Thermotron Industries
- Home
- Companies & Suppliers
- Thermotron Industries
- Downloads
- S/SM-8200 Series - Environmental Test ...
S/SM-8200 Series - Environmental Test Chambers Brochure
Thermotron’s S/SM-8200 Series chambers deliver the quality and accuracy you would expect from a premier worldwide supplier of environmental testing equipment. Featuring the 8200 touchscreen programmer/controller, wide temperature and humidity ranges, and multiple chamber sizes, Thermotron’s S/SM-8200 Series chamber is the ideal choice for quality and customizable simulated environmental testing.Ideal for Environmental TestingS/SM-8200 Series Environmental Test ChambersS/SM-8200 SERIES ENVIRONMENTAL TEST CHAMBERS(8, 16, and 32 Cubic Foot Models Shown)Powerful, Yet Versatile ChambersS/SM-8200 Series chambers utilize hermetically sealed compressors that provide moderate temperature change rates while consuming less power than comparable chambers. A heated window provides a clear view of the test area that is illuminated by the interior work space light. Casters provide mobility and easy move-in capabilities. Advanced features such as an electronic humidity sensor and product temperature control add value and reduce test time and maintenance. We understand that protecting your investment is important; that’s why a comprehensive service and support program is available for each S/SM-8200 Series chamber sold. Thermotron’s warranty backs every chamber sold with access to application engineers, technical support, and nationwide field service technicians, lowering the ongoing cost of ownership.8200 Touchscreen ControllerThermotron’s S/SM-8200 Series chambers feature the 8200 programmer/controller. Operation and data collection are easy with its high-resolution 7-inch color touchscreen display. The familiar Windows® look and feel supports robust operations. Its unique main screen allows most of the information and interface to be contained on a single screen, eliminating confusing navigation. The graphing screen uses a tap and drag zoom box, allowing you to magnify specific areas on a graph easily. The built-in USB port allows programs to be interchanged between instruments quickly and easily, as well as allowing the export and transfer of test data using a USB flash drive. With built-in Ethernet capabilities, the 8200 has network-wide accessibility. All of these benefits add up to a powerful series of environmental test chambers that meet the requirements of your test.The 8200 features pinpoint accuracy with touchscreen simplicity.S-8200 Series Standard Features and BenefitsUser-Friendly Pop-Up Keypad for quick and easy data entryInterior Light Illuminates Work SpaceOne access port (standard) Ethernet ConnectionHermetically Sealed CompressorsSelf-Contained Refrigeration System Requires No Cooling WaterElectrical Panel with Disconnect on Front Door for Easy AccessCasters provide mobility and easy chamber move-inHeated Window Provides Clear View, Less CondensationProduct Temperature Control (New)S/SM-8200 Chamber Options• Add'l Access Ports and shelving• Auxiliary Event Relay Board• Cable Notch• CE and CSA Compliant• Chart Recorders• Dry Air or Nitrogen Purge System• GPIB or RS-232/485 Computer Interface• Humidity Water Purification and Recirculation System• Inner Glass Doors• Low Humidity System• Liquid Nitrogen or CO2 Boost/ Back-Up Cooling System• Refrigeration Gauges• ThermAlarm™• ThermoTrak II™ Software• Water-cooling*Specifications subject to change. The addition of accessories may affect performance. Certain options may increase move-in dimensions.Door-Mounted 8200 Programmer Controller Frees Access SpaceUSB PortGraphing Capability† Noise Level: A-weighted sound pressure level measured at a distance of 1.0 meter (39.4 inches) from the surface of the equipment at a height of 1.6 meters (63 inches) from the floor in free-field conditions, using a calibrated instrument. Performance is based upon 60Hz and 23.9°C (75°F) ambient air, and may vary slightly at other ambient temperatures. Chambers are designed for use under normal laboratory operating conditions. For other applications, please consult Thermotron.* Limited by a +7°C (+45°F) minimum dew point temperature and a maximum dry bulb temperature of+88°C (+190°F). Relative humidity indication at or near the physical limits may be affected by sensor accuracy and control tolerance** At a dry bulb temperature above +20°C (+68 °F).*** Based upon temperature uniformity specifications.291 Kollen Park DriveHolland, Michigan, USA 49423Marketing: (616) 393-4580Main: (616) 392-1491Fax: (616) 392-5643E-mail: info@thermotron.comThermotron Industries, U.K.Newton House Winch RoadKent Science ParkSittingbourne, KentME9 8EF EnglandPhone: 01795 436333Fax: 01795 436777Email: sales@thermotron.co.ukwww.thermotron.comSM-8200 SERIES TEMPERATURE/HUMIDITY CHAMBER SPECIFICATIONSModel SM-8-8200 SM-16-8200 SM-27-8200 SM-32-8200Interior Dimensions —WxDxH Inches Centimeters24x24x2461x61x6130x30x3076x76x7636x36x3691x91x9138x38x3897x97x97Cubic Volume — Ft/Liters 8 / 227 16 / 453 27 / 764 32/906Exterior Dimensions — WxDxH Inches Centimeters35x49x7389x124x18545x59x81 114x150x20651x65x88 130x165x22453x68x90 135x173x229Temperature Range -68°C to +180°C (-90°F to +356°F)Temperature Control Tolerance All Models 0.3°C (0.5°F)Temperature Uniformity All Models 0.7°C (1.1°F)Weight — Lbs/Kg 875/397 1,395/633 1,875/851 2,050/930Humidity Range * All Models 10% to 98% RHHumidity Control Tolerance ** All Models 2.5% RHHumidity Uniformity *** All Models 1% RHCompressor Size 1-1 2-2 2-2 2-2 2-3Cooling Change Rates — Min +180° to -65°C (+356°F to -85°F) +71°C to -65°C (+160°F to -85°F) +85°C to -40°C (+185°F to -40°F)72 54 3280 54 3198 64 42106714874 51 23Heating Change Rates — Min -65°C to +180°C (-85°F to +356°F) -65°C to +71°C (-85°F to +160°F) -40°C to +85°C (-40°F to +185°F)43 17 1654 22 2168 28 2673312940 13 11Live Load Capacity — Watts -18°C (0°F) -40°C (-40°F) -54°C (-65°F)550 350 2001,000 700 4001,000 700 4001,0007004001,500 1,050 600Electrical Service — Amps 230/1/60 230/3/60 460/3/60 220/1/50 400/3/50(full load)2519—2711(full load)4633——21(full load)4633——21(full load)4633——21(full load)—5327—24Noise Level† — dBA Heating/Cooling 60/68 60/70 60/70 60/70 60/70S-8200 SERIES TEMPERATURE CHAMBER SPECIFICATIONSModel S-4-8200 S-8-8200 S-16-8200 S-27-8200 S-32-8200Interior Dimensions —WxDxH Inches Centimeters20x20x2051x51x5124x24X2461x61x6130x30x3076x76x7636x36x3691x91x9138x38x3897x97x97Cubic Volume — Ft/Liters 4/113 8/227 16/453 27/764 32/906Exterior Dimensions — WxDxH Inches Centimeters31x42x6879x107x17335x49x73 89x124x18545x59x81 114x150x20651x65x88 130x165x22453x68x90 135x173x229Temperature Range -70°C to +180°C (-94°F to +356°F)Temperature Control Tolerance All Models 0.3°C (0.5°F)Temperature Uniformity All Models 0.7°C (1.1°F)Weight — Lbs/Kg 700/318 800/363 1,320/599 1,800/816 1,975/896Compressor Size 1-1 1-1 2-2 2-2 2-2 2-3Cooling Change Rates — Min +180°C to -65°C (+356°F to -85°F) +71°C to -65°C (+160°F to -85°F) +85°C to -40°C (+185°F to -40°F)50 30 1466 44 2668 50 2885 58 3993654568 48 21Heating Change Rates — Min -65°C to +180°C (-85°F to +356°F) -65°C to +71°C (-85°F to +160°F) -40°C to +85°C (-40°F to +185°F)27 11 1042 16 1552 22 2066 27 2571302838 12 10Live Load Capacity — Watts -18°C (0°F) -40°C (-40°F) -54°C (-65°F)600 400 300550 350 2001,000 700 4001,000 700 4001,0007004001,500 1,050 600Electrical Service — Amps 230/1/60 230/3/60 460/3/60 220/1/50 400/3/50(full load)2721—2512(full load)2519—2411(full load)4633——17(full load)4633——17(full load)4633——17(full load)—4724—24Noise Level† — dBA Heating/Cooling 60/68 60/68 60/70 60/70 60/70 60/70FORM NO. T08-008 10/12 ©THERMOTRON INDUSTRIES PRINTED IN USA
Most popular related searches
