Radwag USA L.L.C.

Radwag - Model UYA 2.4Y PLUS - Ultra-Microbalance - Manual

User manual no: IMMU-01-03-08-14-EN BALANCES 3Y SERIES - ultra-microbalances UYA 3Y - microbalances MYA 3Y BA LAN CES AND SCAL ES RADWAG 26 – 600 Radom, Bracka 28, POLAND Phone: +48 (0-48) 38 48 800, fax. +48 (0-48) 385 00 10 export@radwag.com www.radwag.com - 2 - AUGUST 2014 - 3 - Table of Contents 1. GENERAL INFORMATION ................................................................... 8 2. UNPACKING AND INSTALLATION .................................................... 10 2.1. Balance cleaning .................................................................................. 11 2.2. Pluging to mains .................................................................................. 11 2.3. Connecting peripheral equipment ........................................................... 11 3. BALANCE DESIGN ........................................................................... 12 3.1. Dimensions ......................................................................................... 12 3.2. Interfaces ............................................................................................ 12 3.2.1. Activation ............................................................................................ 13 3.2.2. Settings .............................................................................................. 13 4. STARTUP ......................................................................................... 14 5. BALANCE KEYBOARD – FUNCTION KEYS ......................................... 14 6. SOFTWARE STRUCTURE .................................................................. 15 7. SOFTWARE WEIGHING WINDOW .................................................... 16 8. LOGGING ........................................................................................ 17 9. OPERATING USER MENU ................................................................. 18 9.1. Terminal’s keyboard ............................................................................. 19 9.2. Return to weighing mode ...................................................................... 19 10. WEIGHING ...................................................................................... 20 10.1. Selecting of measuring unit ................................................................... 20 10.2. Means of correct weighing procedure ...................................................... 21 10.3. Balance levelling .................................................................................. 22 10.4. Zeroing ............................................................................................... 22 10.5. Tarring ................................................................................................ 23 10.6. Use of air buoyancy compensation factor ................................................. 24 10.7. Additional parameters on weighing process ............................................. 27 10.8. Minimum sample .................................................................................. 29 10.9. Cooperation with TITRATORS ................................................................. 32 11. ADJUSTMENT .................................................................................. 34 11.1. Internal adjustment .............................................................................. 34 11.2. External adjustment ............................................................................. 34 11.3. User adjustment .................................................................................. 35 11.4. Adjustment test ................................................................................... 35 11.5. Automatic adjustment ........................................................................... 35 11.6. Automatic adjustment time ................................................................... 36 11.7. Adjustment report printout .................................................................... 36 11.8. GLP project ......................................................................................... 36 11.9. Adjustment history ............................................................................... 37 12. USERS ............................................................................................. 38 13. ACCESS LEVEL ................................................................................. 39 14. PROFILES ........................................................................................ 41 14.1. Creating a profile ................................................................................. 41 14.2. Profile structure ................................................................................... 42 14.2.1. Settings .............................................................................................. 42 - 4 - 14.2.2. Working modes .................................................................................... 43 14.2.3. Readout .............................................................................................. 43 14.2.4. Measuring units .................................................................................... 45 15. WORKING MODES – general information ........................................ 46 15.1. Working mode selection ........................................................................ 47 15.2. Parameters relating to working mode ...................................................... 47 15.3. Quick access keys, proximity sensors ...................................................... 48 15.3.1. Proximity sensors ................................................................................. 48 15.3.2. Automatically opened door .................................................................... 49 15.4. Information ......................................................................................... 49 15.5. Printouts ............................................................................................. 49 15.6. Profiles ............................................................................................... 52 16. PARTS COUNTING ........................................................................... 53 16.1. Ustawienia dodatkowe zwiazane z liczeniem detali .................................... 54 16.2. Parts counting – quick access keys ......................................................... 55 16.3. Setting standard (reference) mass by inserting determined part mass ........ 55 16.4. Setting standard (reference) mass by weighing ........................................ 55 16.5. Acquiring part mass from database......................................................... 56 16.6. Updating part mass in the database ........................................................ 57 16.7. Parts counting procedure ....................................................................... 57 16.8. Checkweighing function in parts counting mode ....................................... 58 16.9. Dosing function in parts counting mode ................................................... 59 17. CHECKWEIGHING............................................................................ 60 17.1. Use of checkweighing thresholds ............................................................ 61 17.2. Additional settings of checkweighing mode .............................................. 61 18. DOSING .......................................................................................... 62 18.1. Use of database of products in dosing process ......................................... 63 18.2. Additional settings of dosing mode ......................................................... 64 19. PERCENT SETUP .............................................................................. 65 19.1. Comparison of sample and (reference) mass standard .............................. 66 19.2. Checkweighing, dosing functions in percent setup mode ............................ 67 19.3. Interpreting the function by use of a bargraph ......................................... 68 19.4. Additional settings of Percent Setup mode ............................................... 68 20. DENSITY ......................................................................................... 69 20.1. Determining density of solid object ......................................................... 70 20.2. Determining density of liquid ................................................................. 71 20.3. Density of air ....................................................................................... 72 20.4. Additional setings of density mode ......................................................... 73 20.5. Printouts ............................................................................................. 74 20.6. Report on completed density determination processes .............................. 76 21. ANIMAL WEIGHING ........................................................................ 78 21.1. Setting of animal working mode ............................................................ 79 21.2. Additional settings of animal weighing mode ............................................ 80 22. FORMULATION ................................................................................ 81 22.1. Additional settings of formulation mode .................................................. 82 22.2. Formulation – quick access keys ............................................................ 83 22.3. Adding formulas to the Database of Formulas .......................................... 83 - 5 - 22.4. Using formulas in weighing .................................................................... 85 22.5. Printouts ............................................................................................. 88 22.6. Report on completed formula making processes ....................................... 89 23. STATISTICS .................................................................................... 90 23.1. Setting of keys and workspace for statistics mode .................................... 91 23.2. Additional settings of statistics mode ...................................................... 91 23.3. Parameters related to a series of measurement........................................ 92 24. PIPETTE CALIBRATION ................................................................... 94 24.1. Additional settings of pipettes calibration mode ........................................ 96 24.2. Pipettes calibration – quick access keys .................................................. 97 24.3. Adding a pipette to the database ............................................................ 97 24.4. Printouts ............................................................................................. 98 24.5. Working mode activating procedure ........................................................ 99 24.6. Report on completed calibration processes .............................................101 25. DIFFERENTIAL WEIGHING ............................................................ 103 25.1. Additional settings of differential weighing mode .....................................104 25.2. Differential weighing – quick access keys ...............................................104 25.3. Introducing a series to the Database of Series ........................................106 25.4. An example of process for differential weighing mode ..............................107 25.5. Copy tare ...........................................................................................113 25.6. Using option “SAMPLE SELECTION”........................................................113 25.7. Deleting a value ..................................................................................114 25.8. Printouts ............................................................................................115 26. STATISTICAL QUALITY CONTROL - SQC ........................................ 117 26.1. Working mode activating procedure .......................................................118 26.2. Additional settings of the SQC mode ......................................................120 26.3. Carrying out a control process ..............................................................120 26.4. Report on product control .....................................................................121 27. DATABASES................................................................................... 123 27.1. Processes carried out on databases .......................................................124 27.2. Products .............................................................................................125 27.3. Weighing records ................................................................................126 27.4. Clients ...............................................................................................127 27.5. Formulation ........................................................................................128 27.6. Reports from formulation .....................................................................128 27.7. Reports from density ...........................................................................129 27.8. Pipettes .............................................................................................130 27.9. Reports from pipette calibration processes .............................................131 27.10. Series ............................................................................................131 27.11. Raports on SQC ..............................................................................132 27.12. Minimum sample weight ..................................................................133 27.13. Ambient conditions ..........................................................................135 27.14. Packages........................................................................................135 27.15. Magazyny .......................................................................................136 27.16. Printouts ........................................................................................136 27.17. Universal variables ..........................................................................138 27.18. Operating databases ........................................................................138 - 6 - 27.18.1. Export database of weighing records to file ........................................... 139 27.18.2. Delete database ................................................................................ 140 27.18.3. Delete weighments and reports ........................................................... 142 28. COMMUNICATION ......................................................................... 143 28.1. RS 232 port settings ............................................................................143 28.2. ETHERNET port settings .......................................................................143 28.3. WiFi settings .......................................................................................143 28.5. TCP protocol settings ...........................................................................146 29. PERIPHERAL DEVICES................................................................... 147 29.1. Computer ...........................................................................................147 29.2. Printer ...............................................................................................147 29.3. Barcode scanner .................................................................................150 29.4. Transponder card reader ......................................................................150 29.5. Additional display ................................................................................151 29.6. Ambient conditions module ...................................................................151 29.7. Tablet feeder ......................................................................................152 30. INPUTS / OUTPUTS ....................................................................... 152 31. OTHER PARAMETERS ..................................................................... 155 31.1. Interface language ..............................................................................155 31.2. Date and time settings .........................................................................155 31.3. „Beep” sound ......................................................................................155 31.4. Volume ..............................................................................................156 31.5. Sleep mode ........................................................................................156 31.6. Display brightness ...............................................................................156 31.7. Touch panel calibration ........................................................................156 31.8. Level control .......................................................................................157 31.9. Sensor sensitivity ................................................................................158 31.10. Proximity sensors delay ...................................................................158 31.11. Autotest .........................................................................................158 31.12. Start logo .......................................................................................162 31.13. Export of system events...................................................................162 32. UPDATE ......................................................................................... 163 33. SYSTEM INFORMATION ................................................................. 163 34. MOVIES ......................................................................................... 164 35. COMMUNICATION PROTOCOL ....................................................... 166 35.1. Set of commands ................................................................................166 35.2. Format of a response to computer command ..........................................167 35.3. Manual printout / Automatic printout .....................................................178 36. CONNECTING PERIPHERAL DEVICES ............................................. 179 37. DIAGRAMS OF CONNECTING CABLES ............................................ 180 38. ERROR MESSAGES ......................................................................... 181 39. ADDITIONAL EQUIPMENT ............................................................. 181 40. APPENDIX A – Variables for printouts........................................... 182 40.1. List of variables ...................................................................................182 40.2. Variables formatting ............................................................................189 41. APPENDIX D – Settings of CITIZEN printer ................................... 192 - 7 - 42. APPENDINX E - Settings of ZEBRA printers .................................. 192 43. APPENDIX F – Communication with barcode scanners .................. 193 44. APPENDIX G – Menu structure ...................................................... 194 - 8 - 1. GENERAL INFORMATION INTENDED USE Balances 3Y series are intended to precise mass measurement of weighed loads conducted in laboratory conditions. PRECAUTION MEASURES ? Before first use of the balance, it is highly recommended to carefully read this User Manual, and operate the balance as intended. ? Do not operate the touch panel using sharp edged tools (knife, screwdriver, etc.). ? Place weighed loads in the center of the weighing pan. ? Load the weighing pan with loads, gross mass of which does not exceed instrument’s measuring range (maximum capacity). ? Do not leave heavy loads on the weighing pan for a longer period of time. ? In case of defect immediately unplug the instrument from mains. ? Balances to be decommissioned, should be decommissioned in accordance with valid legal regulations. ? Do not use the balance is areas endangered with explosion. The 3Y series is not designed to operate in EX zones. WARRANTY CONDITIONS A. RADWAG feels obliged to repair or exchange all elements that appear to be faulty by production or their construction, B. Defining defects of unclear origin defects and means of their elimination can only be realized with assistance of manufacturer and user representatives, C. RADWAG does not bear any responsibility for defects, losses or accidents resulting from unauthorized or inadequate performing of production or service processes, D. Warranty does not cover: • Mechanical defects caused by product exploitation other than intended, defects of thermal and chemical origin, defects caused by lightning, overvoltage in the power network or other random event, • Balance defects if it is utilized contrary to its intended use, - 9 - • Balance defects, if service claims removing or destroying product’s protective stickers which protect the balance’s housing against unauthorized access. • Mechanical defects or defects caused by liquids and natural wear, • Balance defects caused by inappropriate setting of a defect of electric power network, • Defects caused by overloading balance’s mechanical measuring system, • Maintenance activities (cleaning). E. Loss of warranty takes place if: • A repair is carried out outside RADWAG sales office or authorized service point, • Service claims intrusion into mechanical or electronic construction by unauthorized people, • Other version of the operating system is installed in a balance, • The balance does not bear company’s protective stickers. F. Detailed warranty conditions are listed on a service card. Supervision over balance’s metrological parameters Metrological parameters of a balance need to be checked by a user in determined time intervals. Inspection frequency is conditioned by ambient conditions in which a balance is used, kind of carried out processes and adopted quality management system. The manual’s significance It is very important to read the user manual carefully before switching on and starting up balance operation, even if the user is experienced and has worked with the this type of balance before. Balance user training A balance should be utilized and supervised only by users who are trained and experienced in such type of weighing instruments. - 10 - 2. UNPACKING AND INSTALLATION Carefully unpack the balance, remove plastic, cardboard and foil packagings together with protective elements and using gently movements place the balance onto its location. Assembly the weighing pan and other elements following the diagram. After installing the balance at the operating place, following elements should be set in a given order: 1 – pan shield 2 – bottom ring 3 – balance pan 4 – glass cover After the elements setting, additional devices should be connected and balance should be plugged to power source. Power socket is located at the back side of an electronic module. - 11 - 2.1. Balance cleaning 1. Disassembly the weighing pan and portable elements. Use the most gentle movements so as not to damage the mechanism. It is recommended to use tweezers while removing the pan from microbalances. 2. If possible, use vacuum keyboard cleaner to remove the dust from the weighing chamber (especially recommended for microbalances) 3. Glass parts should be cleaned using a dry flannel cloth (mild cleanser may be used if it does not contain any abrasive substances) – for draft shield disassembly instruction go to the next section of this manual 4. Use a dry flannel cloth in order to clean disassembled parts (mild cleanser may be used if it does not contain any abrasive substances) Caution: Cleaning balance’s weighing pan if installed may damage instrument’s measuring mechanism. Upon completing the cleaning process reassembly the balance elements. When compared to disassembling process reverse order of actions must take place. 2.2. Pluging to mains The balance should be plugged to mains using the original power adapter, which is balance’s standard equipment. Plug the power adapter’s plug to balance’s socket located at the back of the housing. 2.3. Connecting peripheral equipment Use only accessories and peripheral equipment recommended by the manufacturer of your balance. The balance must be disconnected from the mains before connecting or disconnecting any peripherals (printer, PC computer, computer keyboard). On connecting the peripherals, plug the balance to mains. - 12 - 3. BALANCE DESIGN 3.1. Dimensions 3.2. Interfaces Available interfaces overview 1 – Ethernet RJ45 2 – RS232 interface (COM1) 3 – USB port 4 – IN/OUT, RS232 (COM2) - 13 - Interfaces RS232 and WE/WY RS232 - socket DB9/M (male), front view: Pin2 - RxD Pin3 - TxD Pin5 - GND IN/OUT, RS232 socket DSUB15/F (female), front view: Pin1 - GNDWE Pin2 - OUT1 Pin3 - OUT2 Pin4 - COMM Pin5 - 6÷9VDC Pin6 - IN4 Pin7 - IN3 Pin8 - TxD2 Pin9 - 5VDC Pin10 - GNDRS Pin11 - IN2 Pin12 - IN1 Pin13 - RxD2 Pin14 - OUT4 Pin15 - OUT3 3.2.1. Activation On unpacking and placing the balance onto its workstation it is necessary to connect the weighing module and the terminal to mains. Next, the user shall proceed like in case of a standard design activation (description to be found further down this manual). 3.2.2. Settings For ensuring long enough operation while powering the device by means of battery, the correct parameters of group OTHER must be set, . For more information refer to point 33 of this manual titled OTHER PARAMETERS. - 14 - 4. STARTUP • On plugging the balance to mains, instrument’s diode ON/LOAD located on indicator’s housing is lit up. • Press powering key located on the upper left section of terminal’s overlay. Within a few seconds, the OS Windows CE and RADWAG software start loading, which is signalled by flickering red diode ON/LOAD. • On completing the startup procedure, the instrument’s displays main window of the balance software. • The balance starts up with no user logged in. In order to start operation, a user has to log in. (logging procedure is described further in this user manual). Caution: Remember to start the balance with no load on the weighing pan. 5. BALANCE KEYBOARD – FUNCTION KEYS Key Description Switching the instrument ON / OFF Zeroing Tarring Sending measurement result to a plugged printer or computer Function key (entering instrument’s menu) Working mode selection, (programmable key) User profile selection, (programmable key) Internal adjustment, (programmable key) - 15 - 6. SOFTWARE STRUCTURE The structure of balance’s main menu is divided into function groups. Each group comprises parameters grouped by their reference. Description of each menu group is provided further in this user manual. List of groups - Parameters Balance’s main menu is accessed by pressing SETUP function key or soft key located in the bottom tool bar of balance’s display. The menu comprises parameters referring to balance settings, functions and profiles. ADJUSTMENT USERS PROFILES DATABASES COMMUNICATION PERIPHERALS INPUTS/OUTPUTS ACCESS LEVEL OTHERS UPDATE INFORMATION ON SYSTEM - 16 - 7. SOFTWARE WEIGHING WINDOW The software’s main window is divided into 4 main sections: • The upper part of the touch panel displays data on active working mode, logged operator, date, time, active connection to a computer and current level status of a balance. • Below there is a weighing window, indicating measurement result and current measuring unit • Under which there is a grey coloured workspace containing additional data on weighing process and activities Caution: Data contained in the workspace is optionally configurable. Configuring process is described in point 15.4 of this user manual; • Below the workspace there is a set of soft keys: Caution: Balance user can declare the presence of function (quick access) keys. Declaring process is described in point 15.3 of this user manual; - 17 - 8. LOGGING Full access to balance’s parameters and editing databases requires logging to instrument’s software as an operator with access level. The logging procedure should be carried out on each switching on the balance. Log in procedure • While in main weighing window of the application, press text located in the upper window bar, which opens a window with operators database including < Admin>entry, • On entering the < Admin> entry, the software activates on-screen keyboard for entering operator’s password, • Insert password “1111” and accept it by pressing key, • The software automatically returns to displaying the main window, and the display’s upper bar indicates word instead of , • After first logging in, the administrator should add user profiles and set their corresponding access level (the procedure of assigning access levels is described further in this user manual, see point 12 and 13). On future logging in, select a user from the list, and on entering password, balance’s software initiates operation with access level set for a corresponding user. Log out procedure • While in main weighing window of the application, press name of a logged operator located in the display’s upper bar. A window with operators database is opened, • Press soft key (located as position no. 1 in the list of operators) • The software returns to the main window, and the display’s upper bar indicates word instead of name of a logged operator. Access levels 3Y series software provides four access levels: administrator, advanced operator, operator and none (anonymous logging). On switching on the balance, its display is constantly active, enabling carrying out mass measuring processes. These measurements, however, cannot be saved in balance’s database unless a user with at least minimal access level is logged in. The minimal access level enables carrying out mass measuring processes and saving them in balance’s databases using available function keys. - 18 - Below table indicates access to editing user parameters, databases and software functions depending on active access level. Authorization Access level None (guest) No access to editing all of user parameters. It is not possible to accept a weighing record nor to start a process. No access to menu . Operator Access to editing parameters in submenu: and settings in group of parameters , except for . The operator can start and carry out all weighing processes, and has access to and preview data in . An operator can define universal variables. Advanced operator Access to editing parameters in submenu: ; ; ; ; except for . The advanced operator can start and carry out all weighing processes, and can erase old data from the . Administrator Access to all user parameters, functions and editing databases. 9. OPERATING USER MENU Moving in menu of balances 3Y series is intuitive. The touch panel makes the operation of balance’s software very simple. Pressing a function key, a soft key or area on the display initiates an assigned function or process. - 19 - 9.1. Terminal’s keyboard or Enter main menu Scroll menu upwards Scroll menu downwards, Fast up and down menu scrolling, Accept changes, Leave a function unchanged (without saving changes), Add items to a database, Search for items in a database by date Search for items in a database by name Search for items in a database by code Printout of an item from a database Clear the editing field Activate / deactivate on-screen keyboard Reading printout template from a file format *.lb (function key is active on plugging a data storage device to terminal’s USB port) Selection of variables from a list for a printout Moving (exiting) one level up in menu structure 9.2. Return to weighing mode Changes in instrument’s memory are saved permanently on returning to weighing mode. Procedure: - Press key for a few times, until the display indicates to the weighing mode. - press soft key in the upper bar on the display. The software immediately returns to displaying the main window. - 20 - 10. WEIGHING Load a weighed object on balance’s weighing pan. On stabilization of weighing result, indicated by stability marker visible on the side of balance’s display, read the measurement result. Saving / printout of the measurement result is available on pressing key: • In case of verified balances – only stable measurement result can be saved or printed (stability marker visible on balance’s display) • In case of non-verified balances – stable or unstable measurement result can be saved or printed (regardless of stability marker presence). If unstable measurement result is printed then it is accompanied by question mark in front of printed mass value. 10.1. Selecting of measuring unit Change of measuring unit is carried out by pressing the measuring unit icon visible next to the value of measurement result on balance’s display. Pressing the measuring unit icon opens a list with available units. On selecting one of them, the software automatically calculates the indicated mass value to the active measuring unit. Available measuring units: Unit Denotation Verified balance gram [g] tak miligram [mg] tak* kilogram [kg] tak* carat [ct] tak* pound [lb] nie ounce [oz] nie ounce Troy [ozt] nie pennyweight [dwt] nie Taele Hong Kong [tlh] nie Taele Singapore [tls] nie Taele Taiwan [tlt] nie Taele China [tlc] nie Momme [mom] nie Grain [gr] nie Newton [N] nie Tical [ti] nie - 21 - * - Accessibility of measuring units is conditioned by type of balance and its verification status. In non-verified balances all measuring units including those outside the International System of Units are available. 10.2. Means of correct weighing procedure In order to ensure long lasting use of a balance, correct and reliable measurement of weighed loads, follow below procedures: ? Start the balance with no load on the weighing pan (permissible value of load on the weighing pan on balance start is ±10% of its maximal capacity). ? Load the weighing pan steadily avoiding shocks: YES NO ? Place weighed loads centrally on the weighing pan: YES NO ? Avoid side loading, in particular side shocks: NO NO - 22 - 10.3. Balance levelling Balance Y2 series features AutoLEVEL System, which continuously monitors balance’s level status during its operation. The level status is signaled in the upper right corner of balance’s display. The system continuously controls level, and on detecting level change it indicates appropriate information on the display and/or signals an alarm. Then the software opens a window for adjusting the level. Balance levelling procedure • Press level status pictogram< > located in the upper right corner of the display. • The display indicates a control panel of leveling function. Balance operator previews level status, and balance’s top elevation. • Level the balance by turning the adjustable feet in a way indicated by blinking pictograms on the display < > – the level point should move towards the center of the level circle. • As the level point is in the center point, its colour changes from red to green – which is a confirmation for correct level status. Caution: The balance is equipped with Automatic Level Control mechanism. Description to be found in point 33.7 of this manual. 10.4. Zeroing In order to zero mass indication press key. The mass indication on the display should equal zero, and precise zero and stability markers should appear. Zeroing process is tantamount to determining new zero point recognized by the balance as precise zero. Zeroing is possible only in stable status of display indication. Caution: Zeroing the display indication is possible only within the ±2% range of instrument’s maximal capacity. If zeroed value is above the ±2% of the maximal capacity, then the software indicates an error message Err2. - 23 - 10.5. Tarring In order to determine net weight of a weighed object, place object’s container (packaging) on balance’s weighing pan, and on stabilization of measurement result press key. The display should indicate mass equal to zero and symbols: Netand . On taking off the weighed load and its packaging from instrument’s weighing pan, the display indicates sum of total tarred mass with minus sign. The software also enables assigning tare value to a product from a database. Then, on product selection from a database, the software automatically uploads data on tare value for the specific product. Caution: Tarring negative values is impossible. On tarring negative values the balance responds with an error message. In such case zero balance’s indication and repeat tarring procedure. Manual tare determination Procedure: • While in optional mode press quick access key , • Which opens numeric keyboard on balance’s display, • Using numeric keys insert desired tare mass and press key, • The balance returns to weighing mode, and the display indicates inserted tare value with minus “–“ sign. Deleting tare The tare value indicated on balance’s display can be deleted by pressing ZERO key on balance’s front panel, or using programmable function key PROCEDURE 1 – on taking the tarred load off balance's weighing pan * Press ZERO key * The NET marker is deleted, and new zero point of the balance is determined PROCEDURE 2 – when the tarred load in on balance’s weighing pan * Press ZERO key * The NET marker is deleted, and new zero point of the balance is determined * If tare value exceeds 2% of balance’s maximal capacity, the display indicates error message –Err- (forbidden operation) PROCEDURE 3 - when the tarred load in on balance’s weighing pan or on taking the tarred load off balance's weighing pan * Press programmable key * The NET marker is deleted, * The display indicates tare value * Press key to restore the last tare value - 24 - 10.6. Use of air buoyancy compensation factor The application enables correcting mass measurement errors during: 1. Weighing loads that density considerably differs from the density of standard used to adjusting the balance. Regularly, the balance is adjusted with a steel mass standard with density ~8.0g/cm3 or a brass mass standard with density ~8.7g/cm3. If loads made of other substances are weighed, then ratio indicated on below chart should apply. Below chart presents the value of mass correction in relation to the density of weighed load, assuming that air density is constant and equals 1.2 kg/m3. Correction value [mg] Density of weighed load Sample mass [g] Error value in relation to density of weighed sample 1. Testing the changes of sample mass within a few hours’ time, if: sample mass is relatively constant (minor changes). In such case it is assumed, that considerable effect on the measurement result rests on air density changes, which is affected by changes of pressure, temperature and humidity. In order to carry out a reliable measurement, apart from being familiar with relations applying to ambient conditions, an operator should know the measuring methods, features of tested sample, air density in the laboratory room and density of weighed sample. - 25 - FUNCTIONING The application provides two ways to use the air buoyancy compensation procedure. 1. Inserting the specified value of air density and specified value of weighed sample density to balance’s memory. On inserting these values the application automatically calculates the correction factor for weighed mass and indicates corrected value of weighed mass on balance’s display. In order to avoid errors, the corrected mass value is accompanied by <> symbol visible on balance’s display and a printout. 2. The application semi-automatically determines the value of air density. The specified density of the weighed sample is inserted to balance’s memory by an operator. Determination of air density is carried out using a set of two mass standards. One of them is made of stainless steel, and the other of aluminum. Based on mass indications of the two standards, the software automatically calculated the air density and saves the value in balance’s memory on operator’s confirmation. Then the density of weighed sample has to be inserted to balance’s memory. On inserting these values the application automatically calculates the correction factor for weighed mass and indicates corrected value of weighed mass on balance’s display. As in case 1, the corrected mass value is accompanied by <> symbol visible on balance’s display and a printout. Air buoyancy conmpensation mode is enabled / disabled from the level of user menu. The application is operating in weighing mode only. STARTUP AND OPERATION OF AIR BUOYANCY COMPENSATION PROCEDURE • While in main window press grey coloured workspace • Select option • Select parameter < Air buoyancy compensation> Accessible settings - Air buoyancy compensation – YES/NO - Sample density (insert the density value of weighed sample). If an operator uses products from databases, then on product selection its density value is automatically uploaded. - Air density – for selecting the means of inserting the air density - 26 - value used for calculating buoyancy correction factor. Settings: VALUE – selecting this option opens a window for inserting determined value of air density (e.g.: determined using other methods). The inserted value is used to calculating buoyancy compensation factor. The value is assigned automatically on carrying out the air density determination (on its completion by pressing < > key). ONLINE – selecting this option downloads current air density value from a connected THB sensor, if such is connected to the balance, or from internal sensor installed in the balance. If a balance features both types of sensors (THB module and internal sensor), then data from the THB module supersedes the other, and parameters Setup/Ambient Conditions/Ambient Conditions Module require setting to SAVE or SAVE & ALERTS mode. If a balance features only one type of the sensors for temperature, humidity and pressure recording, then correct ONLINE operation requires setting of balance parameters: - Internal sensors only - Setup/Ambient Conditions/Ambient Conditions Module set to NONE, - External THB module only - Setup/Ambient Conditions/Ambient Conditions Module set to SAVE or SAVE & ALERTS mode. Additionally, for correct balance cooperation with the THB module set port’s transmission parameters to compatible with those of the THB module. the THB module transmission parameters are detailed on its data plate. On returning to the weighing mode, the display indicates an additional symbol <>, as indicated on below drawing.From now on the value of indicated mass is corrected including the air buoyancy compensation factor and sample density. The measurement result can only be compensated by a correct value if an operator inserts to balance’s memory the actual value on the air density and correct density of weighed sample. Caution: If the mode is set to value, then balance display does not indicate pictogram <> which means that parameter Setup/Ambient Conditions/Ambient Conditions Module is - 27 - set to SAVE or SAVE & ALERTS mode, and there is no physical connection between a balance and a THB module, or the parameters for communicating the module with the balance are set incorrectly. In such case plug a THB module to balance’s ports COM 1 or COM 2 and set appropriate cooperation parameters, such as specified on module’s data plate. 10.7. Additional parameters on weighing process Changes in settings of functions related to weighing process can in some extend program balance reactions. Procedure: 1. Press grey coloured workspace 2. Balance display indicates menu: Settings, Keys, Information, Printouts, Profile 3. Press one of available submenu options and select item for modification, Menu - additional options related to weighing mode Menu - defining quick access keys Menu - supplementary data on weighing process displayed in the grey coloured workspace Menu - selection of printout type Menu - selection of profile, active during balance operation Menu - contains supplementary data on weighing process, such as: - Tare mode • SINGLE, mass value stored in balance memory on single pressing of TARE key, the following pressing of TARE key determines new value of tare. Selection of product or packaging with assigned tare value causes automatic deleting of previously assigned tare value; • SUM OF ACTIVE, totalizing applied tare values for a product or a packaging (resulting from selecting a product or a packaging from corresponding database) with a possibility of increasing determined tare value by manual tare introduced manually using balance’s numeric keyboard. On following determining of tare value for a product or a packaging, the tare value introduced manually is deactivated. • SUM OF ALL, totalizing all introduced tare values. • AUTOTARE Means of operation: Each first stable measurement result is tarred. The NET pictogram flashes on the display. The operator can determine net mass of weighed load. On taking off the load from balance’s weighing pan, and as the - 28 - indication returns to autozero zone, the software automatically deactivates Tare value. - Automatic footer printout Accessible options: MODE - No – manual footer printout, Sum of measurements – the condition for printing a footer is exceeding mass value set in parameter Number of measurements – the condition for printing a footer is carrying out a pre-defined number of measurements (a batch) set in parameter THRESHOLD – setting the value of threshold determining footer printout. For option the value is determined in measuring unit [g], and for option the value is not measurable, and determined by number of carried out measurements. - Printout mode / printout release • Function key PRINT / printout release, (manual operation) Never – printout deactivated First stable – the first stable measurement is printed Each stable – all stable measurements are set for printing Each – printout of all measurements (stable and unstable), in case of a verified balance only stale measurement results are printable (as in setting ) • AUTOMATIC MODE Never – printout deactivated First stable – the first stable measurement result obtained after placing a load on balance’s weighing pan is recorded, record of the following measurement result takes place only on unloading the weighing pan, returning of the mass indication below set threshold’s value, and placing another load on balance’s weighing pan Last stable – accepted is the last stable measurement recorded before taking the load off the weighing pan. The record takes place on taking the load off the balance’s weighing pan, and returning of the mass indication below set threshold’s value. • THRESHOLD mass value obligatory for operation of automatic printout. Set in grams. - 29 - - Printout Contains type of printout that is related to a working mode. Printout takes place on pressing PRINT key on balance’s overlay. Accessible options: • STANDARD PRINTOUT Possible declaration of printout content: HEADER, WEIGHING DATA and FOOTER. printout components marked as in the menu are printed on pressing printout activating function key. • NON-STANDARD PRINTOUT Database of printouts enables selecting one of available non-standard printouts visible in menu , or designing a unique printout which is automatically added to the databases. Caution: Means of designing printouts is described in point 15.5 of this user manual. - Air buoyancy compensation Contains parameters allowing the user to switch on the correction and enter data relating to density of the sample and to density of the air. Caution: function operates only for weighing mode. For instruction and information on air buoyancy compensation operation see the previous section of this manual. 10.8. Minimum sample The weighing mode settings comprise a function of . The function is enabled on specifying in the database parameters on methods for determining the minimum sample and the values of minimal sample weight specific for a method. In standard version, this database item is not filled in with data. Activities related to determining minimum sample and adding data to the database: are accessible only for an authorized “RADWAG” personnel. Should balance operator use the minimum sample mode, and data on minimal sample weight are not entered to balance menu, then please contact the local representative of “RADWAG” company. An authorized RADWAG representative determines the minimum sample dependent on packaging mass. The process is carried out with mass standards, in balance place of use and in accordance with the requirements of the accepted quality system. The obtained values are entered to balance software: . A minimum sample determining method may have a few tare values defined, along with assigned values of minimum samples, expiry dates of the carried out measurements and entered data. The settings are not to be edited by balance user. - 30 - Using mode guarantees that the results of completed weighing processes are within set tolerance limits, and they comply with the requirements of the quality system accepted by an organization. Caution: the mode operates in the weighing mode only. Available options: • METHOD It is a means for designating an accepted quality standard. Pressing a field displays a window with a list of minimal sample weight values stored in balance’s memory, following a criterion on determining the minimum sample. Adding a new method is available only from the menu level • MODE Lock – on selecting this option and during the weighing process the display indicates corresponding pictograms that inform a user whether the weighed mass is below or above the minimum sample limit. Additionally the software disables accepting the measurement result if it is below the minimum sample limit Warn – on selecting this option and during the weighing process the display indicates corresponding pictograms that inform a user whether the weighed mass is below or above the minimum sample limit. The user can accept a measurement that is below the minimum sample limit, but on a printout such measurement is preceded by an asterisk (*). Caution: Means of setting a method of minimum sample determining is described in point 27.9. of this user manual: . RADWAG authorized personnel is only authorized to add new values of minimum samples. Weighing with application of mode If during a weighing process a user wants to be informed whether a measurement exceeds the minimum sample limit for a specific weighing threshold, then the mode has to be enabled in the additional setting of the weighing mode. Procedure: 1. Press grey coloured workspace 2. The display indicates menu: Settings, Keys, Information, Printouts and Profiles 3. Select menu - additional options on weighing process 4. Press < Minimum sample> field 5. Below window is opened - 31 - 6. Press field 7. Which opens a window containing a list of minimum sample methods stored in balance database. 8. Select one of available entries. 9. The software returns to the previous menu window 10. Press field 11. Which opens a window with parameter settings. Select one of below options: Lock – on selecting this option and during the weighing process the display indicates corresponding pictograms that inform a user whether the weighed mass is below or above the minimum sample limit. Additionally the software disables accepting the measurement result if it is below the minimum sample limit Warn – on selecting this option and during the weighing process the display indicates corresponding pictograms that inform a user whether the weighed mass is below or above the minimum sample limit. The user can accept a measurement that is below the minimum sample limit, but on a printout such measurement is preceded by an asterisk (*). 12. On setting the parameters exit the menu. 13. The mass field on the display is supplemented by an additional informative pictogram. The pictogram changes during weighing process and indicates current status of mass in relation to the pre-determined value of minimum sample. - Mass below the set value of minimum sample - 32 - - Mass above the set value of minimum sample for a given tare range Meaning of the pictograms of minimum sample mode: Mass below the set value of minimum sample. Mass above or equal to the value of minimum sample. Mass below the set value of minimum sample. A pictogram with a clock informs on approaching expiring of the validity period of the minimum sample (it is displayed two weeks before the determined expiry date). Mass above the set value of minimum sample. A pictogram with a clock informs on approaching expiring of the validity period of the minimum sample (it is displayed two weeks before the determined expiry date). The validity term of the minimum sample has expired. Changes are needed in the minimum sample settings. Only authorized RADWAG personnel can change the minimum sample settings. Caution: If more than one reference tare value is programmed (with corresponding minimum sample mass) then the indicated value automatically moves to a range corresponding to the weight of the tarred container. At the same time the required minimum mass is changed. 10.9. Cooperation with TITRATORS In order to ensure correct cooperation with TITRATORS it is necessary to set option to value. The setting must be done for standard printout content. Any other variables for this printout must be off. - 33 - If the option is on, the user shall notice an icon informing about specific mass printout format accepted by TITRATORS. The icon is located in the top toolbar of the main window. - 34 - 11. ADJUSTMENT Balances 3Y series feature automatic internal adjustment system which ensures correct measurement accuracy. Menu contains functions controlling operation of balance adjustment process, including options: 11.1. Internal adjustment Internal adjustment process utilizes an internal weight built in balance’s housing. function key activates automatic adjustment process. On its completion, balance’s display indicates a message box on process completion and its status. Caution: Balance adjustment requires stable measurement conditions (free from air breeze and vibrations), adjustment process has to be carried out with empty weighing pan. 11.2. External adjustment External adjustment is carried out using an external adjustment weight, with appropriate accuracy and mass relating to balance’s maximal capacity and readability. The process takes place semi-automatically, and the following process phases are indicated on balance’s display. Caution: External adjustment is available only in balances which are not subject to conformity assessment (verification). Process course: • Enter submenu < Adjustment > and select option: “ External adjustment”, • Balance’s display indicates the following message box: • If there is a load on balance’s weighing pan, unload it, • Press key. The balance determines start mass, which is indicated by a message box: “Start mass determination” on balance’s display • On determining the start mass, the balance display’s a message box: - 35 - • Acting according to the command, place an ordered weight/standard on balance’s weighing pan and press key, • On completing the adjustment procedure the balance indicates a message box: • On confirming the message box with key, the balance returns to weighing mode. 11.3. User adjustment User adjustment is carried out with an optional standard, which mass ranges between 0,15 Max and Max. Adjustment procedure is compatible with the external adjustment process, but before its start the software opens a message box for entering mass of a standard used for user adjustment. Caution: User adjustment is available only in balances which are not subject to conformity assessment (verification). In order to start user adjustment, enter submenu < Adjustment >, and select option: “ User adjustment”. Then follow the commands indicated on balance’s display. 11.4. Adjustment test function enables comparing the result of internal automatic adjustment with the value of internal weight saved in balance’s factory parameters. The comparison is used for determining balance’s sensitivity drift over time. 11.5. Automatic adjustment This menu option is used for selecting a factor which determines start of automatic adjustment process. Accessible options: ? None – automatic adjustment disabled - 36 - ? Time – adjustment takes place in time intervals declared in menu (11.6) ? Temperature – adjustment is triggered by temperature change only ? Both – adjustment activation is triggered both by temperature changes and time interval changes Caution: Changing the settings of automatic adjustment is enabled only in balances which are not subject to conformity assessment (i.e. non-verified balances). 11.6. Automatic adjustment time < Automatic adjustment time > determines time interval in which automatic internal adjustment of a balance is activated. The time interval is declared in hours and ranges between 1 and 12 hours. Setting time interval of automatic internal adjustment: ? Select option < Automatic adjustment time > ? Using displayed menu select appropriate time interval (given in hours) which is a time gap elapsing from the last carried out internal automatic adjustment until activating the following automatic internal adjustment. Caution: Changing the settings of automatic adjustment is enabled only in balances which are not subject to conformity assessment (i.e. non-verified balances). 11.7. Adjustment report printout Parameter < Report printout > determines whether or not a report on automatic internal adjustment should be automatically printed on its completion. Setting automatic report printout on adjustment completion. Go to parameter: < Report printout > and select option . 11.8. GLP project GLP is one of means for maintaining documentation from work in accordance with adopted quality system. Data selected for printing are printed on each release of a report on balance adjustment. Balance operator can use in a GLP report below listed information and signs: ? adjustment (adjustment mode) ? working mode (name of a working mode) ? date, time, ? user, ? balance type, ? balance ID, ? level status, ? nominal mass, ? current mass ? difference ? temperature, ? blank line, - 37 - ? dashes, ? signature, ? non-standard printout. 11.9. Adjustment history Contains data on all carried out adjustment processes. The record is carried out automatically. Each entry on adjustment comprises basic data on completed process. Balance menu enables displaying the list of completed adjustment processes, and each report is printable. Printing a report on adjustment process. Enter submenu < Adjustment >, and: , then select for printing adjustment entry from a list. On displaying details of a record, press print soft key < > on display’s upper bar. Hint: If memory for records on completed adjustments is full, then the oldest record is automatically erased. If internal procedures of an organization require maintaining complete documentation from all carried out adjustment processes, then the list with records on adjustment should be periodically printed and filed. Searching for adjustment record Balance enables searching for a specific record from completed adjustment processes: – Press search icon and insert date of adjustment process. Exporting data on completed adjustment process Connect a data storage device to balance’s USB port. Press key located in the upper right corner of balance’s display. The process is fully automatic, and on its completion, a file with extension *.tdb is saved on a data storage device connected to the USB port. The file is editable using Excel spreadsheet or a text editor. - 38 - 12. USERS Menu “Users” contains list of balance operators, who are authorized to operate the instrument. The following data can be defined for each balance user: ? Name ? Code ? Password ? Access level ? Language ? Profile ? Card no. Adding new user can only be carried out by balance’s Administrator. Procedure of adding a new user: In menu Users press soft key, - Which opens a message box on the display:, accept by pressing corresponding key - Define all necessary fields for a new created balance user Caution: Search for a user in database of users by code or name. Edit data on a user: - Press field with name of a user - The display indicates data on a specific user - Select and change necessary data Deleting a user can only be carried out by balance’s Administrator. To delete a user: - Press and hold user name - A menu is opened referring to a user record - Select option - 39 - 13. ACCESS LEVEL Access level in a balance determines scope of activities that a user can carry out. This menu can only be modified by balance’s Administrator. Anonymous user Balance Administrator can grant access level to a balance user who is not logged in (i.e. Anonymous user). Procedure: Enter group of parameters < Access level>, select option < Anonymous user>, and set appropriate access level for the anonymous user. Available access levels for an anonymous user: Guest, User, Advanced User, Administrator. Caution: Setting access level causes that logged user has no permission to change any settings on a balance. Date and time Balance default settings enable a user logged as the Administrator changing date and time settings. However, the software also enables changing required access level to modify option < Date and time>. Procedure: Enter group of parameters < Access level>, select option < Date and time>, and set desired access level required to modify the settings. Available access levels for changing date and time settings are: Guest, User, Advanced User, Administrator. Caution: Setting provides free access to date and time settings (no need to log in). Printouts Balance default settings enable a user logged as the Administrator editing default printout templates. However, the software also enables changing required access level to modify option < Printouts>. Procedure: Enter group of parameters < Access level>, select option < Printouts>, and select one of available options: Guest, User, Advanced User, Administrator. Caution: Setting access level provides free access to printouts settings (no need to log in). - 40 - Databases Balance Administrator is also authorized to set access level required to modifying each of the databases. Procedure: Enter group of parameters < Access level>, select option < Databases>, and set desired access level: Guest, User, Advanced User, Administrator for each of the databases. Caution: Setting access level causes that access to editing each of the databases is free. - 41 - 14. PROFILES A Profile is a data pack determining: o functioning of working modes, e.g. parts counting, percent setup, etc., o what data is displayed during working mode operation, o which function keys are active, o which measuring units are accessible o which criteria are mandatory for balance’s speed of operation and measurement stability, Balance software enables creating numerous profiles, which in practice provides: o each balance user to create their own and individual operating environment o balance operation can be easily programmed by activating function keys and information on process which are (improving ergonomics of operation) 14.1. Creating a profile A default profile in a balance is named . Balance Administrator can create new profiles by: - Copying an already existing profile and its modification, - Creating a new profile. Copying an existing profile Procedure: • Enter balance’s main menu by pressing Setup key, • Enter submenu < Profiles>, • Press and hold an entry with profile name that should be copied, • A menu is opened referring to available options: o Edit o Delete o Copy o Cancel • Select option • A new profile is created named , and all setting are identic with the copied profile, • After copying change necessary data in a profile: (name, etc.) Creating a new profile Procedure: • Enter balance’s main menu by pressing Setup key, • Enter submenu < Profiles>, • Press key, which opens a message box: , • Accept the message box by pressing key. The software automatically adds a new record and enters its editing mode. Caution: Adding a profile is only enabled after logging in as an Administrator. - 42 - Deleting a profile Procedure: • Enter balance’s main menu by pressing Setup key, • Enter submenu < Profiles>, • Press and hold an entry with profile name that should be deleted, • A menu is opened with a list. Select option from the list, • A message box is displayed which requires confirming profile’s deleting: , • Accept the message box by pressing key, the profile is deleted. Caution: Deleting a profile is only enabled after logging in as an Administrator. 14.2. Profile structure Each profile contains the following entries: Settings This menu enables setting an individual profile’s name (a sequence of alphanumeric characters), and declaring a default working mode (the selected mode is activated as default on profile selecting). Working modes Contains the following submenu: ? Additional setting of a working mode ? Function keys ? Displayed information ? Printouts Readout Contains the following submenu: ? Filter ? Value release ? Autozero ? Autozero: Dosing ? Last digit Units Menu enables declaring the start unit, the supplementary unit, 2 custom units and entering the value of gravitational acceleration force in balance’s operation place. 14.2.1. Settings Name On entering this option, the display opens a message box with keyboard. Insert name of a profile and accept it by pressing key. The name is assigned to the profile. Default working mode On entering this option the user can select a specific working mode, which is set as default in a profile. In case option is selected, then on selecting the profile, the balance activates last used working mode. - 43 - 14.2.2. Working modes On entering this option, the display opens a window containing all accessible working modes. The user can introduce their settings to each of the working modes which are activated on selecting a specific profile. In each of the working modes, the user can change the following parameters: ? Settings contain specific parameters relating to a working mode and universal settings, such as: result control, tare mode, automatic footer printout, printout mode, printout. ? Functions of quick access keys declaring quick access keys, which are visible in the bottom display bar ? Information declaring information which is visible in the grey coloured workspace ? Printout declaring type of printout of defining a non-standard printout 14.2.3. Readout The function enables the user to adjust balance operation to ambient conditions (filter settings) or individual user needs. Menu contains the following elements: FILTER Each measurement signal before being displayed is electronically processed for the purpose of obtaining corrected parameters specific for stable measurement result, i.e. ready to read. Balance user can influence to some extend the range of signal processing by selecting an appropriate FILTER value. Available options: o very fast o fast o average / normal o slow o very slow While setting the filtering level the user should consider the actual operating conditions of a balance. In case of very good operating conditions set the filter to average/normal or fast, in case of rough conditions set the filter to slow or very slow. Caution: ? in case of precision balances 3Y series the recommended range of filter is between very fast ÷ average/normal; ? in case of analytical balances and microbalances 3Y series the recommended range of filter is between average/normal ÷ very slow. - 44 - Value release This parameter determines displaying the stability marker for a measurement result. There are 3 available settings of value release parameter o fast o fast + reliable /recommended/ o reliable Caution: The speed of stability marker occurrence depends on applied filter value and applied value release. Autozero function The function is to automatically monitor and correct zero indication of a balance. If the function is enabled, the following measurement results are compared to each other in constant time intervals. If the results differ less than declared AUTOZERO range, e.g. 1 division, the balance is automatically zeroed, and the markers of stable indication and precise zero are displayed. Active AUTOZERO means, that each measurement starts from the precise zero point. There are, however, cases where the function may disturb the weighing process. For instance during very slow load placing or pouring onto the balance’s weighing pan. In such case, the correcting system of zero indication may also correct the actual indication of a load placed on the weighing pan. Accessible settings: NO - autozero function disabled YES - autozero function enabled Autozero function: Dosing The function sets autozero operation mode to default one set for dosing mode. Accessible values: NO - autozero operation is automatically disabled on entering dosing mode YES - autozero operation is automatically enabled on entering dosing mode Last digit The function determines visibility of the last decimal place indicated on measurement result. The functions provides three settings: - ALWAYS: al the digits visible - NEVER: last digit invisible - WHEN STABLE: last digit visible only for a stable measurement - 45 - Ambient conditions This parameter refers to ambient conditions of the balance. By default the parameter is set to value Stable but it is advisable to set the parameter to value Unstable for unstable ambient conditions. Stable setting results in faster operation, i.e. weighing takes much less time than in case of setting to value unstable. - Niestabilne - Stabilne 14.2.4. Measuring units Balance user can declare in a profile: start unit, supplementary unit and two custom measuring units. A custom measuring unit features: o A multiplier o A name (3 characters) If a custom unit is designed, then its name is added to the list of accessible measuring units. This menu additionally enables inserting the value of gravitational acceleration force for balance’s place of use. It is obligatory should a balance be used to determine mass in [N]. - 46 - 15. WORKING MODES – general information A balance 3Y series in its standard version features the following working modes: Weighing Means of operation: weight of a load is determined through an indirect measurement. A balance measures gravitational force which attracts the load. An obtained result is processed to a digital format and displayed in a form of measurement result. Parts counting Means of operation: based on a determined mass of a single part it is possible to count another parts, assuming that mass of a single part is determined with sufficient accuracy, and that the following parts are equal in mass. Checkweighing Means of operation: control of sample mass with applied thresholds. A user should specify the value of low threshold and high threshold . Dosing Means of operation: a user should specify sample’s target mass to be obtained by pouring. Percent setup Means of operation: control of percent ratio of a sample in relation to a standard (reference). Obtained data provides percent ratio on how test sample differs from the accepted standard (reference). Density Means of operation: based on Archimedes principle, a balance determines density of solids and liquids. The mode requires an optional density determination kit. Animal weighing Means of operation: mass measurement takes place with application of filters dampening animal moves on a weighing pan, thus enabling obtaining a correct measurement result. Formulation Means of operation: by adding a sequence of ingredients, a user can prepare an optional mixture or formulation. Before mixing balance software requires designing a formulation by specifying its ingredients and their mass. Statistics Means of operation: carried out measurements are used to calculate statistical data, such as Min, Max, deviation, etc. Pipette calibration Means of operation: calibration of pipettes according to procedures listed in ISO 8655 or according to user requirements. - 47 - Differential weighing Means of operation: analysis of mass sample change over time. Statistical Quality Control Working mode is intended to carrying out different types of product packing processes and aimed at monitoring and / or controlling the packing process. It enables detecting excess or lack of product quantity in a packaging. The settings of separate working modes include special functions specific to a mode. They enable adapting mode’s operation to user’s individual needs. The special settings are activated on selecting a corresponding profile. A detailed description of special functions is provided while presenting each of working modes. 15.1. Working mode selection Changing working mode: o Press name of active working mode, displayed in the left corner of the upper bar. o List of available working modes is displayed, o Select name of a desired working mode, and press it. 15.2. Parameters relating to working mode Each working mode has programmable parameters determining its functioning. Procedure of determining these parameters: 1. Press grey coloured workspace area. 2. Below menu is displayed: o - additional options related to a mode, o - defining quick access keys, o - selecting information displayed in the workspace, o - selecting type and content of a printout, o - selecting a profile, which is active during balance’s operation, - 48 - 3. Press corresponding menu item and select area for modification. Description of basic parameters accessible in tab is provided in point 10.8 of this user manual “Additional parameters on weighing process”. Other parameters specific to each of working modes are presented in working modes description. 15.3. Quick access keys, proximity sensors Balance user can define up to 7 quick access keys, which are displayed in the bottom bar. On assigning a function to a specific key, a corresponding soft key appears, and it is located in the bottom navigation bar of the main window. It is a so called quick access key, dedicated for most often used functions and processes. 15.3.1. Proximity sensors The balance comprises two proximity sensors enabling wave control of the balance therefore the user does not have to either press any key on the overlay or touch the screen. The program recognizes 4 types of motions performed near the sensor: 1. Placing hand near the left sensor 2. Placing hand near the right sensor 3. Motion to the left 4. Motion to the right CAUTION: using option LEFT MOTION or RIGHT MOTION, it is necessary to remember that parameter must be set to value 500 ms To each of the motions, one of the available options may be assigned: [None; Profile; Adjustment; Zeroing; Tarring; Tare setting; Tare switch off; Reset tare; Packaging; Print; Header printing; Footer printing; Unit; Universal Variable 1; Universal Variable 2; Universal Variable 3; Universal Variable 4; Universal Variable 5; Confirm; Abort; User; Left door; Right door; Open/Close door; Parameters; Product, Warehouse; Client]. - 49 - The selected option is recognized by the program and performed when activated by a particular motion. In order to ensure correct operation the user must remember to set the right sensors sensitivity and the right value for proximity sensors delay (for more information refer to point 33.8 of this manual titled Sensors sensitivity). 15.3.2. Automatically opened door This menu section comprises settings on automatic opening and closing door of a balance featuring such mechanism, i.e. balances MYA 3Y series. The settings may refer to the quick access keys as well as the infrared proximity sensors located on the overlay of balance’s terminal. Settings for a balance MYA 3Y series cover: o Left door / the option enables changing the position of the door on the left side of the weighing chamber o Right door / the option enables changing the position of the door on the left side of the weighing chamber o Open / Close door / the option enables changing the position of the door, e.g. if the weighing chamber is opened, then activating the option causes closing it. If the weighing chamber is closed, then activating the option causes opening the door located on the right side of the weighing chamber. 15.4. Information Information on weighing process is displayed in the grey coloured workspace. It contains maximally 6 pieces of information. If larger amount of data is selected, then only the first 6 are displayed. Each parameter features two options: - YES, information enabled - NO, information disabled 15.5. Printouts Menu printouts comprises two separate sections. The first one is standard printouts, the other one is non-standard printouts. ? Standard printout Comprises three internal sections featuring different variables. For each variable set option YES to include it in a standard printout. If option NO is selected, then the variable is disabled, i.e. it is not printed. PROCEDURE: 1. Press field with name of a template to be edited(Header – Weighing – Footer) and select variables to be printed. 2. If a printout is a non-standard one, - 50 - create it. o HEADER - Dashes - Working mode - Date - Time - Balance type - Balance ID - User - Level status - Client - Warehouse - Product - Packaging - Universal variable 1 … 5 - Empty line - GLP report - Non-standard printout o WEIGHING - N (number of measurements) - Date - Time - Level status - Client - Warehouse - Product - Packaging - Universal variable 1 … 5 - Net - Tare - Gross - Current measurement result - Supplementary weighing unit - Mass - Non-standard printout o FOOTER - Working mode - Date - Time - Balance type - Balance ID - User - Level status - Client - Warehouse - Product - Packaging - Universal variable 1 … 5 - Dashes - Empty line - 51 - - GLP report - Signature - Non-standard printout BASIC PRINCIPLES OF USING PRINTOUTS 1. Press PRINT key on balance’s overlay to print variables that are contained in section WEIGHING of the standard printout, and if they are attributed = YES (see above list of variables in printouts). 2. Variables attributed as YES present in the HEADER and FOOTER are printed ONLY on pressing Print Header and Print Footer soft keys. The soft keys have to be added to the bottom bar of the display, as quick access keys. Adding quick access keys on the bottom bar of the display is described in point 15.3 of this user manual Print data from header Print data from footer Caution: Measuring units for printing mass indication: - Net – main measuring unit (adjustment unit) - Tare – main measuring unit (adjustment unit) - Gross – main measuring unit (adjustment unit) - Current result – currently displayed measuring unit - Supplementary unit – supplementary measuring unit - Mass – main measuring unit (adjustment unit) ? Non-standard printout a printout may contain: TEXTS and VARIABLES(which are acquired from the software on printout). Each non-standard printout is a separate project, featuring specific name, by which it is identified, and saved in the database of printouts. PROCEDURE: 1. Press option , 2. Press key, 3. A window is opened with data such as Name/Code/Project, 4. Set name and code of a printout, 5. Press key, 6. A keyboard is opened on the display for editing the printout, - 52 - 7. Use keyboard to design printout template, the printout may contain texts and variables. Caution: ? User can add a printout by importing configured texts from data storage devices connected to balance’s USB port. ? Printout’s name is ONLY a NAME, and it is not part of its content. ? Means of designing a non-standard printout template is described in point 24.11 of this user manual. 15.6. Profiles Profiles are described in point 14, Profiles, of this user manual. - 53 - 16. PARTS COUNTING Working mode< Parts counting> enables determining quantity of small parts (objects) with equal part mass. Counting is based on determined mass of a single part, which is: o determined from a reference quantity of parts o acquired from database of products o inserted manually as a numeric value Working mode activating procedure • while in the main window, press soft key located in the upper bar of the display, which opens a submenu with selection of available working modes, • select < Parts counting> mode, the software automatically returns to the main window and displays pictogram in the upper bar. The grey coloured workspace contains the following data: o Gross o Standard mass o Low threshold o High threshold o Target value On selecting the parts counting mode, the display contains the following quick access keys in the bottom bar: 1. Setup – access to balance’s menu 2. Print header – print of data declared in the header 3. Print footer – print of data declared in the footer 4. Database of products – selection of products from corresponding database 5. Give mass of 1 part – editing field for inserting mass of a single part 6. Set mass of 1 part – setting mass of a single part from optional number of parts, e.g.: from 10 pcs, 20 pcs, 75 pcs, etc. - 54 - 16.1. Ustawienia dodatkowe zwiazane z liczeniem detali The additional settings enable adjusting the working mode to user’s needs and requirements. To access the setting follow below procedure: Procedure: 1. Press grey coloured workspace, 2. The display indicates menu of: Settings, Keys, Information, Printout and Profile 3. Press key 4. The display indicates functions related to weighing and parts counting modes. Parts counting mode features the following optional functions: - ACAI, Automatic Accuracy Correction: o YES, mass of a single part is updated during counting process o NO, mass of a single part is not updated Means of operation of ACAI function: 1. Number of parts (on adding) on balance’s weighing pan has to be greater than has been previously. 2. Number of parts (on adding) on balance’s weighing pan must be less than twice the amount of which was visible on the display before adding parts. 3. Current quantity of parts must be within the ± 0,3 tolerance of the total value. 4. Measurement result has to be stabilized. - Minimal reference mass: 1unit, 2units, 5units, 10units, it is the minimal mass value of a single part. Unless the condition is met, counting process cannot start. - Result control: o YES, print and save only those measurements which are included within the Lo and Hi thresholds. o NO, all measurements are printed and saved. - 55 - Other functions of menu : - Tare mode - Automatic footer printout - Printout mode / Value release - Printouts Means of using the above functions are given in point 10.8. “Additional parameters on weighing process”. 16.2. Parts counting – quick access keys Each of working modes features a set of default quick access keys, which are automatically displayed on mode activation. The set of keys can be modified by selecting other quick access keys to the bottom bar of the display. Such process requires appropriate operator’s access le. 16.3. Setting standard (reference) mass by inserting determined part mass Procedure: • Press < Give mass of 1 part> key, which opens an editing window with an on-screen keyboard, • Insert value of a single part and accept it by pressing key, the balance returns to working mode < Parts counting> with automatic accuracy correction function enabled. Caution: In case the single part mass is determined as lower than 0,1 of balance’s reading unit, the balance display’s a message: . 16.4. Setting standard (reference) mass by weighing Procedure: • Place a container on balance’s weighing pan and tare its mass, • Press < Set mass of 1 part>, which opens an editing window with an on-screen keyboard, • Insert desired value (number of parts) and accept by pressing key, which displays a command: (where xx – denotes set value of parts), • Load requested number of parts on the weighing pan. On stabilization of measurement result ( pictogram visible on the display) accept the mass by pressing key, • The software automatically recalculates mass of a single part, moves to < parts counting> mode and displays number of parts loaded on the weighing pan with unit (pcs). - 56 - Caution: Remember: • Total mass of all parts loaded on the weighing pan must not exceed the maximal capacity (weighing range) of the balance; • Total mass of all parts loaded on the weighing pan must not be lower than value declared in parameter “Minimal reference mass”. Unless this condition is met, the balance displays a message: ; • Mass of a single part must not be lower than 0,1 of balance’s reading unit. unless this condition is met, the balance displays a message: . 16.5. Acquiring part mass from database A product record in the database of products features set of information which identifies it. One of them is mass, which is used during part counting process. Procedure: When in working mode < Parts counting> press < Products database> key, and then select desired product from displayed list. Insert standard (reference) mass to balance’s memory Procedure for adding standard (reference) mass of a single part to the database of products: a) Press < Setup > key followed by pressing < Database > key b) In the Database of Products press < Products > c) Press name of a product and edit data in field no. [5] Mass d) Return to mode. If there are no data in the database: a) Press < Setup > key followed by pressing < Database > key b) In the Database of Products press < Add > key c) Accept the process of adding a new record in the database d) Fill in field referring to a product, including field no. [5] Mass e) Return to mode. - 57 - 16.6. Updating part mass in the database Determined mass of a single part can be assigned to a product in the database of products. This option is applied while using ACAI (Automatic Accuracy Correction) function in order to determine part mass with high accuracy. Procedure: a) Determine mass of a single part b) Press < Database> key c) Press and hold finger on name of a product, which mass is updated, d) Contextual menu is displayed, e) Select option , reference mass is saved in a product record under entry . 16.7. Parts counting procedure The first step in parts counting mode is obtaining data on mass of a single part. Select one of available options: - Give mass value of a single part (see point 16.3) and place parts on balance’s weighing pan, balance displays totalized parts. - Set mass of a single part from a given quantity of parts (see point 16.4.), the balance additionally shows pictogram of the ACAI function < > (if enabled). Place parts on balance’s weighing pan, the balance displays totalized parts. - Acquire mass of a single part from database of products (see point 16.5.) by selecting a desired product record. Place parts on balance’s weighing pan, the balance displays totalized parts. Caution: All additional elements (i.e. packaging) have to be tarred before starting the parts counting process. - 58 - 16.8. Checkweighing function in parts counting mode Proces liczenia detali moze byc wspomagany funkcja dowazania czyli kontroli czy wskazanie miesci sie pomiedzy progami akceptacji. Checkweighing requires setting values of two thresholds, described as: - LOW threshold [Min= … parts] - HIGH threshold [Max= … parts] and enabling bargraph (set its attribute to YES), which displays below relation: CURRRENT NO. OF PARTS / CHECKWEIGHING THRESHOLDS. Defining the values of Low and High thresholds is carried out in the Database of Products while editing Product entry, or using a quick access key < Defining thresholds>. Procedure • Press grey coloured workspace and press option • Set Bargraph option to YES, return to parts counting mode • Press grey coloured workspace and press option • Assign option to one of the quick access keys displayed in the bottom bar • Return to parts counting mode • Press < Checkweighing thresholds> key and insert values for LOW and HIGH thresholds, return to parts counting mode • Under the measurement result there is bargraph displayed. Colour of the bargraph corresponds to the status of parts counting process. o Yellow bargraph’s colour: current number of parts below set value of Low threshold o Green bargraph’s colour: current number of parts within set value of thresholds o Red bargraph’s colour: current number of parts above set value of High threshold - 59 - 16.9. Dosing function in parts counting mode Parts counting process can be aided by dosing function, i.e. control whether indication does not exceed set target value. Dosing requires setting a value, which is the target, for instance 100 parts, and percent tolerance from the target value. The target value is displayed as a bracket on a bargraph. Defining the value of target mass is carried out using a quick access key < Target Value>. Procedure • Press grey coloured workspace and press option • Set Bargraph option to YES, return to parts counting mode • Press grey coloured workspace and press option • Assign option to one of the quick access keys displayed in the bottom bar • Return to parts counting mode • Press < Target Value > key and insert number of parts recognized as the target value, • If tolerance applies, set its value (range between 0 – 100%) • Under the measurement result there is bargraph displayed, containing: o Current number of parts on the weighing pan (marked with colours – see point 16.7.) o The value of Target Mass (black marker) Caution: The checkweighing and dosing functions can operate simultaneously in the parts counting mode. In such case the dosing tolerance is controlled by Lo and Hi thresholds of the checkweighing function. - 60 - 17. CHECKWEIGHING Working mode< Checkweighing > enables controlling sample mass using two threshold (Low and High). Usually it is accepted, that mass indication is correct if it is included within the thresholds’ values. Working mode activating procedure • While in the main window, press soft key located in the upper bar of the display, which opens a submenu with selection of available working modes, • Select < Checkweighing> mode, the software automatically returns to the main window and displays pictogram in the upper bar. The grey coloured workspace contains the following data: o Supplementary unit o Low threshold o High threshold o Difference – denoting the “distance” of current measurement result from the center of Lo-Hi section. On selecting the checkweighing mode the display contains the following quick access keys in the bottom bar: 1. Setup – access to balance’s menu, 2. Print header – print of data declared in the header, 3. Print footer – print of data declared in the footer, 4. Database of products – selection of products from corresponding database, 5. Set tare – field for setting numeric value of tare, 6. Checkweighing thresholds – for declaring the values of Low and High threshold. - 61 - 17.1. Use of checkweighing thresholds Use of checkweighing thresholds can be carried out by: - Selection of Product < > for which Low and High thresholds have been already set - Inserting the numeric value of thresholds < >, in this case the thresholds are not referred to any product from database PROCEDURE 1 – Selection of product from Database of Products • Press < Database of Products> quick access key • Using list of products select one to be weighed • Automatically, in the grey workspace the values of thresholds are displayed • Under the measurement result there is bargraph displayed. Colour of the bargraph corresponds to the current status of mass: o Yellow bargraph’s colour: mass value below Low threshold o Green bargraph’s colour: mass value within set value of thresholds o Red bargraph’s colour: mass above set value of High threshold PROCEDURE 2 – Manual inserting checkweighing thresholds • Press < Checkweighing thresholds> quick access key • Press Low Threshold key and determine its value • Accept set value by pressing < > key • Press High Threshold key and determine its value • Accept set value by pressing < > key Caution: The value of High threshold has to be bigger than the value of Low threshold. 17.2. Additional settings of checkweighing mode The additional settings enable adjusting the working mode to user’s needs and requirements. To access the setting follow below procedure: Procedure: 1. Press grey coloured workspace, 2. The display indicates menu of: Settings, Keys, Information, Printout and Profile, 3. Press key, 4. The display indicates functions related to checkweighing: - Result control - Tare mode - Automatic footer printout - Printout mode / Value release - Printout Means of using the above functions are given in point 10.8. “Additional parameters on weighing process”. - 62 - 18. DOSING Working mode< Dosing> enables carrying out the sampling process, until obtaining a pre-defined target mass. Working mode activating procedure • while in the main window, press soft key located in the upper bar of the display, which opens a submenu with selection of available working modes, • select < Dosing > mode, the software automat
Most popular related searches