Burke Water Systems Manufacturing Inc.

Sprinkler & Pool Regular Flow High Pressure Pump- Brochure

2190 Boul. Dagenais West TEL: 514.337.4415LAVAL (QUEBEC) FAX: 514.337.4029CANADAH7L 5X9 info@burcam.comINSTALLATIONINSTRUCTIONSMODELS506120S506220S503120S503220S506530SSNSPRINKLERPUMPSPlease read these instructionscarefully. Failureto comply toinstructionsand designedoperation of this system,may voidthewarranty.Your pump has been carefully packaged at the factory toprevent damage during shipping. However, occasional damage may occur due to rough handling. Carefullyinspect your pump for damages that could cause failures.Report any damage to your carrier or your point of purchase.ILLUSTRATED MODEL506120SWWW.BURCAM.COMFactory set voltage 115 VConnection voltage changing:Before changing the voltage connection:A) Ensure the power to the pump is disconnected.B) Open motor junction box cover.C) Please select the up knob position for 115 Vor down knob position for 230 V.orPull voltage selector knob 1/4” and align arrow with desired connection voltage. D) Push back in voltage selector knob.E) Close motor junction box.© 2011 BUR-CAM Printed in Canada 506200INSTALLATIONINSTRUCTIONSMODELS506120S506220S503120S503220S506530SSW506530SSNSPRINKLERPUMPSPlease readthese instructionscarefully. Failureto comply toinstructionsand designedoperation ofthis system,may voidthe warranty.SAFETY INSTRUCTIONS:This fine pump that you have just purchased is designed from the latest in material and workmanship.Before installation and operation, we recommend the following procedures:CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TOENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVEBEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLYWITH THEM.WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOMEELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH AFUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUNDFAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALLWIRING.THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVERBE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PRO-TECTION.NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE ORPRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREWTHE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROMTHE RECEPTACLE.ABCDMaterial required for drilled well application (indoor use only)Shallow well pump installationR?Desired length of polyethylene 1” pipe, 100 PSI, CSA or UL approved, to link up from pumping level to pump.R?1 1” foot valve (750756 or 750752P).R?1 well seal, as per well casing diameter (750929 6” x 1”).R?1 1” well seal elbow (750860).R?2 1” male adaptors (750865 or 750871).R?8 1” stainless steel clamps (750885).R?Teflon tape.2ToolsScrewdrivers, hacksaw to cut pipe, knife to assist in pipecutting, round file to smooth pipe ends, pipe wrench,adjustable wrench to tighten fittings, propane torch andwelding material.VOLTAGE SELECTION SWITCHmodels since 20061. POWER off2. Please SELECT the up knob position for 115 V or down knob position for 230 V.3. PUSH plug in to desired voltage.VOLTAGE SELECTION SWITCH2005 and older1. POWER off2. PULL selector plug out3. ROTATE plug to align arrow todesired voltage4. PUSH plug in to desired voltage.3APPLICATIONR?This pump is designed for shallow wellinstallation for water level up to 25 feet. R?Capacity:Suction 506120S 506220S 503120S 503220S 506530SSN5’ 715 800 710 754 897 US GPH10’ 630 690 622 659 749 US GPH15’ 575 625 548 581 638 US GPH20’ 500 545 474 502 555 US GPH25’ 450 480 437 463 472 US GPHINSTALLATION STEPSWe recommend that you install your pump in a clean and dry location wherethere is adequate room for servicing at a later date. Protection from freezingtemperatures and good ventilation should be considered as well, to provide thepump an environment for long life. Locating the pump as close as possible tothe water source will reduce friction losses encountered in the suction pipe.Friction losses in the suction pipe must be taken into consideration when thehorizontal offset is greater than 50 feet. The suction pipes should be increasedfrom 1” to 1 1/4”. This will reduce friction losses and allow the pump to give max-imum performance.A new well should be checked to determine that it is free from sand. Sand willdamage the seal and the impeller. Have your well driller clean the well beforeyour installation.Never run the pump dry. Damage to the seal may occur. Fill pump body andsuction pipe with water before turning on the power.THE RUN OF HORIZONTAL PIPE FROM THE TOP OFYOUR WELL INTO THE HOUSE, WHERE YOUR PUMPWILL BE LOCATED, MUST BE INSTALLED IN A TRENCH,BELOW THE FROST LEVEL OF YOUR AREA.STEP 1FRICTION LOSS INPIPE NOT INCLUDEDFEATURESR?Specially treated cast iron pump body or stainless steel. Easy to prime R?Totally enclosed, fan cooled motor,bearing to bearing. Built for a continuous use.R?Full time connected run capacitor, to eliminatestarting wear vs regular motor.R?Thermal and overload protection.R?Noryl impeller, built-in injectorR?1/2HP, 115VAC, 60Hz, 8A, (16A when start).3/4HP, 115VAC, 60Hz, 9A, (18A when start).4Cut the desired length of poly pipe to run from the top of the well to the pumping level.Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside ofpipe. This may block pump injector or impeller).Tape male adaptor threads with teflon tape and thread adaptor into the foot valve.Slide 2 stainless steel clamps over one end of pipe and use torch to soften pipe. Insert themale adaptor and foot valve into this pipe end. Tighten clamps with screwdriver when cool.For security against leaks, we suggest to install 2 stainless steel clamps on each adaptor.Insert the well seal elbow thru the opening of the seal.Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipewith your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal).Tighten clamps with screwdriver when cool.Install the well seal and piping assembly into your well casing. Tight down the well seal boltsusing your adjustable wrench.Install your pump in the house, on a sound foundation, as close as possible to the watersource. Locate and screw your injector body to your pump body. Locate the suction inlet inthe front of the injector. Thread an adaptor into inlet using teflon tape. Do not over tighten.Cut the desired length of pipe from pump location to the well seal and connect both endsusing the previous way, with stainless steel clamps and torch.Do not fill in your trench to the house until you have checked for any leaks in yourconnections or trouble in your water system.Sand or well points are limited to areas where water bearing sand or gravel lies below thesurface, and where there are no boulders or rocks to interfere with the driving into the groundof the point.The amount of water any “one” well point will supply is usually rather limited. Sometimes, itis necessary to use more than one point to increase the supply of water, entering to thepump’s suction.THE IMPORTANT INSTALLATION STEP IN USING WELL POINTS IS THAT A CHECKVALVE MUST BE USED IN THE SUCTION PIPE LEADING TO THE SUCTION INLET, ASCLOSE TO THE PUMP AS POSSIBLE, TO KEEP SUCTION LINE AND PUMP WELLPRIMED.Do not use an extension cord to connect your pump to the power source. From your distribution panel to the pressure switch, we recommend a wire gauge not smaller than 14 gauge.STEP 5STEP 3STEP 4STEP 6STEP 7for sandor wellpointsSTEP 2SHALLOW WELL APPLICATIONSEE DIAGRAM ON PAGE 5To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well capinstead of an elbow and a well seal as describe in steps 3 and 4.STEP 85SHALLOW WELL APPLICATIONSTEP 2 Cut poly pipeand install the check valve.STEP 3 Insert wellseal elbow thru the seal andattach to pipe.STEP 4 Install wellseal and piping into well casing.STEP 5 Install your pumpand thread an adaptor into inlet.STEP 6 Cut polypipe and connect both ends.Check valve,close to pump.Well point optionnal installationSTEP 7 You may install one or moresand points to increase the supply of water.REPAIR PARTSRepair parts may be ordered from your authorized point of sale or fromBUR-CAM PUMPS38393735302936153231323134333414139641617715188192223252627282120REF PARTS DESCRIPTIONS1 506391 Cast iron pump body2 750769 Pressure gauge3 52319 1/4”NPT 1/8”barb brass adaptor4 506389 Nozzle5 750748 Plastic tubing6 506052 Nozzle O-ring7 506380 Venturi 8 506388 Venturi O-rings (2) 9 506387 Diffuser10 506055 Impeller brass nut11 506381 Gasket12 506056P Noryl impeller 13 506382 Snap Ring 14 506057 Mechanical shaft seal15 350129 Pump body O-ring 16 506059GP Stainless steel seal plate 17 506060 Sand slinger18 506062 Body cap screw19 506061GP Pump bracket 20 506383 Motor flange cap screw21 506074GP Fan coverREF PARTS DESCRIPTIONS22 506073GP Motor fan23 506072GP Motor end bell24 506385 Wave spring washer25 350335 Motor bearing fan side 26 506070GP Rotor/shaft 27 506069 Rotor shaft key 28 350335 Motor bearing pump side29 750957S Pressure switch30 506075 Motor/pump foot 31 506300 Priming plugs (2) 32 506400 Priming plug washers (2)33 506067GP2VStator winding 34 506386 Grounding screw35 506065 Capacitor junction block 36 506094 115/230V selector37 506064 Motor capacitor 38 506014 Cover box junction 39 506384 Cover box screw40 506601 Handle for spinkler model41 52257 Reducer 1’’ to garden hose.506120S 20071012112464041REPAIR PARTSRepair parts may be ordered from your authorized point of sale or fromBUR-CAM PUMPS506220S 2002REF. PART DESCRIPTION1 506400 Washer2 506300 Drain and/or priming plug3 506402 Pump body4 506051 Nozzle5 506052 Nozzle O-ring6 506053 Venturi O-ring7 506406 Venturi8 506053 O-ring9 506317 Diffuser10 506022 Impeller nut11 506292P Impeller12 506411 Snap ring13 506288 Pump body O-ring14 506309 Mechanical seal15 506287 Seal plate16 506415 Screws (3)17 506416 Sand slinger18 506289 Pump bracket19 506297 Body cap bolts (4)20 506419 Box cover screw21 506014OS Junction box coverREF. PART DESCRIPTION21 506014 Junction box cover22 506065OS Junction box22 506065 Junction box23 506030GP Stator24 506015 Capacitor25 506031 Pump side bearing26 506318 Shaft key impeller27 506314GP Rotor28 506032 Fan side bearing29 506428 Wavy washer30 506296 Motor end bracket31 506430 Screws (3)32 506017 Fan33 506016 Fan cover34 506094 115/230V selector (since 2006)34 506093 115/230V selector (2004-2005)34 506093IOS115/230V selector (before 2004)35 506312 Motor/pump foot36 506601 Handle for spinkler model37 52257 Reducer 1” NPT to garden hose38 52212 Brass plug73332313020212233824233529282726252910111213141615567343618171914837REPAIR PARTSRepair parts may be ordered from your authorized point of sale or fromBUR-CAM PUMPS819503120S-503220S 2011REF. PARTS DESCRIPTION1 510054 Motor 1/2HP1 510054-2 Motor 3/4HP2 510055 Motor screws (4)3 750957S Pressure switch4 510056 1/4’’NPT 1/4’’ Barb elbow5 750748 Hose6 510053 Seal plate O-ring7 510052 Mechanical seal8 510048 Impeller9 510047 Diffuseur10 510065 Diffuseur plateREF. PARTS DESCRIPTION11 510051 Diffuseur plate O-ring12 510050 Diffuseur plate washers (3)13 510049 Diffuseur plate screws (3)14 510069 Venturi15 510046 Nozzle16 510056 1/4’’ NPT 1/4’’ Barb elbow17 510045 Cast iron pump body18 750769 Pressure gauge (not shown)19 506601 Handle for springkler model20 52257 Reducer 1’’ NPT to garden hose20REPAIR PARTSREF. PARTS DESCRIPTION 1 506101 Stainless steel pump body 2 506052S Nozzle O-ring 3 506042S Venturi 4 506053S Venturi O-ring 5 506085 Diffuser 6 506055 Impeller nut 7 506083 Impeller 8 506057 Mechanical seal 9 506084 Pump body O-ring10 506095 Seal plate11 506060 Sand slinger12 506103 Pump bracket13 506105 Pump body screws (8)14 506014OS Junction box cover14 506014 Junction box cover15 506064 Capacitor16 506065OS Capacitor junction box16 506065 Capacitor junction box17 506097 Stator18 350335 Bearing pump side19 506098 Shaft key20 506099 Rotor shaft21 350335 Bearing fan side22 506100 Motor end bell23 506073GP Motor Fan24 506074GP Fan cover25 506104 Motor / pump foot26 506076 Drain / priming plug27 506094 115/230V selector28 506419 Cover screws33 506601 Handle for sprinkler model (Not shown)34 52257 Reducer 1’’ NPT to garden hoseREF. PARTS DESCRIPTION 1 510000 Pump body 2 510001 Priming / drainage plug 3 750769 Pressure gauge 4 510003 Pump body screw (6) 5 510004 Venturi O-ring 6 510005 Venturi / diffuser 7 510006 Impeller 8 510007 Washer 9 510008 Mechanical seal10 510009 Seal plate O-ring11 510010 Seal plate12 510011 Water slinger13 510012 Motor14 510013 Capacitor15 510014 Junction box cover51 510022 Base plate52 510023 Base plate bolts (2)53 510024 Base plate washers (4)54 510025 Base plate nuts (2)55 510026 Nut56 510027 Handle57 510028 Washer58 510029 Bolt59 510030 Handle cover60 510031 Power cable61 510037 Capacitor holder506530SSN 2007 506530SSW13212 34 56 7 8 1113910121455 58 57 56 591561605453515224232218172519202126135246781211109271628 151434Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS10TROUBLE SHOOTING GUIDE CHECKLISTNEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWERCONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWERFROM THE RECEPTACLE.Switch is off positionBlown fuseTripped breakerDirty pressure switchDefective pressure switchDefective motorPump not primedLeaky suction lineFoot valve pluggedEjector nozzle cloggedWater level below foot valveSuction lift to greatImproper voltageWater level below foot valveEjector nozzle cloggedExcessive friction in pipeImproper voltageLeaky suction lineGaz in waterTurn switch to on positionReplaceResetCleanReplaceReplacePrime with clean waterCheck pipe and pipe connectionsCleanCleanCheck foot valve levelWater level lower than lift capacityCheck voltageCheck foot valve levelCleanToo small or dirty pipeCheck voltageCheck pipe and pipe connectionsCheck and consult factoryTROUBLE PROBABLE CAUSE ACTIONMotor does notrun.Motor runs butno water isdelivered.Pump does notdeliver to fullcapacity.Air spurts fromfawcets.TO THE END CONSUMERIf you have any problems with the product, before advising the store, where you’ve purchased the pump, please contact us at 514 337-4415 , and ask for our salesdepartment, and they will be pleased to help you with any questions you might have,concerning your installation.
Most popular related searches