Flowmetrix SA
SAFMAG Beta Meter Data Sheet
07 www.flowmetrix.co.za enquiries@flowmetrix.co.za SAFMAG BETA METER ELECTROMAGNETIC FLOWMETER Industries are increasingly being driven to accurately monitor and control the consumption and disposal of our scarce water resources. The Safmag ß (Beta) Meter is designed for the water, waste water and irrigation industries. The Safmag ß Meter is cost effective easy to use easy to install and provides excellent accuracy and reliable flow measurement in demanding environments. The Safmag ß Meter is available with wetted parts to suit all potable water and effluent applications. The Safmag ß Meter delivers exceptional accuracy of ±0.5% uses the long proven non-intrusive principle of electro-magnetic induction has no moving parts and introduces zero head loss. Readings are independent of density, temperature, viscosity and pressure. The ß signal converter has state-of-the-art electronic components and a high-speed microprocessor for accuracy and reliability. The Safmag is a South African designed and manufactured flow meter with a long history of delivering accurate and reliable flow measurement with exceptional local product support. Water & Waste Water are becoming increasingly expensive. When you need to know how much how fast where and when the water went the ß Meter is the natural choice. Flow total and flow rate are always available at the converter. Output signals available to remote instrumentation and telemetry include analogue and digital outputs and Modbus RTU RS485. PRODUCT FEATURES: Sensor size DN10..150 W PN 16 IP67, IP68 (optional) DN150..600 MXI PN 10/16 IP67, IP68 (optional) Transmitter Beta remote wall mount IP67 Display Two-line rate and total. Displayed total selectable resettable/grand total Configuration Supplied to customers spec or modified on site via easy to use menu structure with touch keypad Outputs Isolated open collector pulse x 3 24V auxiliary power supply Isolated active 4-20mA programmable Communication Modbus RTU RS485 (optional) Power supply 80-240Vac 50/60Hz <5VA 12-30Vdc <5W Accuracy +/- 0,5% of flow rate >0.5m/s Repeatability +/- 0,1% of flow rate >0.5m/s Range 0.1-10m/s Calibration Standard 3-Point calibration certificate Features Batching control with OCT output Low Cost Non-intrusive No pressure loss No moving parts No maintenance Active empty pipe detection Integral spike suppression Password and tamper protection Error displays for easy diagnostics Easy to install Options GSM telemetry - Installation Kit (Bolt sets & gaskets) - Grounding rings (for lined or non-conductive pipe) Standards ISO 6817 First Edition 1992-12-01 Magflow design, CE Certified, IEC 60068-2-6 Vibration, IEC-60068-2-27 Shock FLOWMETRIX MENU SAVE W SENSOR L1 D1 L2 MXI SENSOR W SENSOR DATA TABLE Operating Flowrate m3/hr Meter Size, ID (mm) L1 (mm) L2 (mm) D1* (mm) Mass (Kg) Min** Max 10 80 174 64 1.4 0.14 2.8 15 80 174 64 1.4 0.32 6.4 25 80 174 64 1.4 0.88 17 40 90 195 85 1.9 2.25 45 50 100 212 102 2.5 3.5 70 80 125 237 127 3.5 9 180 100 150 270 160 5.3 14.5 280 150 200 328 218 15 32.5 640 · D1 Fits between flange bolts for SABS 1123 1600, BS4505 PN16, BS10 · T/D, ANSI 150# ** Minimum flowrate at which stated best accuracy applies L1 L2 MXI SENSOR DATA TABLE Operating Flowrate m3/hr Operating Flowrate m3/hr Meter Size, ID mm L1 mm L2 mm D1 mm Mass kg Min** Max Meter Size, ID (mm) L1 (mm) L2 (mm) D1 (mm) Mass (Kg) Min** Max 150 300 355 315 42 32 640 400 600 645 605 190 226 4520 200 350 415 375 60 56 1130 450 650 705 665 220 286 5720 250 450 470 430 80 88 1760 500 700 775 735 280 354 7070 300 500 525 485 100 127 2540 600 800 890 850 420 509 10180 350 550 585 545 140 173 3460 ** Minimum flowrate at which stated best accuracy applies ß Signal Converter 125(l) x 125(w) x 75(d) D1 www.flowmetrix.co.za enquiries@flowmetrix.co.za 06 SAMPLE CODE SAFMAG 150 D 2 HD SS R 010 W SIZE 010 10mm W 015 15mm W 025 25mm W 040 40mm W, MXI 050 50mm W, MXI 080 80mm W, MXI 100 100mm W, MXI 150 150mm W, MXI 200 200mm MXI 250 250mm MXI 300 300mm MXI 350 350mm MXI 400 400mm MXI 450 450mm MXI 500 500mm MXI 600 600mm MXI SIGNAL CONVERTER B BETA Converter D DCMPU Converter SUPPLY VOLTAGE 1 115Vac 50/60Hz 2 230Vac 50/60Hz 3 10-30Vdc 4 80-240Vac 50/60Hz LINING MATERIAL PT PTFE -10 to 80°C (W) HD HDPE -10 to 60°C (W Sensors) NR Natural rubber -10 to 70°C (MXI Sensors) DA Durathane rubber -10 to 70°C (MXI Sensors) OTHER (consult factory) ELECTRODE MATERIAL SS 316 Stainless steel HC Hastelloy C OTHER (consult factory) CONVERTER MOUNTING R Remote wall mount CABLE LENGTH 010 Length in metres (max 100m) FLANGE PATTERN 1 SABS 1123 1000/3 - 10 bar (MXI Sensor DN150..600) 2 SABS 1123 1600/3 - 16 bar (MXI Sensor DN150..600) 5 SABS 1123 2500/3 - 25 bar (MXI Sensor DN150..600) 6 SABS 1123 4000/3 - 40 bar (MXI Sensor DN150..600) W Wafer format – no flanges, 16 bar maximum (W Sensor DN25..150) Fits between flange bolts for SABS 1123 1600, BS4505 PN16, BS10 T/D, ANSI 150# OTHER (consult factory) SAFMAG MODEL NO. www.flowmetrix.co.za enquiries@flowmetrix.co.za
Most popular related searches