Urban Asset Solutions Pty Ltd.

RSF 4000 flyer

??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ?RSF 4000Solid Pollutant Filter/Oil and Grease ArresterEffective Pollutant and Litter RetentionCaptures more than 98% of solid pollutants > 211µmCaptures 91% of total suspended solidsCollects up to 97% free oils and grease at design flowNo remobilisation or overtopping of captured pollutantsDesigned & managed hydraulics eliminates blockage riskContainment by design - small, medium, or large capacityCost-Effective MaintenanceEasily cleaned by vacuum Easy access to capture silo for cleaning & maintenancePollutants are not handled during cleaningNo risk to public safety and healthMaintenance procedures within OH&S guidelinesDewatering facility removes all solids during cleaningReduced costs as only solids transported to waste facilityTested and Proven Fail-Safe Overflow SystemPatented hydraulically-driven barrierMinimal head/hydraulic lossUnrestricted flow in extreme (flood) conditionsOperates effectively in all flows and gradientsIndependently tested at a NATA-approved facilityMeets international guidelines and standardsCost-Effective Design and InstallationSimple design with no moving partsSafe installation procedures minimise public riskSmall surface footprint with minimal aesthetic impact Lockable lids prevent access by the publicUtilises space already used by the existing stormwater pipeCompact design & shallow depth reduces installation costsMade from durable and corrosive-resistant materialsK E Y F E A T U R E S??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ????????????? ??????????????N A T U R A L E C O L O G I C A L S O L U T I O N S 1,2,3 For more details please refer to the product technical specification available from any Ecosol office or from our websiteSolidPollutantsFree Oil and Grease Water150 to 600mm225 to 900mm300 to 1200mm450 to 1350mm600 to 1650mm750 to 1800mm900 to 2100mm1050 to 2400mm1200 to 2400mm1350 to 2400mm2700 x 1350 x 7503600 x 1650 x 10504500 x 1950 x 13505600 x 2300 x 16506500 x 2600 x 19757450 x 2950 x 23008630 x 3300 x 26259700 x 3700 x 295010680 x 4000 x 325012730 x 4700 x 39000.321.032.434.838.3013.1119.5227.7037.9465.334691,3472,9945,7119,57614,85022,79330,57841,49170,452m3 Litres Litres1,1813,3487,21113,60822,76835,26251,69872,49598,317166,836EcosolUnit CodeUp to 375mm 2200 x 900 x 750 0.23 268 667RSF 4200RSF 4300RSF 4450RSF 4600RSF 4750RSF 4900RSF 41050RSF 41200RSF 41350RSF 41500RSF 41800 Inlet/OutletPipeDiameter1 Range ofTreatable FlowRates (TFRs)2(m3/s)ApproximateExternal Dimensions(LxWxD from Invert)3(mm)HOLDING CAPACITIES Up to 0.051 0.03 - 0.12 0.04 - 0.26 0.13 - 0.47 0.24 - 0.73 0.42 - 1.05 0.66 - 1.43 0.96 - 1.87 1.26 - 2.371.68 - 2.93 2.50 - 4.21The Ecosol RSF 4000 is designed for use in stormwater drains. Incoming flows enter the capture silo and pass through the filtration mesh located below invertlevel on both sides of the silo before entering the cleanchamber and then exiting the unit.The RSF 4000 unit separates, collects, and retains more than 98% of solid pollutants greater than 211µm, 90%of solids greater than 152µm, and 91% of totalsuspended solids. It also collects 30% total phosphorousand 16% total nitrogen. Free oils and grease areretained in the outer channels below invert level by theuse of two vertical baffles.The key to the RSF 4000 success is the design that forces a proportion of the filtered water back upstream along the by-pass channels and against the main directional flow. As this water meets the flows entering the inlet to the capture silo, a unique hydraulically-driven barrier is created, ensuring all flows up to the Treatable Flow Rate (TFR) are directed into the capture silo, thereby enhancingconsiderably the unit’s capture efficiency.As flows of greater magnitude enter the unit, thehydraulic barrier gradually breaks down and in majorpipe discharges, allows the excess flows to by-pass, without remobilising captured pollutants. It is important tonote that the unit continues to collect and filterflows at least equivalent to the TFR, even when the pipeis in full discharge and the unit is in by-pass. Mostother GPTs are unable to operate in this manner.When the capture silo is full, the water cannot pass through the mesh and the hydraulically-driven barrier can no longer be formed. Concurrently, the pollutants form a barrier across the mouth of the filtration unit, directing the incomingwater into the two overflow by-pass channels, therebyeffectively eliminating the risk of flooding. P E R F O R M A N C E S P E C I F I C A T I O N S??????????? ? ??? ? ? ? ? ? ? ? ? ? ? ? ? ?? ? ? ? ? ? ?? ?RSF 4000Solid Pollutant Filter/Oil and Grease ArresterN A T U R A L E C O L O G I C A L S O L U T I O N SWebsite: www.ecosol.com.au Ecosol Pty Ltd ABN 86 059 012 243 Ecosol (NZ) Wastewater Filtration Systems Ltd (Reg. No AK/1172504) Ecosol (UK) Wastewater Filtration Systems Ltd (Reg. No 4367214) Ecological Filtration Systems Sdn Bhd (Reg. No 651041-U)????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????Adelaide+61 8 8212 9733Brisbane+61 7 3368 3966 Melbourne+61 3 9646 3911Sydney+61 2 9669 6000Perth+61 1300 794 654Hobart+61 1300 768 922Auckland+64 9 272 7010 Kuala Lumpur+60 3 7710 6514Townsville+61 7 4728 5711Darwin+61 1300 663 225
Most popular related searches