearity ±2%F.S Accuracy ±2%F.S Zero Drift ±2%F.S Response Time <150s Range Drift ±2%F.S Flow of Gas Sample 300ml/min Working Life of Sensor >2 ? Way of Sampling Absorb Pump Flow of Dust Sample 5.0L/min or 600ml/min Communication Interface RS485 and USB Interface Power Supply Mode Lithium battery(3.6V*) Outer A.C.(AC220V 50Hz 1.0A) Operating Life of Battery Continuous 8 hours Charging Time 10 hours Size 300 x 260 x 490mm Weight 15kg Professional Environmental Monitoring Solutions 37 Gas Monitoring Parameters: Monitoring Parameters Monitoring Range Resolution Ratio SO2 0-2ppm 0.001ppm NO2 0-2ppm 0.001ppm O3 0-5ppm 0.001ppm CO 0-50ppm 0.1ppm H2S 0-2ppm 0.01ppm HF 0-2ppm 0.01ppm Other Gas Customer-made Parameters of monitoring particulate matter what can be absorbed: Monitoring Range Resolution Ratio 0-100mg/m3(optional) 0.01 mg/m3 0-10mg/m3(optional) 0.001 mg/m3 PM10,PM5 and PM2.5 Cutter for choice Applications Urban atmospheric environment monitoring, Corporate environmental monitoring, Non-organizational pollution gas emission monitoring, Environmental assessment monitoring. Chapter 3 Noise Monitoring 1. Sound Level Meter AWA6228 Features ? A pocket real-time noise signal analyzer ? 100 dB(AWA6228)Level Linearity Range ? Different software could be selected ? Auto-start and auto-end Uses ? Precision acoustics measurements ? Real-time frequency analysis in 1/1 and 1/3 octave digital filters ? Environmental noise measurement and 24 hour monitoring ? Reverberation time measurements ? Airport Noise Monitoring and data collect Professional Environmental Monitoring Solutions 38 Specifications: Fulfils Standards IEC 61260 class 1 Microphone 1/2" Prepolarized Condenser Mic. Model AWA14425 (sensitivity : 40 mV/Pa) Preamplifier AWA14601 Frequency Range 10 Hz ~ 16 kHz Self-generated Noise <20 dB(A), 25 dB(C), 30 dB(Z) Meas. upper Range 125 dB Peak C Sound Level Measuring Range 40 ~ 128 dB Frequency Weighting. Parallel (simultaneous) A, C, Z. Realized by digital filtering Time Weighting Parallel F, S, I, Peak A/D Bits 24 bits Level Linearity Range >100 dB Sampling Frequency 48 kHz Display 128×128 graphic LCD, with LED back-lit Display Refresh 1 Hz for value; 10 Hz for graph Main Parameters of Integrating Measurement Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT. Note: X is A, C, Z and Y is F, S, I. Main Parameters of Airport Noise Meas LEPN,Td,Lmax Display Resolution 0.1.dB Real-time Analysis Speed Approx. 47 times / s (It can simultaneously complete all center frequencies and A, C, Z weighting.) Statistical analysis Statistical analysis software(S6228-00101) Professional Environmental Monitoring Solutions 39 Function The statistical analysis menu: LAFp, LAFmax, LAF5, LAF10, LAF50, LAF90, LAF95, LAFmin, SD, LAeq1 s, LAeq, T, LAE, LAFeqT. 24h measures menu: And Ld, Ln, Ldn. Real-time spectrum analysis Fulfils standards:, IEC 61260 Class 1 Filter type: Digital band-pass filter Measuring Parameters: Lfmi, Lfmeq,1s, Lfmeq,T, Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm. Note: fm is center frequency; X is frequency weighting A, C, Z. Y is time weighting F, S, I Real-time 1/1 OCT spectrum analysis 1/1 OCT spectrum analysis software(S6228 -00202) Filters Center. Frequency :16 Hz~16 kHz. Real-time 1/1 OCT spectrum analysis 1/3 OCT spectrum analysis software(S6228 -00303) Filters Center Frequency 12.5 H~16 kHz Reverberation time measurement function 1. Function:Reverberation time?EDT measurement by integrated impulse response method 2. Fulfils Standard:ISO 3382 3. Measuring Parameters:T20?T30?EDT 4. Measuring Range:0.20 s to 20.00 s 5. Wave record time:10 s or 20 s 6. Bandwidth of digital filters:1/1 OCT or 1/3 OCT 7. Center Frequency Ranges: 63 Hz ~ 16 kHz for Oct., 40 Hz ~ 16 kHz for 1/3 Oct. 8. Date store :Max 128 groups Data Storage maximum 128 groups, The measuring results can be stored in SD Integral Time Manual, 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1h, 4h, 8h, 24h or 1 min~59 min Print Can print analytical results in the mini-print, can also print the contents showed on LCD Data Recall Recalled any data Intelligent Delete Burst event may be deleted scientifically Professional Environmental Monitoring Solutions 40 Internal Clock Error less than 1 min/month Output Interface AC Output: ,f3.5 mm stereo plug DC Output : DB-9 plug RS232 Interface: to the mini-printer, or connected to PC. USB Interface: Available as USB interface when SD card has be selected Power Supply 4×LR6 alkaline battery or rechargeable batteries, which can work for over 18 hours continuously. 5 V external power supply is also acceptable Dimensions 260 (H) x 80 (W) x 30 (D), mm. Weight 0.35 kg. (include batteries) EMC Type X Working Temperature -10 ~ 50 ? Relative Humidity 25 ~ 90 % Atmospheric Pressure 65 kPa ~ 108 kPa Optional functions 1. SD card 2.GPS module 3.Recording( have to choose SD card first) 1)Recording format : sampling frequency 48000, 16bit precision 2)File format: WAV, including calibrating information 3)Recording time: 1s to 1h 4)Replay: either by instrument or via PC 2.Sound Level Meter Model AWA5661 Features ? Latest Digital Signal Processing Technology ? Wide Dynamic Range ? Modular Design - on Demand Selection ? Wide Warm Design, Operating Temperature from -15 0C to 50 0C ? Complies with IEC 61672 Class 1 Uses ? Widely use in Industrial Noise Surveys ; machinery, vehicles, ships and etc ? May also used in Ambient Noise Professional Environmental Monitoring Solutions 41 Specifications: Items AWA5661-1 AWA5661-1A AWA5661-1B AWA5661-1C AWA5661-2 AWA5661-3 Microphone AWA14425 AWA14423 AWA14411 AWA4431 AWA14425 Sensitivity -30dB -28 dB -25dB -50dB -30dB Frequency Weighting A?C?Z Time Weighting F?S?I?Peak Frequency Range 10Hz~16kHz 10Hz~ 20 kHz 10Hz~ 16kHz 10 Hz ~ 20 kHz 10 Hz ~16kHz Meas. Upper Range >140dB >138dB >135dB >160 dB >140 dB Self-generated Noise <20dBA <18dBA <10dBA <40 dBA <20 dBA Display 128 × 64 LED Outputs AC?DC?RS 232 Sampling Frequency 48kHz Integrating No No No No Yes Yes Professional Environmental Monitoring Solutions 42 Function Integrating Time No Maunal,10s,1m,5m,10m,20m,30 m,1h,2h,4h,8h,12h,16h,24h 1s~24h Main parameters of measurement Lp,Lmax,Lpeak Lp,Lpeak,Lmax,Lmin,SEL,E LFp,LSp,LIp,Leq,t,Lpeak,Leq,T,LFmax,LFmin,LSmax,LSmin,LImax,LImin,SEL,Lex8h,LAVG,TWA,DOSE,L5,L 10,L50,L90,L95,SD,Ts,Tm,Volt,Date,Time,E. Statistical analysis function No Optional (software authorized) Yes Over limit indication Yes, Limits can be settled Data Storage No Yes,8000 Groups Recoding Function No Optional(software Authorized) Working Temperature -15 ?~50 ? Specialty Precision pulse Wide Bandwidth Low noise measurement High noise measurement Precision integral Super function 3.Sound Level Meter Model AWA5636 Features Latest digital signal processing technology Wide dynamic range High precision ? Modular design - on demand selection ? Wide temperature design, Operating temperature from -15 ? to 50 ? ? Complies with IEC 61672 class 2 Professional Environmental Monitoring Solutions 43 ? Uses ? Widely use in industrial noise surveys ; machinery, vehicles, ships and etc ? May also used in environmental noise Items AWA5636-0 AWA5636-1 AWA5636-2 AWA5636-3 AWA5636-4 Microphone AWA14421 Sensitivity -30dB -28 dB -25dB -50dB -30dB Frequency Weighting A?C?Z Time Weighting F?S F?S?I F?S?I?Peak Frequency Range A A,C,Z A,C,Z A,C,Z A,C,Z 20 Hz~12.5 kHz Meas. Upper Range 30dB Self-generated Noise <30dBA <25dBA Display 128 × 64 LED Outputs AC,DC AC,DC,RS232 A/D Bits 32kHz Integrating Function No Yes Measure Parameters Lp,Lmax Lp , Lmax , Lmin,SEL,E Lp,Leq1s LFp,LSp,LIp,Leqt,Lpeak,Leq,T,LFmax,LFmin , LSmax , LSmin , LImax , Professional Environmental Monitoring Solutions 44 LImin , SEL, Lex8h ,LAVG,TWA,DOSE,L5,L10,L50,L90,L95,SD,Ts,Tm,Volt,Date,Time, Statistical analysis function No Optional , L5,L10,L50,L90,L95,SD No Yes Integral Time No Manual,10 s,1 m,5 m,10m,20 m,30 m,1 h,2 h,4 h,8 h,12 h,16 h, 24 h Manual,10 s,1m,5 m,10 m, 20 m, 30 m,1h,,2 h,4 h,8 h ,12 h , 16h,,24 h 1s~24h RS232 Interface No Optional Yes,with software USB Interface No Optional Optional Optional Yes,with software Data Storage No Yes,8000 Groups Recoding Function No Optional(software Authorized) Working Temperature 0?~40 ? -10?~50? -20~50? -10?~50? 4.AWA6291Real Time Signal Analyzer Detailed Product Description Model AWA 6291 Real-time Signal Analyzer is a pocket real-time analyzer that can make analysis on the noise, vibration or other electrical signal including their frequency spectrum and amplitude value through the digital signal processing technology. Due to modularized design, you can select different software based on your specific needs; therefore it can realize diversified functions and obtain various measuring parameters. This analyzer can be widely used in the various fields such as environmental protection, labor hygiene, research and teaching, industrial enterprise, measuring and testing etc. It can realize the environment noise measuring, machines noise analysis, sound power level measuring, building acoustics measuring, as well as vibration measuring and analysis. Features ? A pocket real-time noise signal analyzer Professional Environmental Monitoring Solutions 45 ? FFT analysis on noise or vibration(AWA6291) ? 90dB Level Linearity Range ? Different software could be selected ? Auto-start and auto-end Uses ? Precision acoustics measurements ? Real-time frequency analysis in 1/1 and 1/3 octave digital filters ? Environmental noise measurement and 24 hour monitoring ? Reverberation time measurements ? Airport Noise Monitoring and data collect Fulfils Standards IEC 61672 class 1 Microphone 1/2" Prepolarized Condenser Mic. Model AWA14423 (sensitivity : 50 mV/Pa) Preamplifier AWA14601 Frequency Range 10 Hz ~ 20kHz Range Gain -10 dB, 0 dB, 10 dB, 20 dB, 30 dB, 40 dB.Range Error: =0.1 dB Self-generated Noise <18 dB(A), 23 dB(C), 28 dB(Z) Meas. upper Range 140 dB Peak C Sound Level Measuring Range 50 ~ 143 dB Frequency Weighting. Parallel (simultaneous) A, C, Z. Realized by digital filtering Time Weighting Parallel F, S, I, C+, Peak C? A/D Bits 24 bits Level Linearity Range >90 dB Sampling Frequency 48 kHz Display 240×160 graphic LCD, with EL back-lit Display Refresh 1 Hz for value; 10 Hz for graph Professional Environmental Monitoring Solutions 46 Main Parameters of Integrating Measurement Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak?, Cpeak?,LAFmax, LAFmin, LAFeqT, LASeqT, LAIeqT. Note: X is A, C, Z and Y is F, S, I. Main Parameters of Airport Noise Meas LEPN,Td,Lmax Display Resolution 0.1.dB Real-time Analysis Speed Approx. 47 times / s (It can simultaneously complete all center frequencies and A, C, Z weighting.) Statistical analysis Function Statistical analysis software (S6291-00101) Statistical analysis Menu: LAFp, LAFmax, LAF5, LAF10, LAF50, LAF90, LAF95, LAFmin, SD, LAeq1 s, LAeq, T, LAE, LAFeqT. 24 hours monitors menu :And Ld, Ln, Ldn Real-time spectrum analysis Fulfils standards:, IEC 61260 Class 1 Filter type: Digital band-pass filter Measuring Parameters: Lfmi, Lfmeq,1s, Lfmeq,T, Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak, Tm. Note: fm is center frequency; X is frequency weighting A, C, Z. Y is time weighting F, S, I Real-time 1/1 OCT spectrum analysis 1/1 OCT spectrum analysis software for noise (S6291 -00202) Filters Center. Frequency: 16 Hz~16 kHz. Real-time 1/1 OCT spectrum analysis 1/3 OCT spectrum analysis software(S6291 -00303) Filters Center Frequency 10 Hz~20 kHz FFT analysis function FFT analysis software for noise (S6291 -00404) 1. Line Number: 200 lines on the display. 2. Sampling Frequency: 48 kHz, 24 kHz, 12 kHz,6 kHz, 3 kHz, 1.5 kHz. 3. Upper Limit of Analysis Frequency: 18.75 kHz, 9375 Hz, 4687 Hz, 2344 Hz, 1172 Hz, 586 Professional Environmental Monitoring Solutions 47 Hz. 4. Bandwidth of each line: 93.75 Hz, 46.875 Hz, 23.438 Hz, 11.74 Hz, 5.8594 Hz, 2.9297Hz. 5. Average Method: index and linearity. 6. Measuring Parameters: Lxyp, Lxyi, Lxeq,1s, Lxeq,T, LAE, E, Cpeak,Tm in every line Reverberation time measurement function 1. Function:Reverberation time?EDT measurement by integrated impulse response method 2. Fulfils Standard:ISO 3382 3. Measuring Parameters:T20?T30?EDT 4. Measuring Range:0.20 s to 20.00 s 5. Wave record time:10 s or 20 s 6. Bandwidth of digital filters:1/1 OCT or 1/3 OCT 7. Center Frequency Ranges: 63 Hz ~ 16 kHz for Oct., 40 Hz ~ 16 kHz for 1/3 Oct. 8. Date store : Max 12288 groups reverberation time,also translate to U disc Data Storage 64M bits Flash, instantaneous data, 1 second integral results and integral measuring result (maximum 12288 groups). Also can be stored in Flash disk or transferred to the Flash disk through USB interface Integral Time Manual, 10 s, 1 min, 5 min, 10 min, 15 min, 20 min, 30 min, 1h, 4h, 8h, 24h or 1 min~59 min Print Can print analytical results in the mini-print, can also print the contents showed on LCD Data Recall Recalled any data Intelligent Delete Burst event may be deleted scientifically Internal Clock Error less than 1 min/month Output Interface Stereo Connector AC Signal Output RS 232 interface to the mini-printer, or connected to PC USB Interface, which can transfer the measuring results to PC, or the Flash disk. Power Supply 6 × LR6 alkaline battery or rechargeable batteries, which can work for over 12 hours continuously. 9 V external power supply is also acceptable Dimensions 310(H) × 90(W) × 38(D),mm Weight 0. 5 kg. (include batteries) EMC Type X Working Temperature -10 ~ 50 ? Relative Humidity 25 ~ 90 % Atmospheric Pressure 65 kPa ~ 108 kPa Professional Environmental Monitoring Solutions 48 Chapter 4 Remote Terminal Unit 1. Remote Terminal Unit E50 RTU Overview Super E50 series RTUs could realize industrial field signals acquisition and equipments control. They adopt advanced 32-bit ARM technology and efficient embedded operating system and the functions of the whole system are powerful, easy operation and high integration. They are not only competent in logic, timing, counting control, but also in data processing, high-speed counting, analog control, PID, RTD, TC, communication networking. Their programs facilitate development and could realize distributed control when combined by PC for make up a control system. Super E50 series RTUs have a variety of configurations and optional functions. They could be developed various control systems in different field according to the user’s practical needs. Architechture Professional Environmental Monitoring Solutions 49 Performance Features ? Advanced structure, facilitated expansion, coordinate stations’ work, could establish complex systems. ? Modularization industry-standard design, using DIN rail for mounting, easy to install on-site. ? Economic and reliable, powerful communication interfaces, available communication protocols with Modbus RTU/ASCII/TCP, DNP3 (optional) etc, have communication interfaces such as RS232, RS485, Ethernet etc. ? Efficient project development tools, conforming to the standard of IEC 61131-3, available programmable languages with LD, FBD, IL, ST, SFC. ? Friendly human-machine interface (HMI). ? Powerful hardware system, adopted 32-bit ARM processor, embedded multitasking real-time operating system (RTOS). ? Advanced redundancy/fault tolerance capability. ? Economic & efficient RTU system. ? -40 to +70 degrees C operating temperature range, 20 to 90%RH (non-condensing) operating humidity range, adapt for a wide range of rugged environments. ? Passed the CE certification and reached the EMC (level3) standard. ? Certificate of quality management system certification the QS9000. Application Field ? General industrial data acquisition and process control; ? Gas processing stations and gathering & processing stations in oil field ? Testing of process parameters and manufacture optimization control in oil field & oil well; ? Monitoring for gathering-transfer oil stations, oil depots, oil extraction and metering stations ? Gas lift wells control and natural gas flow calculation; ? Monitoring for hot-water boilers, industrial steam boilers; ? Remote control for water wells, pumping stations; ? Pipe leak detection, valve control and pipe flow measure; ? Open channels, sluices and water-level detection and control; ? Atmospheric environment and water quality monitoring; ? Telemetry and remote control for power system parameters; ? Water supply automation; ? Urban water treatment automation; ? Heating networks pipelines automation. Professional Environmental Monitoring Solutions 50 Development Tools Generally, the development tools of traditional RTUs were multiplex, because RTUs from different famous manufacturers have its independent system, incompatible each other, so the RTU’s developers and users must do a professional training so as to developing, using and maintenance RTUs. At that time, the investment of RTU projects’ established, the cost of operation and maintenance were expensive. With the software and hardware technologies development rapidly, this requires stronger and stronger that the RTU systems should adapt for different industrial situations and could exchange data, it’s the same for the RTU systems’ openness and compatibility. The development tool EOpen for Mapuni’s super E50 RTU systems is designed under the user’s demands, it adapts international standard the IEC61131-3, has perfect compatibility and openness. EOpen originates in OpenPCS system which got PLCOPEN international certification and designed by Germany enterprise INFOTEAM. Because of its perfect compatibility and openness, lots of investment cost would be saved during new system established and/or renovated works. EOpen use IL, LD, ST, SFC, FBD/CAC etc programming languages which meet the international standards, users and developmental engineers could choose one or several languages of them to flexible inter-use, so as to accomplish automation projects efficiently. Professional Environmental Monitoring Solutions 51 Features ? A system Configuration Software; ? Offline Simulation; ? Online Editor; ? Online Download; ? Convenience, rich Debugging Functions Laconic and Efficient MAPUNI HMI Software Platform MAPUNISCADA could be used in many projects area. Whatever your application site is, you could use MAPUNISCADA for effective supervision and data acquisition. MAPUNISCADA’S Functions ? Using clear and accurate pictures to describe industrial controls on-site; ? Using graphical push-button to realize single-task and multi-task; ? Design complex flashes to show the operation status and data in field; ? Display text and graphics information of production; ? Assignment of keyboard commands for any field image; ? Supervise and record all of the alarm information; ? Display real-time data curve and historical data curve; ? Flexible data search; ? Print date and event log; ? Scheme out Multi-level security control and access permissions; Professional Environmental Monitoring Solutions 52 Typical application case Description ? The figure of typical application case is a system architecture scheme of the end of gas-transfer station. ? HC501 is a main controller module, used for IO modules data acquisition and process. PC read the field data by network, then do analysis as display, alarm etc. ? HC301 is the extensional module for RS485 communication, it is used for connecting instruments to capture their data, such as the instruments like ultrasonic flow-meter and or gas components analyzer which provide COM interfaces in field. ? HC601 is flow calculation module of gas orifice, equivalent to a flow-meter. It calculates, accumulates the flow of gas orifice, and save the results of calculation by following a certain criteria. The results are ready to upload to PC and/or read by PC. ? The other modules in the system accomplish other control functions such as PID regulator, pressure acquisition, temperature acquisition, valve control and so on. Professional Environmental Monitoring Solutions 53 Specifications Name Description Power Supply for modules 5V±2@245mA Consumption 1.3W Communication Interfaces 2 Ethernet, 10Mbps RJ45 Interface RS232, DB9-Male;S232 / RS485, DB9-Male Hot standby Hot standby redundancy Clock / Calendar Hour/ Minute/Second/Year/Month/Day/Week I/O Module Capability Digital Input Quantity 512 Points Max Digital Output Quantity 512 Points Max Analog Input Quantity 256 Points Max Analog Output Quantity 128 Points Max Count Input Quantity 128 Points Max RTD Input Quantity 64 Points Max I/O Modules Quantity Maximum of 48 Analog Input Input Resistance 169O Signal Input Levels 0~20mA Resolution 16 bits Accuracy ±0.1%×full scale(25?); ±0.3%×full scale(entire temperature range) RTD Input RTD Type 100 ohm platinum (RT100) Scopes 80.30~175.8O Resolution 16 Accuracy ±0.3%×full scale (5?); ±0.6%×full scale (entire temperature range) Analog Output Signal Input Levels 4~20mA Resolution 16 bits Accuracy ±0.3%×full scale(25?); Professional Environmental Monitoring Solutions 54 ±0.5%×full scale(entire temperature range) Output Load <700O Digital Input ON Input Levels 8VDC (min.) ~ 26VDC(max) OFF Input Levels 3VDC (max) Current Input 5mA@24VDC Digital Output Output Load 250mA@24V Frequency 0~30Hz Pulse Input Signal Type Unipolar pulses Scopes Value 5—26 VDC Frequency 0~10 KHz Current Input >8mA Installation Inserted the second slot on the backplane, next to the power module, screw fixed Dimensions 118×43×92(mm) Professional Environmental Monitoring Solutions 55 Selection Guide Professional Environmental Monitoring Solutions 56 2.Remote Terminal Unit Super32-L RTU Overview Super32-L RTU is designed and produced according to the wide-temperature industry standard, and can adapt to different kinds of harsh and extreme industrial environment. It can be used in oil, gas, electrical, metallurgical, heat supply, boiler, atmosphere environment, hydrology, water supply, sewage treatment, street lamp monitoring, intellectual building etc. Super32-L RTU is a powerful RTU of Mapuni Technologies family of controllers, combines high-performance 32bit MCU, build-in Ethernet, and offers 3 serial ports (RS232/Rs485) optional. The product offers stronger storage and computing capacity, offers Modbus RTU, Modbus ASCII, Modbus TCP, DNP3 as native protocols. Additional, Super32-L RTU supports the 5 programming languages, and conforming to IEC61131-3 standard. Characters ? Working Temperature:-40~70?; Working Humidity: 5~95%RH, adaptable for various adverse environments. ? Adopts advanced 32-bit MCU, embedded real-time multi-task operating system (RTOS) ? Build-in an Ethernet port and 3 serial communication ports optional, such as RS232, RS485, supporting the communication modes of Ethernet, GPRS/CDMA/GSM, wireless radio, special line and satellite communications, etc. ? With 6M FLASH, 1M RAM and its particular 32K FRAM(Ferroelectric RAM) for use in saving large amount of configured parameters and history data long-term. ? Supports the 5 programming languages such as LD, FBD, IL, ST, SFC, and conforming to IEC61131-3 standard. ? Supports the communication protocols of Modbus RTU, Modbus ASCII, Modbus TCP, DNP3 (about to be on the market) and other custom protocols, convenient to connect with intelligent equipments of the third party. ? Perfectly driver and interface, supporting OPC, DDE, etc, convenient to fit with all configuration software to organize a network. ? Insulation protection is adopted for power source, signal I/O terminal, and is insulated from the main control circuit. ? Designed according to industrial standards with DIN guide rail structure, which is convenient for site installation and internal hardware configuration. ? CE Certification Professional Environmental Monitoring Solutions 57 3.Remote Terminal Unit Super E40 RTU Overview SuperE40 RTU is an advanced modular configuration RTU of Mapuni Technologies family of controllers, designed and produced according to the wide-temperature industry standard, and can adapt different kinds of harsh industrial environment, combines high performance 32-bit MCU, embedded RTOS. SuperE40 RTU adopts redundancy and Plug-and-Play techniques, support extension. Offers MODBUS RTU, MODBUS ASCII, MODBUS TCP, DNP3 as native protocols, supports all the current communication modes, offers 5 programming languages, and conforming to IEC61131-3 standard. The product is designed and produced according to the wide-temperature industry standard, and can adapt different kinds of harsh industrial environment. It can be widely used in oil, gas, delivery pipe, city gas, water supply, sewage disposal, heat supply, chemical industry, electric power, metallurgy, energy, building monitoring, boiler, etc. Characteristics ? With 32-bit MCU, 16-bit A/D and D/A, embedded RTOS. ? Working temperature - 40~70?, humidity 5~95%RH, adapted different kinds of harsh industrial environments. ? Offers rich and optional serial communication ports, such as RS232, RS485, Ethernet etc., supports the communication modes of telephone dial-up, Ethernet, GPRS/CDMA/GSM, wireless radio, special line and satellite communications, etc ? With 6M FLASH, 1M RAM and its particular 32K FRAM (ferroelectric RAM), capable of saving large amount of configured parameters and history data long-term. ? Supports the 5 programming languages (LD, FBD, IL, ST, SFC) and conforms to IEC61131-3 standard. ? Supports the communication protocols of MODBUS RTU, MODBUS ASCII, MODBUS TCP, DNP3 and other custom protocols, convenient to connect with intelligent equipments of the third party. ? Perfectly driver and interface, supporting OPC, DDE, etc, convenient to fit with all configuration software to organize a network. ? Industrial standard design, plug-pull structure, not only with rich I/O modules, but also modules of professional natural gas flow meter and PID optional. ? With modular redundancy configuration and Plug-and-Play techniques, high reliability system provided. ? Power supply, signal output and input units all adopting isolation protection, and isolated from the main circuit board. ? CE Certification Professional Environmental Monitoring Solutions 58 4.E6803 Data Collected Transporting System Overview E6803 Data Collector is a data collection and transmission device developed for environmental monitoring and regulation. It can monitor the situations of environment management and facility operations, and it also has the functions of data collection, storage and transmission to automatic environmental monitoring equipment. It can actively and passively receive orders, upload monitoring data, control equipment operation, feedback operation status and alarm information; it also features stable performance, convenient operation, highly-reliable design, a huge capacity of storage and redundancy communication design, and it is widely used in environmental protection, metallurgy, petrochemical industry, water conservation, various industrial fields and business. Quality ? Accorded with HJ477-2009 Standard. ? “5S” product management, quality control on whole processing; ? EMC testing, reached electrical product standard level-3 above; ? “Conformal Coating” testing, lightning protection, vibrate testing, software pressure testing; ? Temperature testing to reach standard at -10?~+60?; ? Stable ARM, embedded Linux system; Easy to maintain and operation ? Finished by touch screen Standard signal interface, well compatibility; ? Configuration display, Module design for vertical development; ? WEB inside, remote upgrading, operation and maintenance ? Value added service development, realize operation management on check on work attendance, statistics, performance evaluation, analysis and diagnosis. Service ? Professional R&D team, industrial process control, hardware and software design, industrial process control; ? Professional service team, included pre-sell support, customer after-service; ? Sophisticated spare part supply system for operation; ? Providing technical development service, OEM cooperation; Features ? 32 CPU of ARM9 MPU adopted by programmable controller, embedded Linux system; ? HJ/T212-2005 pollution resource transmission standard and Modbus protocol, main supplier and platform system transmission protocol, put into use after set up screen; ? 5 programming language of IEC61131-3sustainable for user second development, including LD ,FBD,SFC,IL and ST; ? 64M, 128M FLASH memorizer (extended to 2G), USB can derive historical data; ? 8-12 AI (4~20mA,1~5V,16 DPI), 8 DI(0~5V), 4 DO (AC250V1A touch spot signal), 5 Professional Environmental Monitoring Solutions 59 RS232 (or RS485),1 Ethernet interface; ? Communication module can be RS232/485, Ethernet or WIFI transmission module, GPRS/CDMA sustainable; ? One spot for transmission to meet the requirements of multi-platform data receiving; ? Video image composition on data acquisition; ? IE Explorer can be used for monitoring on-site data, parameter and working status; ? Working condition data acquisition, monitoring and management; ? Anti-interference, electromagnetic interference, lightning prevent; ? Data storage over 10 years, power break down protection; ? Watchdog function on hardware/software for ensuring system operation; Technical Parameter Name Specification CPU 32CPU, running speed 30MPIS, real time clock inside, integrated watchdog, 32 timer, 32 route PID RAM 64M Data Storage 128MFLASH, can be extended to 2G Data storage time after power off 10 years Average mean free error time 100,000h I/O Analog quantity input 8-12 Digital value input 8 Digital value output 4 Communication Professional Environmental Monitoring Solutions 60 RS-232 6 route Transmission type Full duplex, half-duplex Communication speed 300~115200bps Communication protocol HJ/T 212, Modbus RTU/ASC? Protocol mode Subject, subordinate Connection type DB-9P RS-485 2 route transmission type half-duplex Communication speed 300~57600bps Communication protocol HJ/T 212, Modbus RTU/ASCII Protocol mode Subject, subordinate Connection type binding post Ethernet 1 route Way of transmission Full duplex Communication speed 10~100Mbit/s Communication protocol HJ/T 212,Modbus TCP/IP Connection RJ45 Summary Analog quantity input 0/4~20mA,1~5V Digital value input 0~5V electrical level signal Digital value output Touch spot signal A/D resolution ratio 16 Operation mode local or remote Way of power supply 220VAC,backup battery (optional) Power time of back-up source 10 hours Power consumption 15W (minimum) Size cabinet: (W×H×D) 430mm×175mm×450mm wall-mounted: (W×H×D) 280mm×350mm×100mm Professional Environmental Monitoring Solutions 61 Working Temp. -10~+60? Humidity 5~95%RH Storage Temp. -50~85? Professional Environmental Monitoring Solutions 62 Chapter 5 Emergency Monitoring 1. YT3G-4112DB1(DUAL CARD SPLIT) 3G VIDEO MONITORING SYSTEM Overview This is specially designed for emergency communication outdoors, which combined all kinds of latest technology in IT field with embedded processor and embedded operating system, like AV compress/uncompress, high-capacity HDD record, TCP/IP and so on, along with special technology of quakeproof and antiriot, specific HDD protection technology, which effectively resolved waterproof, portable, power supply outdoors and other problems. Features ? Embedded model design, hardware dog internally installed, ensuring stable running of system, and support video, data business, AV synchronization and two way voice communications; ? 2cards 3G WIFI network transmission, choosing WCDMA, CDMA200 or TDSCDMA of China Mobile as you like, support the transmission mode of broadband satellite, maritime satellite and other based on RJ45 network interface; ? Super-strong, high-efficiency NMVS-UH.264 coding, bandwidth adaptive and unique pretreatment technology, focus on visual details, ensuring high quality image (352×288 or 704×576) and video (supreme can be 25 frame/s); ? EVDO,WCDMA,TDSCDMA CDMA1x WIFI compatible; ? Unique reliable interconnection technique to ensure video smooth transmission under bad network condition based on 3G wireless network; ? Support various PTZ protocol, expandable; ? Support local HDD, centre computer server, client-side recording; ? Super-iron battery or lithium battery; ? Small-sized, light-weighted, be portable; Technical Parameters Mode E411xB2 Main CPU Hi3512 System 4 routes record and replay at same Video PAL,NTSC Professional Environmental Monitoring Solutions 63 Resource time, multi-routs network transmission standard Audio Compress H.264 Audio compress ADPCM Type of Recorders Manual, timing, alarm, mobile surveillance, order trigger Recorders inquiry Time retrieval, fact retrieval, channel retrieval Way of Backups Internet backup, USB backup Video input 4 route BNC(1-4 route aviation head for option) Audio Input 2 route BNC Video output 1 route BNC Audio Output 1 route BNC Video quality PAL:352×288(CIF) NTSC:352*240(CIF) Replay Quality PAL: 352x288(CIF) NTSC:352x240(CIF) Video control 6 grades adjustable Removable Detection 396(22×18) surveyed area can be set up, multi-level sensitivity as well Screen display Single picture four pictures Recorder Speed PAL:25frames/sec(adjustable) NTSC:30frames/sec (adjustable) record storage HDD,SD Card, network Local Replay 1 route,4 route replay Alarm input 4 switching value Alarm Output 1 relay output Cradle head control RS485 Memory Interface 2 SATA Network port Ether network interfaceRJ4510M/100M Network Protocol TCP/IP,UDP,HTTP,RTP USB 1 USB2.0 high speed port,1 USB1.1port Power DC 12V Charging source AC 220V The hardware equipment designed as two portable cases, details as followed: Chart 1 dual card split 3G video monitoring terminal hardware configuration-portable host computer configuration table Type List 3G removable emergent cases (video capturing and transferring) Audio Talkback Route 1 input, handset microphone, route 1 audio output, sound box inside. Communication Formwork Bi-module 3G;3G sustainable; double card vertical inserted; works well after box closed; one communication module from CDMA2000, WCDMA, TD-SCDM; transmission mode of Martine satellite BGAN sustainable; pop-up Professional Environmental Monitoring Solutions 64 Type List 3G removable emergent cases (video capturing and transferring) UIM(SIM)cassette. Antenna 3 high gain antennas, outer part of cases needs to do waterproofing Display Screen 10 inch LCD output can realize cloud deck operation, video and equipment parameters configuration. GPS Positioning 1 high quality GPS module. Positional info should be connected to Mapuni platform. Storage 1 2.5"SATA HDD,320GB notebook HDD continuous storage, automatic segmentation, record on segmentation of levels, recording new file according to recording time after fully saved with the way of cycling and covering, support the partition and formatting on HDD. Working Panel 2 pop-up UIM(SIM)card;1 route RS-232 ,1 route RS-422;2 ? USB2.0 1 ?USB1.1 data backup, mouse action, software intelligent upgrading and so on(1 USB port needs to drive transmission line at least 5 meters, used for off board card back up) control keyboard;1 route 10/100M Ethernet (RJ45), can connect with marine satellite BGAN or other networks, wireless internet sustainable. Device Interface 4 route input; 1 route audio input; 1 route audio output; 3 antenna Interface; outer device interface of case needs to do waterproofing . Portable Device Black suitcase, storage temp.-40?~85?,electric damping and machinery damping, all interfaces can be anti-static electricity; IP65; waterproof, anti-pressure, wrestling prevent; size:403(length)×330(width)×175(height)(mm)or 428(length)×361(width)×192(height)(mm) Inner Framework and Cable High quality, orderliness of inner line, welding spot protection, proper layout of interface bottom of board, fully consider the internal storage space, low temperature resistant cable; antifreeze, preservative fluid. Software Function Debugging wired and wireless; network parameter settings; multi-screen pictures; recording; alarming; upgrading on line; multi-route video monitoring; The network of different operator in different districts can be suitable, debugged for completion. Chart 2 Dual card split 3G the power supply of terminal hardware configuration of video monitoring and its accessory cases configuration Type List 3G removable emergent cases(Power supply and accessories) Camera and Holder 1 small hemisphere, waterproof holder camera with sucker, SONY480 movement, 10~20 zoom, remote control( cloud deck), interface cannot be placed inside box; 1 light tripod, can rise 1.5 meters above( with iron pan) Recharger 1 advance recharger, reduced the charging time to 8~12 hours, be set in the case. Professional Environmental Monitoring Solutions 65 Type List 3G removable emergent cases(Power supply and accessories) Power Battery High quality lithium battery of war industry or iron phosphate lithium battery, usage time in outdoors will be 6~8 hours, working along with recharging at the same time can be realized, power supply mode is AC and vehicle-mounted. Working Panel High quality lithium battery of war industry (20Ah) iron phosphate lithium battery(15Ah);power light; charging interface. Outer device ports needs to do waterproofing. Device Interface External power source interface Portable Device Black suitcase, storage temp.-40? ~ 85?,electric damping and machinery damping, all interfaces can be anti-static electricity; IP65; waterproof, anti-pressure, wrestling prevent; size:403(length)×330(width)×175(height)(mm)or 428(length)×361(width)×192(height)(mm) Inner Framework and wire cable High quality, orderliness of inner line, welding spot protection, proper layout of interface bottom of board, fully consider the internal storage space, low temperature resistant cable; antifreeze, preservative fluid. Accessories CD including installation system and instruction manual,1 net wire, remote control unit,3G antenna(2),GPS antenna, OEM Application Field Be appropriate for emergency defend, mobile monitoring, vehicle-mounted recharging during mobile command, such as environmental emergency, on-site investigation in environmental accident, monitoring on mobile risk source, emergency rescue, remote check and accept and diagnosis, people’s armed police and so on. Professional Environmental Monitoring Solutions 66 2 YT3G-4112DB1(DUAL CARD SPLIT) 3G Video Monitoring System Overview This is specially designed for emergency communication outdoors, which combined all kinds of latest technology in IT field with embedded processor and embedded operating system, like AV compress/uncompress, high-capacity HDD record, TCP/IP and so on, along with special technology of quakeproof and antiriot, specific HDD protection technology, which effectively resolved waterproof, portable, power supply outdoors and other problems. Features ? Embedded model design, hardware dog internally installed, ensuring stable running of system, and support video, data business, AV synchronization and two way voice communications; ? 2cards 3G WIFI network transmission, choosing CDMA200, WCDMA or TDSCDMA of China Mobile, support the transmission mode of broadband satellite, maritime satellite and other based on RJ45 network interface; ? Super-strong, high-efficiency NMVS-UH.264 coding, bandwidth adaptive and unique pretreatment technology, focus on visual details, ensuring high quality image(352×288 or 704×576)and video(supreme can be 25 frame/s); ? EVDO, WCDMA, TDSCDMA CDMA1x WIFI compatible. ? unique reliable interconnection technique to ensure video smooth transmission under bad network condition based on 3G wireless network; ? Support various PTZ protocol, expandable; ? Support local HDD, centre computer server, client-side recording; ? Super-iron battery or lithium battery; ? Small-sized, light-weighted, be portable; Technical Parameters Mode E411xB2 Main CPU Hi3512 System Resource 4 routes record and replay at same time, multi-routs network transmission Video standard PAL,NTSC Audio Compress H.264 Audio compress ADPCM Type of Recorders Manual, timing, alarm, mobile surveillance, order trigger Recorders inquiry Time retrieval, fact retrieval, channel retrieval Professional Environmental Monitoring Solutions 67 Way of Backups Internet backup, USB backup Video input 4 route BNC(1-4 route aviation head for option) Audio Input 2 routes BNC Video output 1 route BNC Audio Output 1 route BNC head Monitoring quality PAL:352×288(CIF)NTSC:352*240(CIF) Replay Quality PAL:352x288(CIF) NTSC:352x240(CIF) Image control 6 grades adjustable Removable Detection 396(22×18) surveyed area can be set up, multi-level sensitivity as well Screen display Single picture four pictures Recorder Speed PAL:25frames/sec(adjustable)NTSC:30frames/sec (adjustable) Recorder storage HDD,SD card, network Native Replay 1 route,4 route replay Alarm input 4 switching value Alarm Output 1 relay output Cradle head control RS485 Memory Interface 2 SATA Network Ether network interface RJ45 10M/100M Network Protocol TCP/IP,UDP,HTTP,RTP USB 1 USB2.0 high speed connector 1 USB1.1 Power DC 12V Recharging source AC 220V Chart 1 dual card in one 3G video monitoring terminal hardware configuration Property Parameter Type 3G mobile communication terminal on acquisition of law enforcement Camera and Holder Video image clear, no vibration. 1 small hemisphere, waterproof holder camera with sucker, remote control( cloud deck), 1 light tripod, can rise 1.5 meters above Camera Features SONY480movements 10~20 zoom, CCD type:1/3 Pixel::PAL:752H×582V NTSC: 768H×494V Signal system: PAL/NTSC Resolution ratio: 520TVL Minimum illuminance:0Lux(infrared ray opened) Signal-to-noise ratio:= 48dB Audio Talkback Clear, no noise. 1 route input, handset microphone, 1 route audio output, voice box inside. Communication Model Bi-module 3G;3G network sustainable; works well after box closed; one communication module from EVDO(CDMA2000), WCDMA of China Unicom; transmission mode of Martine satellite BGAN sustainable; pop-up UIM(SIM)cassette. Transmission Dual mode 3G transmission, CIF 20 fps, average delay 3-5 sec, single card reached 3 fps at lowest, average delay20-40 sec; frame rate:1~25 fps adjustable Antenna 3 high gain antennas, outer part of cases needs to do waterproofing Display 12 inch LCD output can realize cloud deck operation, video and equipment Professional Environmental Monitoring Solutions 68 Property Parameter parameters configuration. GPS Positioning 1 high quality GPS module, 12 parallel channels, and tracking 12 satellites Charger 1 advance recharger, be set in the case. Power/Battery Supply Power supply module inside, high quality lithium battery of war industry or iron phosphate lithium battery, usage time in outdoors will be 6~8 hours, working along with recharging at the same time can be realized, power supply mode is AC and vehicle-mounted. Storage 1 2.5"SATA HDD,1T notebook HDD continuous storage, automatic segmentation, record on segmentation of levels, recording new file according to recording time after fully saved with the way of cycling and covering, support the partition and formatting on HDD. Panel and Device Interface 4 route input(1Vpp,75O,BNC interface PAL/NTSC),1 route video output;1 route audio input, 1 route audio output; 2 pop-up UIM(SIM)card; 3 antenna interface ;1 route RS-232 ,1 route RS-422,1 route loop connection of electricity;4 USB2.0 1 USB1.1 data backup, mouse action, software intelligent upgrading;1 infrared ray, remote control operation; High quality lithium battery of war industry(20Ah)or iron phosphate lithium battery(15Ah);1 route 10/100M Ethernet (RJ45),can connect with marine satellite BGAN or other networks, wireless internet sustainable. Outer device ports needs to do waterproofing. Portable Device Black suitcase, storage temp.-40?~85?,electric damping and machinery damping, all interfaces can be anti-static electricity; IP65; waterproof, anti-pressure, wrestling prevent; size: 492(length) ×395(width)×216(height)(mm) Interior Framework and Cables High quality, orderliness of inner line, welding spot protection, proper layout of interface bottom of board, fully consider the internal storage space, low temperature resistant cable; antifreeze, preservative fluid. Software Debugging wired and wireless; network parameter settings; multi-screen pictures; recording; alarming; upgrading on line; multi-route video monitoring; The network of different operator in different districts can be suitable, debugged for completion. Accessories CD including installation system and instruction manual,1 net wire, remote control unit,3G antenna, GPS antenna Application Field Be appropriate for emergency defend, mobile monitoring, vehicle-mounted recharging during mobile command, such as environmental emergency, on-site investigation in environmental accident, monitoring on mobile risk source, emergency rescue, remote check and accept and diagnosis, people’s armed police and so on. Professional Environmental Monitoring Solutions 69 Chapter 6 Unmanned Aerial Vehicle 1. Uni-Eagle2 Mapuni Aerial Survey Fixed Wing UAV Advantages Aerial survey-type UAV is a regular aerodynamic configuration vehicle, which is characterized by flight attitude stability, high working efficiency, suitable for orthophoto data acquisition. Technical Parameters No. Name Technical Parameters 1 Wingspan/Length 2.6m/2.1m 2 Maximum taking off weight/Task Loading 20kg/5kg 3 Max cruise time 2.5h 4 Max range 300km 5 Cruising speed 120km/h 6 Anti-wind capability 5level 7 Max ceiling 6000m 8 Control mode Remote manual control(RC) ? automatic control(UAV) 9 Taking off& landing mode Taxiing landing/launching parachute downward 10 Working temperature -20-50 degrees Name Sub-system Name System Configuration Unit QTY UAV System Body Fiberglass body, Japanese braking systems, fuel tanks, H645 rudder actuator, 10C remote control equipment, parachute and so on. Set 2 Auto Pilot On-board flight control box, terrestrial observing notebook suit, Omni-directional digital antenna, digital radio, ground Set 1 Professional Environmental Monitoring Solutions 70 station software systems etc. Digital Camera CANON 5Dmark?fuselage, each of 24mm&35mm lens, battery, recharger, control line, memory card, card reader, camera calibration parameters etc. Set 1 Accessories Starter, battery, charger, special tools, mechanical and electronic parts, Toolbox etc. Set 1 Successful Case ? Environmental Emergency Provides a complete UAV contingency solution Aerial (customizable multi-type sensors) + data processing + data processing application products + services Emergency Vehicle ? Disaster Monitoring Environmental disaster monitoring use of various techniques and methods, measurements, monitoring activities, as well as a variety of dynamic changes of induced factors of geological hazards. It is the important basis for forecasting geological hazards, and therefore it is an important content of the disaster. 2. Uni-Eagle Z15 Mapuni Unmanned Aerial Helicopter Advantages Professional Environmental Monitoring Solutions 71 Advantages of payload capacity, portable HD cameras, flying at low altitude, quickly capturing the target point of the image or video, or mounting pollution detection device. Technical Parameters No. Name Technical Parameters 1 Task load weight 20kg 2 Main diameter 3.2m 3 Tail rotor diameter 0.55m 4 Length 3.6m(Including the rotor) 5 Fuselage length 2.7m 6 Max Fuselage width 1.1m 7 Cruise time Less than 1h(20kg task loading) 8 Cruise time Over2 hours(10kgTask loading) 9 Max cruising speed 120km/h 10 Control radius Less than 30km 11 Ceiling Reach over 3000m Name Sub-system Name System Configuration Unit QTY Unmanned Helicopter System Body Carbon fiber body, Japanese braking systems, fuel tanks, Thunder Tiger servos implementing agencies, 12C remote control device, such as pan/tilt PTZ controller, device etc. Set 1 Auto Pilot On-board flight control box, terrestrial observing notebook suit, Omni-directional digital antennas, Panel video, real time image transmission receiving antenna receiving systems, video monitors, digital radio, ground station software systems. Set 1 Digital Camera & Vedio CANON 5Dmark?fuselage,18-300 lens, Sony camera, battery, charger, the Set 1 Professional Environmental Monitoring Solutions 72 control line, memory cards, card readers, camera calibration parameters. Accessories Starter, battery, charger, special tools, mechanical and electronic parts, toolbox etc. Set 1 Successful Cases ? Environmental Emergency Environmental emergency UAV system which is based on the unmanned helicopter, designing for environmental emergency response set of video, aerial, toxic and hazardous gas monitoring, weather data monitoring, auxiliary decision-making function all in one environmental emergency monitoring& management system. The system adopts modular design concept, according to the tasks need to be equipped with a wide range of environmental monitoring instrument, enabling the various emergency monitoring of toxic gases. The environmental emergency command center can analysis various types of data from the transmitted site date, which will provide scientific basis for the leaders in the emergency incidents. ? Disaster Monitoring Environmental disaster monitoring use of various techniques and methods, measurements, monitoring activities, as well as a variety of dynamic changes of induced factors of geological hazards. It is the important basis for forecasting geological hazards, and therefore it is an important content of the disaster. Professional Environmental Monitoring Solutions 73 Chapter 7 Radiation Monitoring 1. RAYGUARD ??? Personal Radiation Monitor Overview High sensitivity radiation detecting and data handling with bulk mass GM tube radiation monitor, speed load data which fluctuate slightly, which simultaneous measuring dose rate and accumulated dose, alarming with sound, light and vibration. Users can set up alarm threshold value of radiation dose themselves based on their requirements. Features: ? Bulk mass GM tube monitor, the sensitivity of measuring environmental background is high; ? Simultaneous display dose equivalent rate and accumulated dose; ? Alarming when dose equivalent rate and accumulated dose over-ranged; ? Display alarm threshold value and type; ? Two AA dry battery for power supply, displaying dump energy ? CLK, data storage after shut down, clock runs as usual; ? USB, easy to connect with computer, equipped with personal dose management software. Technical Parameters Detector GM counter tube Response 48keV~1.5MeV=±25%(relative to 137Cs) Measuring range Dose equivalent rate: environmental background~600µsv/h Dose equivalent: 0~9999mSv Measuring time Updating every 2 seconds display modes LCD, dose equivalent rate(µsv/h) and dose equivalent (µsv) relative error dose equivalent rate =±20%; dose equivalent =±15% Safeguard alarm time =5 sec(dose equivalent rate=15µSv/h) Professional Environmental Monitoring Solutions 74 Power consumption <3.5mW Dimension 116(H) ×60 (W) ×22(D) mm Weight 90g Application Field Radiation dose monitoring and alarm for the staff working in power station, bureau of environmental protection, entry-exit inspection and quarantine bureau, customs; Radiation dose monitoring and alarm for the staff working in irradiation factory, thickness gauge, nondestructive inspection, level gage and others; Radiation dose monitoring and alarm for the staff engaging in radioactivity treatment, nuclear technology application and others. 2. RAYGUARD Food and Water Nuclear Radiation Monitor Overview RAYGUARD Food and Water Radiation Monitor is used for measuring the specific activity of Cs-137,I-131 radioisotope in the food, water( all beverage included). This is equipped with scintillating crystal detector, high-sensibility, quick-response, easy to use, LCD menu display. AC 85~240V adopted, set up two dry battery for emergency power supply at different occasions. Features Measuring gamma, alpha and beta ray High sensitive Professional Environmental Monitoring Solutions 75 Technical Parameters Detector Ø30×25mm NaI(Tl)scintillating crystal valid measuring range 10~10000Bq/L(Bq/Kg) relative inherent error =20% lead wall thickness 12mm LCD display Cs-137&I-131 specific activity LED indicator light “green”, “yellow”, “red”, respectively express “safe” “slight” “over-proof” working temperature 0~40? working humidity =80%RH (40?) Main power supply AC 85-240V,50-60Hz emergency power supply AA(No.5)two battery Power consumption <200 mW Dimension 180×170×295mm(length × width × height) Weight 13Kg Application Field Widely apply to family, marketplace, company and all institutions on disease control, environmental protection, inspection and quarantine to quick check radioactive contamination level on water or food. 3. BS9511 High Precision Nuclear Radiation Detector Overview BS9511 is a detector to radiation absorbed doses, human oriented design, easy to carry and use, which adopting scintillated detector of high sensitivity and accuracy with rapid response. It is ideal product for radiation monitoring, and it fully accord with environmental monitoring of absorbed dose rate of relevant national standard. Be used in various bad circumstances and outdoors with huge LCD screen, and background light, more than 1000groups of 64K storage data. Technical Parameters Detector f30×25mm,NaI(TL) Sensitivity =350CPS Energy range 48keV~3MeV Energy valve 35keV Energy Response =±20%(relative to 137Cs) Measuring range Dose equivalent rate: 0.01~600µGy/h Dose equivalent : 0~9999mGy Comparative basic discprepancy =±10% Repeatability =5%(1µGy/h) Professional Environmental Monitoring Solutions 76 Alarm item Super threshold overload, fault, battery under voltage Type of alarm Sound Temp. range -20?~50? Relative humidity range =90% (40?) Power consuming 160mW battery Power supplier 2 batteries of No.5 Material: Aluminium Alloy Dimension 24.3×8.9×14.2(cm) Weight 1.5Kg Characteristics Use LCD screen, background light and shows clearly. High sensitivity & accuracy, also having good energy response characteristic. Dose ratio alerting threshold can be set. 64K storage, more than 1000 groups can be stored. Dose ratio, accumulated dose can be measured. With super dose ratio threshold, over loading, accident, less battery voltage alerting function. Aluminum alloy case, small and convenient, suitable for outdoor operation. Application Field Meet the needs of environmental protection, health, metallurgy, petroleum, chemical industry, commodity inspection and other sectors of the radiation protection monitoring requirements. 4. BS9521 X, Y Ray Radiation Dose Meter Overview BS9521 is a dose equivalent rate detector of radiation protection at all kinds of places of radiation, which enjoy more sensitivity compare to ionization chamber detector with scintillation detector of high efficiency, and it fully accord with environmental monitoring of absorbed dose rate of relevant national standard. BS9521 X, Y Ray Radiation Dose Meter Professional Environmental Monitoring Solutions 77 Technical Parameters Detector NaI(Tl) Energy range 35keV~3MeV Energy valve 35keV Energy response =±20%(relative to137Cs) Measuring range Dose equivalent rate:0.01~2500 Sv/h Dose equivalent : 0~9999mSv Proportional error =±10% Repeatability =5%(1 Sv/h) Alarm item Super threshold overload, fault, battery under voltage Type of alarm Sound Material: Aluminium Alloy Dimension 24.3×8.9×14.2(cm) Weight 1.75Kg Characteristics ? To use LCD screen, background light and shows clearly. ? High sensitivity& accuracy, good energy response characteristic. ? Dose ratio alerting threshold can be set. ? 64K storage, more than 1000 groups can be stored. ? Dose ratio, accumulated dose can be measured. ? With super dose ratio threshold, over loading, accident, less battery voltage alerting function. ? Aluminum alloy case, small and convenient, suitable for outdoor operation. Application Field Mainly used for safety of sanitation, environment protection, injury detecting, metallurgy, oil, chemical industry and radioactive lab, radiation source management, commercial inspection, in-out abroad, airport and those high people density places Which can be used in various bad circumstances and outdoors. Professional Environmental Monitoring Solutions 78 5. BL2015 Scintillation Chamber Radon Measuring Instrument Overview BL2015 with large size of photomultiplier tube (PMT) and replaceable flash type sampling barrel, equipped air sampling pump and a rechargeable battery which can be continuous air sampling and measurement. It used 32 bit embedded ARM processor as a data processing unit, displaying with large screen, easy to use. Measured data can be preserved on the long term basis, and be downloaded to a computer for data analysis. Technical Parameters Detector ZnS scintillated detector Measuring target: Rn-222?radon?;Rn-220?thoron? Measuring range: 10~5×107Bq/m3 Sensitivity about6 CPS/Bq/m3 to Rn-222 Sample count cycle: Customized definition Sampler: ZnS doliform Sampler specification 110ml(F51.8mm×52mm), 372ml(F51.8mm×128mm) Operation & Display: LCD display in Chinese, operation with menu Type of battery: lithium battery, 36 hours( without pump) or 18 hours( with pump) Charging time: 5 hours Low power indicator: Battery voltage display, alarm when under voltage Data storage: 999gourps data( 1 group data every hour records 42 days data) Data download: Data download to computer for analyzing(with emano-meter data handling software) Printer: Can be connected mini-printer for printing measuring data. Pump flow of sampling: 2litre/mins Temp. range -5?~50? Relative humidity range 0~99%,no frozen Power supplier 220v Dimension 28.5×20.5×26.5(cm) Weight 3Kg Professional Environmental Monitoring Solutions 79 BL2015 SCINTILLATION CHAMBER RADON MEASURING INSTRUMENT Application Field Widely apply to environmental protection, seismologic surveillance, construction works, mining, universities and other research institutions. 6. Home Formaldehyde Monitor BGFM-06 Overview BGFM-06 is the first formaldehyde detector in China, independent R&D by Begood Technology Ltd.,Co. This product converts the formaldehyde concentration signal in the air to electrical signal with leading technology of electrochemistry sensor and high-accuracy chip information, displaying in digital LCD after microcomputer handling, non-stop monitoring to protect your family. Features ? Imported electrochemical sensor, ? Precisely response the formaldehyde concentration ? LCD digital display with large screen ? Early warning system at three levels with intelligent notice of backlight, alarm and facials ? Temperature and humidity monitoring ? Temperature self-service converter ? Low power consumption, rechargeable battery ? Invest at one time far from formaldehyde ? Scope of Application: home, office, automobile ? EU standard and CE-approval Professional Environmental Monitoring Solutions 80 Technical Parameters Model BGFM-06 Display LCD digital display Measuring Way Electrochemical sensing technology Measuring Range 0 ~ 5 ppm Precision 10% Resolution 0.01ppm or 0.01 mg/m3 Atmospheric Pressure 1 atm Temp. Range +5~+60°C Relative Humidity Range 20~90%RH Power Supplier 3.6v (Built-in 3 NiMH rechargeable batteries) Dimension 150mm ×90mm ×40mm Net Weight 0.56Kg Total Weight 0.74Kg Application Field Homes offices& cars. 7. BS9611 Nuclear Radiation Personal Dose Alerting Meter Overview Masure & alert for radiation personal dose. Easy to operate, low cost but high reliability, accuracy. BS9611 is for low a, ß radiation surface contamination detection. Dual-flash detector apparatus with high detection efficiency; the same probe can simultaneously measure a, ß, and automatically Professional Environmental Monitoring Solutions 81 distinguish between a and ß particles. Technical Parameters Detector Double flash detector Detector Area 19.6 cm² Counting Range 1~106 Detection Efficiency a = 30% (of 239Pu), ß = 30% Sensitivity Surface activity of a response> 7s-1Bq-1cm2 Surface activity of ß response> 7s-1Bq-1cm2 Measurement Floor Counts per minute a = 3, ß = 120 Measuring Time 1,10,20,60,120 seconds optional Display Units CPM, CPS, Bq/cm2 Relative Basic Error = ± 20% Temp. Range -10?~45? Relative Humidity Range =90%(40?) Power Supplier 2 batteries of No.5 Material engineering Alloy Dimension Operator:150×200×90(mm) Total Weight 1.20Kg Detector Double flash detector Application Field Environmental laboratory, nuclear medicine, molecular biology, radiation chemistry, nuclear materials transport, storage and inspection areas such as a, ß radiation ideal surface contamination detection instrument, which uses single chip control, continuous data collection, storage. 8. BSRPM-9030-1 Channel-type Vehicle Radioactive Automatic Monitor System Overview BSRPM-9030-1 channel-type vehicle radioactive automatic monitor system is the radioactive automatic monitor system which configures large-volume, high-sensitivity gamma-ray detector. It can real-time detect the passing through vehicle, find traces of the radioactive materials, output the alarm and store the test data. The system can also network with the upper management systems at the same time, which will constitute a remote real-time detection information system. The systems are widely used in some places’ entrances, exits or channels, such as the frontier& ports to detect the vehicles& containers whether taking the radioactive materials. Professional Environmental Monitoring Solutions 82 Technical Parameters ? Detector: 4 plastic scintillators+ double low-noise photomultiplier tubes, a single crystal sensitive with the volume of 30 liters. With 3mm lead (5 faces) which will screen the interference of the background, and every detector weighs about 150kg (detector+ dos shell); ? Detection of ?-rays and x-ray, energy range of 25keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Monitoring area coverage: height=5m;width=6m; (BSRPM-9030-1 series) ? Alarm: Sound alarm& light alarm (the alarm can distinguish the alarms between radiation and over-speed), adjustable of the alarm thresholds, which can be connected to a remote management computer with a special back-management software; ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the traffic, the alarm data, capture images, automatically print the reports& network with the upper management. ? Working environmental conditions Temperature: -30?~+50?; Humidity: Less than 95% (No condensation); ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A); ? Installation category II (voltage level should follow the provisions of IEC1010-1). Application Field Ports, terminals, scrap metal transportation bases, air ports, Customs and so on. 9. BSRPM-9030-2Channel-type Vehicle Radioactive Automatic Monitor System Overview BSRPM-9030-2 channel-type vehicle radioactive automatic monitor system is the radioactive automatic monitor system which configures two large-volume, high-sensitivity gamma-ray detectors. It can real-time detect the passing through vehicles, find traces of the radioactive materials, output the alarm and store the test data. The system can also network with the upper management systems at the same time, which will constitute a remote real-time detection information system. The systems are widely used in some places’ entrances, exits& channels, such as Customs, ports, even some metal recovery and smelting enterprises use the system to detect the small/medium trucks& cargo to see whether taking the radioactive materials. Professional Environmental Monitoring Solutions 83 Technical Parameters ? Detector: 2 plastic scintillators (1200mm*500mm*50mm) + double low-noise photomultiplier tubes, a single crystal sensitive with the volume of 30 liters. With 3mm lead (5 faces) which will screen the interference of the background, and every detector weighs about 150kg (detector+ dos shell); ? Detection of ?-rays and x-ray, energy range of 25keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Monitoring area coverage: height =4m; width=5m;(BSRPM-9030-2 series); ? Alarm: Sound alarm& light alarm (the alarm can distinguish the alarms between radiation and over-speed), adjustable of the alarm thresholds, the alarm can be connected to a remote management computer with a special back-management software; ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the traffic, the alarm data, capture images, automatically print the reports& network with the upper management. ? Work environment: Temperature: -20?~+50?; Humidity: Less than 95% (No condensation); ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A); ? Installation category II (voltage level should follow the provisions of IEC1010-1). Application Field Ports, terminals, scrap metal transportation bases, air ports, Customs and so on. 10. BSRPM-9030-3 Channel-type Pedestrian Radioactive Automatic Monitor System Overview BSRPM-9030-3 channel-type pedestrian radioactive automatic monitor system is the radioactive automatic monitor system which configures large-volume, high-sensitivity gamma-ray detector. It can real-time detect the passing through pedestrian, find traces of the radioactive materials, output the alarm and store the test data. The system can also network with the upper management systems at the same time, which will constitute a remote real-time detection information system. The systems are widely used in some sites’ entrances, exits, such as airports, terminals and so on, to detect whether the pedestrian or luggage whether taking the radioactive materials. Professional Environmental Monitoring Solutions 84 Features ? Embedded with computer processing system will have great extension capacity; ? With LCD directly displays the status; ? Easy to set the alarm threshold; ? According to the site the detector can be flexibly configured; ? Adopt fieldbus transmission mode, cable transmission distance can up to 1 km (wireless transmission distance can up to 10 km); ? For the abnormal state (super-threshold, overload& failure), the system will warn and timely store the data for the operator to monitor at any time; ? it can communicate with the computer by the serial port or network port. Technical Parameters ? Detector: 2 plastic scintillators(1200mm*250mm*50mm)+ double low-noise photomultiplier tubes, a single crystal sensitive with the volume of 15 liters. With 3mm lead (5 faces) which will screen the interference of the background; ? Detection of ?-rays and x-ray, energy range of 25keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Monitoring area coverage: height=2m;width=1.8m; (BSRPM-9030-3 series) ? Alarm: Sound alarm& light alarm, adjustable of the alarm thresholds, the alarm can be connected to a remote management computer with special back-management software; ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the transit, the alarming data, capture images, automatically printing the reports& network with the upper management. ? Work environment: Temperature: -10?~+50?; Humidity: Less than 95% (No condensation); ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A); ? Installation category II (voltage level should follow the provisions of IEC1010-1) 11. BSRPM-9030-4 Channel-type Luggage Radioactive Automatic Monitor System Features ? With dynamic calibration and auto calibration which can real-time monitor and detect the possible target radiation (radioactive material); ? The system use one set large-scale plastic scintillator detector, (600mm*500mm*50mm, 15 liters). The detector installed under the conveyor belt which is very closer to the conveyor belt; ? Every detector is equipped with dual photomultiplier for the signal processing, which can greatly reduce interference and improve the detection efficiency of 30%; Professional Environmental Monitoring Solutions 85 ? The system uses infrared detector detects the passing through packages, which can effectively distinguish the system is in the update mode or detection mode; ? The system management computer software has English operation, friendly interface, according to the test site workers’ actual operation processes, providing easy, convenient, comprehensive operation. Technical Parameters ? Detector: one plastic scintillator (600mm*500mm*50mm) + double low-noise photomultiplier tubes, a single crystal sensitive with the volume of 15 liters. With 3mm lead (5 faces) which will screen the interference of the background; ? Detection of ?-rays and x-ray, energy range of 25keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Passageway dimension: 1300mm (height) X 1500mm (width); ? Alarm: Sound alarm& light alarm, adjustable of the alarm thresholds, the alarm can be connected to a remote management computer with a special back-management software; ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the transit, the alarm data, capture images, automatically print the reports& network with the upper management; ? Work environment: Temperature: -30?~+50?; Humidity: Less than 95% (No condensation); ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A); ? Installation category II (voltage level should follow the provisions of IEC1010-1). 12. BSRPM-9030-5 Channel-type Vehicle&Train Radioactive Automatic Monitor System Overview BSRPM-9030-5 channel-type vehicle/train radioactive automatic monitor system is the radioactive automatic monitor system which configures two large-volume, high-sensitivity gamma-ray detectors. It can real-time detect the passing through vehicle/train, find traces of the radioactive materials, output the alarm and store the test data. The system can also network with the upper management systems at the same time, which will constitute a remote real-time detection information system. The systems are widely used in some places’ entrances, exits& channels, such as Customs, ports, even some metal recovery and smelting enterprises use the Professional Environmental Monitoring Solutions 86 system to detect the small/medium trucks& cargo whether taking the radioactive materials. Technical Parameters: ? Detector: 4 plastic scintillators(1200mm*500mm*84mm)+ double low-noise photomultiplier tubes, one single crystal sensitive with the volume of 50 liters. With 3mm lead (5 faces) which will screen the interference of the background, and every detector weighs about 250kg (detector+ dos shell); ? Detection of ?-rays and x-ray, energy range of 20keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Monitoring area coverage: height=6.5m; width=6m; (BSRPM-9030-5 series); ? Alarm: Sound alarm& light alarm (the alarm can distinguish the alarms between radiation and over-speed), adjustable of the alarm thresholds, the alarm can be connected to a remote management computer with a special back-management software; ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the traffic, the alarm data, capture images, automatically print the reports& network with the upper management. ? Automatically identify the train car numbers (the railway channel); ? Work environment: Temperature: -20?~+50? Humidity: Less than 95% (No condensation); ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A); ? Installation category II (voltage level should follow the provisions of IEC1010-1). Application Areas Ports, terminals, scrap metal transportation bases, air ports, Customs and so on. 13. BSRPM-9030-6 Channel-type Vehicle/Train Radioactive Automatic Monitor System Overview BSRPM-9030-6 channel-type vehicle/train radioactive automatic monitor system is the radioactive automatic monitor system which configures two large-volume, high-sensitivity gamma-ray detectors. It can real-time detect the passing through vehicle/train, find traces of the Professional Environmental Monitoring Solutions 87 radioactive materials, output the alarm and store the test data. The system can also network with the upper management systems at the same time, which will constitute a remote real-time detection information system. The systems are widely used in some places’ entrances, exits& channels, such as Customs, ports, even some metal recovery and smelting enterprises use the system to detect the small/medium trucks& cargo whether taking the radioactive materials. Technical Parameters ? Detector: 2 plastic scintillators(1200mm*500mm*84mm)+ double low-noise photomultiplier tubes, the single crystal sensitive with the volume of 50 liters. With 3mm lead (5 faces) which will screen the interference of the background, and every detector weighs about 250kg (detector+ dos shell); ? Detection of ?-rays and x-ray, energy range of 20keV ~ 3MeV; ? Controller signal processing unit: 32-bit embedded ARM9 processor; ? Monitoring area coverage: height=5.5m; width=6m; (BSRPM-9030-6 series) ? Alarm: Sound alarm& light alarm (the alarm can distinguish the alarms between radiation and over-speed), adjustable of the alarm thresholds, the alarm can be connected to a remote management computer with a special back-management software; ? Automatically identify the train car numbers (the railway channel); ? Back-up battery: Lead-acid battery, which can work 4 hours after power off (Not including the management computer system); ? The management computer system can record the traffic, the alarm data, capture images, automatically print the reports& network with the upper management. ? Work environment: Temperature: -20?~+50?; ? Humidity: Less than 95%RH (No condensation) ? The main supply voltage range 110-240VAC, 50—60Hz(less than 1A) ? Installation category II (voltage level should follow the provisions of IEC1010-1) Application Areas Ports, terminals, scrap metal transportation bases, air ports, Customs and so on.
Most popular related searches
