Perma Pure LLC - a Halma Company

RATAmation Brochure

Stay in Complete Control of Your Sampleand Calibration GasesBaldwin™-Series Flow Control Drawers from Perma Pure provide an easy and com-pact solution to control sample and calibration gases. The Model 3300 is a 19” rackmountable integrated gas flow control system for monitoring and controlling gases.Principle of OperationSample gas is extracted from the process through a filter probe and conditioningsystem to remove particulate and moisture. The conditioning system supplies a clean,dry sample to the back panel of the Model 3300 Flow Control Drawer.The stack probe filter and sample pump performance are indicated bythe flow control drawer vacuum/pressure gauges.The standard flow drawer is configured for two gas channels and twocalibration gases, zero and span. Manual control switches are pro-vided for selection of system or direct calibration. Four flow meters areincluded for visual indication and control of calibration gas, individualanalyzer and bypass flow. The Model 3300’s unique block & bleedmanifold system has the ability to switch the sample and up to eight calibration gasesto the analyzer rack utilizing the direct mode or to the total sampling system utilizingthe sample mode.The Model 3300 performs system bias checks. System integrity is verified by compar-ing gas analyzer readings for both the direct and system modes. This easy andefficient procedure identifies problems such as sample transport system leaks oranalyte signal loss.A probe filter blowback relay contact on the flow control drawer facilitates manual orcomputer initiated blowback.• • • • • Manual or PLC control• • • • • Up to 6 gas analyzer channels••••• Up to 8 cal gas channels••••• Block & bleed manifold• • • • • Optional pressure transmitters• • • • • Simple tube connectors• • • • • Pump vacuum gauge••••• Cal gas regulatorFlow ControlDrawersFlow ControlDrawersModel Number 4D-3300 4D-3300PEnclosure 5U (8.75"), 19" rack mount, 18" deep; 24 lbsInput cal-gas channels(max: 8)Sample 5 - 15 psigVacuum 0 - 30" HgCalibration 5 - 35 psigOutput gas channel 0 - 2.5 lpm (max: 6)Blowback Specify 12VDC, line voltage or dry contactElectrical requirements 90-240 VAC, 50/60 Hz; 100 WPressure transmitters n/a Sample, cal gas, sample vacuumBaldwin™-SeriesPERMA PURE LLC8 Executive Drive • P.O. Box 2105 • Toms River, New Jersey 08754(732) 244-0010 • (732) 337-3762 • Fax (732) 244-8140 • www.permapure.com • info@permapure.comModel 3300P back panel terminal connectionsCALIBRATION GASESCAL GASTO PROBELIQUIDDRAINSample Pumpset @ 10 PsigPress. Regulator2 MicronSample FilterPeristalticLiquid Drain PumpThermo-electric CoolerSTACK FLOWCG 1 CG 2 CG 3SAMPLEMANIFOLDV1 V2 V3FI0-2.5 L/MINF2FI0-2.5 L/MINF3F40-2.5 L/MINFIURAW SAMPLEChannel 1Channel 2Channel 3(NOTE: Maximum of 8 Calibration Gases)BALDWIN™-SeriesTankAccumulatorBlowback AirHEAT TRACEFlow Meter0-5.0 L/MINFITOTAL FLOW0-10 L/MINFIV10V9V11GAS BLOCK & BLEED3-WAY SOLENOIDPRESSURESAMPLE/CALIBP2VACCUMPUMPP1SYSTEM CALIBRATION2-WAY SOLENOIDCALIBRATIONSAMPLE/DIRECT3-WAY SOLENOID0-10 L/MINF1FIV4CG 4CONDITIONINGSYSTEMFLOW CONTROL DRAWERChannel 5Channel 4FI0-2.5 L/MINF6F50-2.5 L/MINFIF60-2.5 L/MINFI Channel 6(or Bypass)CG 5V5 V8CG 8CG 7V7V6CG 6FILTER PROBESAMPLEHEATED INSTR AIR @ <90 PSIG-40°F. DEWPOINTCALIBRATION GASSAMPLEOPTIONALVACCUMPRESSURETRANSMITTEROPTIONALSAMPLEPRESSURETRANSMITTEROPTIONALCAL GASPRESSURETRANSMITTERModel 3300 flow schematic capabilitySystem Calibrationor GASS™-Series sample conditioning system
Most popular related searches