Scientech, Inc., a Division of Curtiss-Wright
- Home
- Companies & Suppliers
- Scientech, Inc., a Division of ...
- Downloads
- Scientech - OCA801 - One Channel ...
Scientech - OCA801 - One Channel Isolator Brochure
NUSI 800 Series One Channel Isolator Scientech NUSI Products are manufactured by Scientech, C16 a business unit of Curtiss-Wright Flow Control Company. The OCA801 One Channel Isolator replaces the obsolete Hagan 7100 single channel isolator, and has the following functions: ? Electrically isolates an input signal from faults at the output or on the power line, to prevent output-side problems from affecting safety-related inputs. ? Acts as a signal buffer (repeater) that enables more connections to the output. ? Performs voltage-to-current signal conversion. OCA801 OCA800 OCA801 SPECIFICATIONS Power Supply Voltage: 120 V ac RMS ( ± 10 %), 60 Hz ( ± 5 %) Power Consumption: 2 W typical, 3 W, 50 VA maximum inrush Accuracy: ± 0.1 % of output full scale, repeatable to 0.05 % Linearity: Better than ± 0.05 % of output full scale Dielectric Withstand: 3000 V dc and 1000 V ac (RMS) from input to output 1000 V dc and 1000 V ac (RMS) from input to case Credible Live Fault: 480 V ac, 140 V dc at 20 A Surge Withstand: Using the waveform described in IEEE-472-1974 Temperature Effects: Less than 0.50 % change of output full scale per 50 °F change in temperature for overall module gains less than 1.7; otherwise, less than 0.05 % of output full scale change for 1 °C change in temperature Electrical Qualification: Plant protection, qualified to IEEE 323-1974/1983 and IEEE 344-1975/1987 Ambient Temperature: 35 °F to 122 °F (2 °C to 50 °C) (normal operation) 122 °F to 135 °F (50 °C to 57 °C) (abnormal operation for 200 hours) -40 °F to 185 °F (-40 °C to 85°C) (storage) Relative Humidity: 0% RH to 95 % RH, non-condensing Pressure: Atmospheric Radiation Limits: 104 rad TID gamma over forty yearsNUSI 800 Series One Channel Isolator Scientech 208.524.9200 fax: 208.524.9238 www.scientech.cwfc.com C17 HOW TO ORDER The model number and configuration typically should be specified as follows: Example: OCA801-05-07-08 POWER SOURCE:See table 3OUTPUT RANGE:See table 2OCA80xINPUT RANGE:See table 1C2 C3- -C1 - Table 1 – Input Range Table 2 – Output Range Code Input Range Impedance ? Code Output Range Impedance ?00 Not Loaded 00 Not Loaded 01 0 to 100 mV dc 100 M 01 0 to 100 mV dc 32.9 02 0 to 51 mV dc 100 M 02 0 to 51 mV dc 17.3 03 0 to 1 V dc 100 M 03 0 to 1 V dc 299 04 0 to 5 V dc 100 M 04 0 to 5 V dc 825 05 1 to 5 V dc 5.2 M 05 1 to 5 V dc 825 06 0 to 10 V dc 400 k 06 0 to 10 V dc 1000 07 4 to 20 mA dc 249 07 4 to 20 mA dc 1050 * 08 10 to 50 mA dc 100 08 10 to 50 mA dc 600 * 09 0 to 1 mA dc 50 09 0 to 180 mA dc 59.3 10 0 to 132 V ac 3.4 M 10 0 to 3.5 V ac 825 11 0 to 20 mA dc 249 11 0 to 20 mA dc 1050 * 12 0 to 50 mA dc 100 12 0 to 50 mA dc 600 * 13 50 to 10 mA dc 100 13 1 to 5 V dc 249 14 Variable 1 M 14 10 to 44.29 mA dc 660 * 15 0 to 8 V dc 428 k 15 N/A 16 -10 to 10 V dc 3.7 M 16 0 to 1 mA dc 30 k * 17 -2 to 15 V dc 2.4 M 17 4 to 22.49 mA dc 1050 * 18 5 to 1 V dc 100 M 18 10 to 56.22 mA dc 550 * 19 3.6 to 11.6 V dc 477 k 20 2 to 10 V dc 427 k 21 -2 to 2 V dc 3.5 M 22 -20 to 20 mA dc 249 23 N/A Table 3 – Power Source 24 1 to 2 V dc 3.2 M Code Power25 0 to 4 V dc 100 M 00 Not Loaded 26 10 to 32.4 mA dc 200 01 ± 15 ± 1 V dc 27 4 to 10 mA dc 475 02 28 ± 2 V dc 28 0 to 10 V (Hi – Z) 1013 03 5 ± 0.25 V dc 29 0 to 120 V dc 2.5 M 04 12 ± 1 V dc 30 Group 1 Selectable Varies 05 15 ± 1 V dc 31 2, 4 or 10 V dc Varies 06 24 ± 2 V dc 32 0 to 2 V dc 100 M 07 48 ± 2 V dc 33 0 to 3.45 V dc 100 M 08 85 to 132 V ac, 125 V dc 34 1.08 to 5.4 V dc 5.2 M * These are not output impedances; these are the output drive capabilities of the current output models. Scientech is the premier provider of custom solutions for obsolete analog and digital nuclear power plant instrumentation.
Most popular related searches
