Urban Asset Solutions Pty Ltd.

RSF 1000 flyer

??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ?RSF 1000S o l i d P o l l u t a n t F i l t e r??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ?N A T U R A L E C O L O G I C A L S O L U T I O N SThe RSF 1000 before the rain eventPollutants are filtered from the flowBasket is full of pollutants and overflow by-pass is activatedFlow ceases and by-pass flaps return to closed positionK E Y F E A T U R E S Captures more than 95% of gross pollutants > 3mm Collects 49% of total suspended solids No remobilisation of captured pollutants Dry storage of pollutants and no toxic fermentation???? Patented by-pass eliminates the risk of flooding Minimal head/hydraulic loss Principles independently tested at a NATA-approved facility Meets international guidelines and standards???? Capture basket easily removed by small crane truck Base trap door allows easy emptying onto truck tray Easily cleaned by most street-sweeping vehicles Pollutants are not handled during cleaning operation Reduces sedimentation build-up and pipeline maintenance Easy access to pit for maintenance??????Effective Pollutant and Litter RetentionCost-Effective Design and InstallationTested and Proven Fail-Safe Overflow SystemCost-Effective Maintenance Simple design with corrosive-resistant materials Delivered complete as a pre-cast concrete unit Can be retro-fitted into existing pits Manufactured to fit a range of pipe sizes up to 600mm dia. Customised designs to suit site-specific requirements Safe installation procedures minimise public risk??????RSF 1000S o l i d P o l l u t a n t F i l t e rThe Ecosol RSF 1000 Solid Pollutant Filter is designed to remove and retain solid pollutants in stormwater flowson a range of pipelines and consists of a pre-castconcrete pit containing a capture basket and overflow by-pass flaps. The unit is installed either in-line, or at the end of the stormwater line, where there is a drop between the upstream invert and downstream obvert levels of at least 600mm, and preferably more. This drop is needed so that the structure can house an adequately-sized basket.Solid pollutants conveyed in flows from the upstreampipe are filtered through the basket positioneddirectly below the upstream pipe invert.The filtered stormwater then passes throughthe unit to the downstream outlet pipeand into the drainage network without anyhead/hydraulic loss through the unit.As the basket approaches 90% full, the by-pass flaps begin to open in response to the incoming flow. Once the basket is 100% full the pressure of the incoming flow forces open the by-pass flaps, allowingthe excess flow to enter the drainage systemthrough the by-pass openings. This effectivelyeliminates the likelihood of flooding. Even when inby-pass, the captured pollutants are not remobilisedand are retained in the basket.When the flow ceases, the flaps return to their normalposition. In the unlikely event that the springmechanism fails, or debris lodges in the by-pass flaps, they will be in the open position and will not obstruct the flow or cause flooding. The patented overflow by-pass minimises any hydraulic headloss on thedrainage network under a worst-case scenario of fulldesign flow and a full capture basket.The RSF 1000 captures more than 95% of solidpollutants greater than 3mm in size, 60% of solidsgreater than 200µm, and 49% of total suspendedsolids. N A T U R A L E C O L O G I C A L S O L U T I O N SWebsite: www.ecosol.com.au Ecosol Pty Ltd ABN 86 059 012 243 Ecosol (NZ) Wastewater Filtration Systems Ltd (Reg. No AK/1172504) Ecosol (UK) Wastewater Filtration Systems Ltd (Reg. No 4367214) Ecological Filtration Systems Sdn Bhd (Reg. No 651041-U)??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ?P E R F O R M A N C E S P E C I F I C A T I O N S????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????Adelaide+61 8 8212 9733Brisbane+61 7 3368 3966 Melbourne+61 3 9646 3911Sydney+61 2 9669 6000Perth+61 1300 794 654Hobart+61 1300 768 922Auckland+64 9 272 7010 Kuala Lumpur+60 3 7710 6514Townsville+61 7 4728 5711Darwin+61 1300 663 225RSF 1000TFR vs Fill of Basket (based on 1200x1200x600 basket)Fill of BasketTFRRSF 1000By-pass Flow CapacityHead above upstream Invert level (mm)By-pass Flow (m3 /s)RSF 1000TFR vs Fill of Basket (based on 1200x1200x600 basket)Fill of BasketTFRRSF 1000By-pass Flow CapacityHead above upstream Invert level (mm)By-pass Flow (m3 /s)
Most popular related searches