Sirco Controls Limited
- Home
- Companies & Suppliers
- Sirco Controls Limited
- Downloads
- Sirco Series 2000 Medium Pressure Range ...
Sirco Series 2000 Medium Pressure Range Brochure
MEDIUM PRESSURE RANGE – SERIES 2000 - 1 - Leaflet 12/10 MODELS: 2001 Single Switch, Differential Non Adjustable 201 Single Switch, Differential Adjustable 2002 Two Switch, Differential Non Adjustable 202 Two Switch, Differential Adjustable on 1st Switch Only All models are available as either Pressure or Vacuum sensitive switches and cover the range -1 to +210 Barg in a group of 12 basic models. Controls can be supplied with varying degrees of protection, and with various approvals for use in Explosion proof/Flameproof areas. (Refer to list for options). More detailed information on these approvals can be found in the relevant sections of this catalogue. Models falling within the range 0 to 1 Barg can be supplied as Vacuum switches (see code guide). Materials used in the manufacture of sensing units and pressure chambers are according to customer requirements and operational application. All switches are fitted with a mounting bracket as Standard (except Flanged Controls). All switches are available with internal or external set point adjustment (External Adjustment is Standard). For accuracy class and zone refer to leaflet 03/09. PRESSURE AND VACUUM OPERATED CONTROLS OPERATING RANGE DIFFERENTIAL BASIC MODEL CODE PROOF MAX WORKING NON ADJUSTABLE RANGE SERIES PRESSURE PRESSURE CODE CODE -1 to +5 Barg 0.1 or 0.2 Bar 00 – 2001W – AO† 7.5 Barg 5.8 Barg -112 to +112 mbarg 7.5 or 15 mbar 00A – 2001W – AO† 7.5 Barg 5.8 Barg 20 to 200 mbarg 7.5 or 15 mbar 2 – 2001W – AO† 10.5 Barg 8.07 Barg 0.1 to 0.5 Barg 0.02 or 0.04 Bar 3 – 2001W – AO† 10.5 Barg 8.07 Barg 0.14 to 1.4 Barg 0.02 or 0.04 Bar 3A – 2001W – AO† 10.5 Barg 8.07 Barg 0.14 to 4.2 Barg 0.04 or 0.07 Bar 4 – 2001W – AO† 10.5 Barg 8.07 Barg 0.35 to 7 Barg 0.05 or 0.1 Bar 5 – 2001W – AO† 10.5 Barg 8.07 Barg 1.4 to 14 Barg 0.1 or 0.2 Bar 6 – 2001W – SO†† 52.5 Barg 40.38 Barg 2.1 to 21 Barg 0.15 or 0.35 Bar 7 – 2001W – SO†† 52.5 Barg 40.38 Barg 3.5 to 35 Barg 0.35 or 0.7 Bar 7A – 2001W – SO†† 52.5 Barg 40.38 Barg 7 to 100 Barg 3 or 6 Bar 8 – 2001W – ST††† 250 Barg 192 Barg 70 to 175 Barg 5 or 10 Bar 9 – 2001W – ST††† 250 Barg 192 Barg ___________________________________________________________________________________________________________________________________________________________________________________ DIFFERENTIAL ADJUSTABLE -1 to +5 Barg 0.2 to 1.7 Barg 00 – 201W – AO† 7.5 Barg 5.8 Barg -112 to +112 mbarg 15 to 63 mbarg 00A – 201W – AO† 7.5 Barg 5.8 Barg 20 to 200 mbarg 15 to 60 mbarg 2 – 201W – AO† 10.5 Barg 8.07 Barg 0.1 to 0.5 Barg 0.04 to 0.21 Barg 3 – 201W – AO† 10.5 Barg 8.07 Barg 0.14 to 1.4 Barg 0.04 to 0.4 Barg 3A – 201W – AO† 10.5 Barg 8.07 Barg 0.14 to 4.2 Barg 0.07 to 0.7 Barg 4 – 201W – AO† 10.5 Barg 8.07 Barg 0.35 to 7 Barg 0.1 to 2.1 Barg 5 – 201W – AO† 10.5 Barg 8.07 Barg 1.4 to 14 Barg 0.2 to 3.5 Barg 6 – 201W – SO†† 52.5 Barg 40.38 Barg 2.1 to 21 Barg 0.35 to 6.3 Barg 7 – 201W – SO†† 52.5 Barg 40.38 Barg 3.5 to 35 Barg 0.7 to 10.5 Barg 7A – 201W – SO†† 52.5 Barg 40.38 Barg Standard switches contain one single pole double throw microswitch. Standard electrical rating 15 amps 400 vac. Standard electrical entry M20 x 1.5 Int. through 360°. †Standard construction Aluminium Pressure Chamber and Nitrile Rubber Diaphragm (M.W.T. 90° C) = AO. ††Standard construction Stainless Steel Pressure Chamber and Nitrile Rubber Diaphragm (M.W.T. 90° C) = SO. †††Standard construction Stainless Steel Pressure Chamber and Stainless Steel Diaphragm (M.W.T. 200° C) = ST. ††(Aluminium Pressure Chambers are not available on these models.) †††(Aluminium Pressure Chambers and Fabric Diaphragms are not available on these models.) For construction other than above refer to the 2nd page of this leaflet for options, and change code accordingly. Terminal box, exp/flameproof enclosure, pneumatic valve fitted to surface ‘A’ *This dimension is 242 for ‘00’ and ‘00A’ ranges, it will also differ for vacuum models and safety vented models. Higher Proof Pressures Available. Consult Factory. Re-calibration of Operating Range may be required if Maximum Working Pressure exceeds 20% above the top of the Operating Range. Proof Pressures over 21 Bar will have High Tensile Steel Grade 12.9 Screws, Plated. Proof Pressures up to 21 Bar will have Stainless Steel Screws Grade A2/A4. - 2 - Leaflet 12/10 CODE DEGREE OF WEATHERPROOF W PROTECTION IP55 IP55 IP66 IP66 ELECTRICAL IITEM 1 ATEX approved for Zone 2 areas E(d) All ranges will have 2 x the larger of the OUTPUTS EN 50021:1999, EN 60079-0:2009, EN 60079-15:2005 two Non-Adjustable Differentials listed. ll 3 G EExn AC llC T6 (Tamb = -20ºC to +60ºC) Certificate Numbers: Baseefa03ATEX0319X Baseefa03ATEX0319X/1 FOR HAZARDOUS AREAS IITEM 2 ATEX approved for Zone 1 areas H(A – K) EN 50014: 1997 + amd. 1 & 2 t EN 50018:2000, EN 60079-0:2009, EN 60079-1:2007 ll 2 G EEx d llB + H2 (Tamb = -20ºC to +60ºC) Certificate Number: Baseefa02ATEX0025X (single switch) Certificate Number: Baseefa02ATEX0026X (two/twin switch) ITEM 3 Intrinsic Safety. Gold Contact Microswitch WIS All ranges will have 1.5 x the larger of the classed as ‘Simple Electrical Apparatus’ two Non-Adjustable Differentials listed. and may be used without certification in a barrier circuit. (BS EN 50020: 2002, BS EN 60079-14: 1997 Para 3.21) S.P.D.T. Prefix Range Code with ‘X’ ALTERNATIVES HIGH LOAD 10 amp, 125 vac/vdc and state ratings. TWO SWITCH Max. Setting Span = 30% of the Range Span 2002 MODELS Adjustable Differential is not available on (ELECTRICAL second switch. 202 OUTPUT) TWIN SWITCH Twin Microswitches for simultaneous action TW Differential x 2 MODELS (ELECTRICAL OUTPUT) PNEUMATIC Poppet 3 port SMS All ranges will have 2 x the larger of the VALVE SWITCHES Prefix Range Code: two Non-Adjustable Differentials listed. Pilot Operated 3 port PV Differential will be 4 x the larger listed. PRESSURE Stainless Steel S CHAMBER Phosphor Bronze Z MATERIAL P.T.F.E. X Trovidor (P.V.D.F.) J Phosphor Bronze Z Hastelloy Hast. Titanium Tit. Incoloy I Monel M If P.T.F.E. lining is required for Pressure Chambers add - X after Pressure Chamber material Other material available on request. Consult Factory DIAPHRAGM Stainless Steel (Differential x 2) T Not available on 00 or 00A Range MATERIAL P.T.F.E. X Viton (Differential x 1½) V Monel (Differential x 2) M Not available on 00 or 00A Range Tantalum (Differential x 2) TANT Not available on 00 or 00A Range SAFETY VENTED CONSTRUCTION Prefix Range Code with: G FLANGES Available on all models. Prefix Series Code with: F FOR VACUUM SERVICE Prefix Series Code with: V PROCESS ¼” B.S.P. Female standard (Rp¼) Alternatives available up to ½” CONNECTIONS ¼” Flushout Prefix Pressure Chamber Material code with: F MANUAL RESET Available on all Electrical & Pneumatic 2001/201 Series, MRR (Reset on Rising Pressure) (RISING or FALLING) except Explosion proof/Flameproof Models. MRF (Reset on Falling Pressure) H(A)= BZ-2R H(B)= BZ-R H(C)= BZ-2R-722 H(D)= 91-SE1 H(F)= 91-SE1-3N55 H(G)= 1HM1 H(H)= 3HM1 H(I)= MT-4R H(J)= BM-2R H(K)= BM-1R Differentials Listed over and Electrical Ratings will vary depending on Microswitch Fitted. See Leaflet 12/02 for Details
Most popular related searches
