Burke Water Systems Manufacturing Inc.
- Home
- Companies & Suppliers
- Burke Water Systems Manufacturing Inc.
- Downloads
- Submersible Sump Emergency Back-up Pump ...
Submersible Sump Emergency Back-up Pump - Brochure
2190 Boul. Dagenais West TEL: 514.337.4415LAVAL (QUEBEC) FAX: 514.337.4029CANADAH7L 5X9 info@burcam.comINSTALLATIONINSTRUCTIONSMODEL300402SUMPBUDDYPlease read theseinstructionscarefully. Failureto comply toinstructions anddesignedoperation of this system,may void thewarranty.Your pump has been carefully packaged at thefactory to prevent damage during shipping. However,occasional damage mayoccur due to rough handling.Carefully inspect yourpump for damages thatcould cause failures.Report any damage to yourcarrier or your point of purchase.© 2008 BUR-CAM Printed in Canada 300493ELECTRICAL PUMPAND PIPING NOTINCLUDEDW W W. B U R C A M . C O MFOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029SAFETY INSTRUCTIONS:(applicable to your electrical primary pump)This fine pump that you have just purchased is designed from the latest in material and workmanship.Before installation and operation, we recommend the following procedures:CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOUCOMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITHYOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM.WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRI-CAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUITBREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING.THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BEREMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PROTECTION.NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITHTHE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAK-ER, REMOVE THE POWER PLUG FROM THE RECEPTACLE.ASSUMING THAT YOU HAVE A SUMP PIT LOCATED IN YOUR BASEMENT FLOOR...YOUR SUMP PIT SHOULD BE CONSTRUCTED FROM CONCRETE, BRICK, TILE ORMORE RECENTLY A SUMP BASIN MADE FROM PLASTIC AND/OR FIBERGLASS. THEMINIMUM SIZE OF YOUR SUMP PIT MUST BE 18” IN DIAMETER AND NO LESS THAN 25”DEEP. WHEN PIT IS READY, PROCEED TO NEXT STEP.Material required for emergency sump pump applicationPump installationR Municipal water source with a minimum of 40 PSI and a maximum of 60 PSI.R Desired length of copper pipe and required fittings to link up municipal water source to sump buddy automatic valve.R Teflon tape.R Desired length of polyethylene pipe and T or Y fitting, to link up sump buddy discharge to existing discharge of electrical sump pump.ToolsR Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipeends, pipe wrench, adjustable wrench to tighten fittings, propane torch and welding material.2ABCDEFOR INFORMATION TEL: 514.337.4415 FAX: 514.337.40293APPLICATIONR This pump is designed to be connected toany existing conventional type sump pumpsystem, as an extra sump pump protection. R CAPACITY AT 60 PSI(municipal water pressure):5’ 581 US GPH Friction loss10’ 317 US GPH in pipe15’ 158 US GPH not includedFEATURESR Extra protection during power outage or in theevent of failure of conventional sump pump.R Easy to connect to existing conventional sumppump discharge line.R Automatic control valve activate the SUMPBUDDY.R No electricity required.R No battery required. INSTALLATION STEPS(see diagram on page 5)We recommend that you install your SUMP BUDDY in a location where there is adequateroom for servicing at a later date. Discharge line should be made from ABS or PVC 1 1/4” ,1 1/2” or 2” pipe.We do not recommend to install flexible drain kit due to friction loss. Head capacity and/ordischarge flow will be reduce in a large proportion.Use teflon tape on all connections.Keep suction screen and ejector clean.Check regularly your SUMP BUDDY to ensure its proper operation. Remember that solids ordebris in water should be removed from the sump pit.Remove electrical power of your existing conventional sump pump and verify that this sumppump is equipped with a check valve at pump discharge. If not, add a check valve beforecontinuing your installation. The sump pump check valve should be located at the primarypump discharge and installed below the “Y” fitting.Locate your SUMP BUDDY in an ideal position and cut the existing discharge line to installthe T or Y fitting. Cut the desired length of pipe to connect the discharge line from the checkvalve of the SUMP BUDDY to the T or Y fitting.Run this discharge line with fittings to adjust your SUMP BUDDY in vertical position.We recommend that the distance between the bottom of the SUMP BUDDY and the bottomof the sump pit be approximately 2”.STEP 1STEP 2STEP 3STEP 4Check valve requiredas per step 2.350353 1 ½”4Close municipal water supply. Run a supply line (not less than 1/2”, 3/4” recommended) to theideal position for an easy operation of the automatic control valve of the SUMP BUDDY. Install a ball valve near the pump area, to close water supply for servicing at a later date.Flush this new line, before next step, to remove any debris which may obstruct the water flow inyour SUMP BUDDY.Screw the automatic control valve to the supply line.Install the 900 galvanized bracket to the automatic control valve by using the two screws supplied.Install the stainless steel rod by simply screwing the two parts together. Using thelarge coupling, secure the rod connection.The top screw is to secure the top part andthe bottom screw is to secure the bottom partof the rod. The next step is to install the float by simplypassing the rod throught the float opening. Thenuse the small couplings to secure the float to therod by simply screwing the unit to the rod.The float should be set at least 2” higher thanthe conventional electrical pump setting, so thatthe back-up pump will not start prior to the mainelectrical pump. To complete the float installa-tion, simply insert the stainless steel rodthrought the 900 bracket, then install a rubbergrommet below the control valve level, theninsert the shaft throught the control valve andinsert the second grommet on the top, then setthe grommet adjustement to the proper locationto properly adjust the setting.Fix the vacuum breaker to the automatic control valve and screw the connecting hose. Adjust the length of the connecting hose and fix it to the sump buddy with a clamp.You are now ready to test your SUMP BUDDY. Restart municipal water supply, and confirm thatthere are no leaks in supply line. Try the automatic control valve by drawing up the lever. Waterwill go through the SUMP BUDDY. Push down the lever to shut off water flow.Fill the sump pit with water. Verify the action of the automatic control valve and the level of waterto start your SUMP BUDDY, then repeat the operation many times.Turn on electrical power of the conventionnal sump pump and verify the entire system.STEP 8STEP 9STEP 10STEP 11STEP 12STEP 6STEP 7STEP 13STEP 14STEP 15STEP 16STEP 5FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029STEP 11STEP 8 STEP 9STEP 10FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.40295STEP 2Remove electricalpower and verify forcheck valve.STEP 3Install T or Y fittingand link dischargelines together.STEP 4Adjust in verticalposition and leave2” under SUMPBUDDY.2”STEP 5Run a supply linewith a ball valvenear pump area.STEP 6Flush line toremove debris.STEP 7Screw automaticcontrol valve.STEP 11Install float and rodto automatic valve.STEP 12Fix vacuumbreaker.STEP 8Install the floatbracket.STEP 9Assemble float rod.STEP 10Install float. STEP 13Adjust length ofconnecting hose.STEP 14Test manuallyautomatic controlvalve operation.STEP 15Fill pit with water. Verify automatic actionand starting level.STEP 16Turn on electricalpower of conventionalsump pump.This ejector ispress fit fixed.Do not try tounscrew, you willdamage and voidwarranty.Please call us tomake maintenaceat 1-800 361-1820.TYPICAL INSTALLATION DIAGRAMFOR SUMP PUMPSTEP 1Install with soliddischarge line from1 1/4” to 2” pipesize.FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.40296TYPICAL INSTALLATION DIAGRAMFOR COLUMN PUMP2”STEP 2Remove electricalpower and verify forcheck valve.STEP 3Install T or Y fittingand link dischargelines together.STEP 4Adjust in verticalposition and leave2” under SUMPBUDDY.STEP 5Run a supply linewith a ball valvenear pump area.STEP 6Flush line toremove debris.STEP 7Screw automaticcontrol valve.STEP 11Install float and rodto automatic valve.STEP 12Fix vacuumbreaker.STEP 8Install the floatbracket.STEP 9Assemble float rod.STEP 10Install float. STEP 1Install with soliddischarge line from1 1/4” to 2” pipesize.STEP 13Adjust length ofconnecting hose.STEP 14Test manuallyautomatic controlvalve operation.STEP 15Fill pit with water. Verify automatic actionand starting level.STEP 16Turn on electricalpower of conventionalsump pump.This ejector ispress fit fixed.Do not try tounscrew, you willdamage and voidwarranty.Please call us tomake maintenaceat 1-800 361-1820.REPAIR PARTS MAY BE ORDERED FROM YOUR AUTHORIZEDPOINT OF SALE OR FROM BUR-CAM PUMPS7REPAIR PARTS LISTREF. PART DESCRIPTION1 350250 Pump body 2 350254K Ejector kit (incl.#3, 4,5,6)3 350255 Ejector seal 4 350254 Ejector 5 350256 Ejector “O” ring 6 350257 Ejector “O” ring7 350353A ABS check valve 1 1/4”8 350253 Coupling 9 350252 Hose clamp 10 350251 Connecting hose11 350260 Back flow preventorREF. PART DESCRIPTION12 350267 Automatic valve & bracket13 350248 Screws 14 350247 900 float guide 15 350246 Rubber stop16 350245 Stainl. steel float rod17 350244 Connection screws (2) 18 350243 Adjustment couplings (2)19 350266 Float20 350241 Rod coupling21 350242 Screws (4) for rod22 350265 Float/valve assembly(incl. # 11 to 21)724356811110912 15131416172120191822FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.40298TROUBLE SHOOTING GUIDE CHECKLISTNEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWERCONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWERFROM THE RECEPTACLE.Municipal water supply closed.Automatic valve closed.Float do not rise with water level.Suction or ejector clogged.Water level below suction in sump.Improper function or missing check valvein primary pump discharge.Discharge line clogged.Pumping height more than 15 ft.Municipal water pressure under 40 PSI.Municipal water supply partially opened.Automatic valve partially opened.Suction or ejector partially clogged.Leaky primary pump check valve.Discharge line partially clogged.Automatic valve does not shut off.Float is obstructedTurn on ball valve.Check manually the valve operation.Check for obstruction of float action.Clean.Adjust the float rod to shut off pump priorto low water level.Install a check valve below the “Y” fittingon your primary pump discharge base.Check all pipes.Reduce top lift to less than 15 ft.head.Run a 3/4” direct line from municipal watersupply to reduce friction loss in pipe.Turn on ball valve.Check manually the valve operation.Clean.Replace.Check all pipes.Check manually the valve operation.Check for obstruction or adjust rubber grommet to proper off andon position.TROUBLE PROBABLE CAUSE ACTIONNo water isdrawn out.Pump does notpump water tofull capacity.Pump does notshut off.TO THE END CONSUMERIf you have any problems with the product, before advising the store, where you’ve purchased the pump, please contact us at 514 337-4415 , and ask for our salesdepartment, and they will be pleased to help you with any questions you might have,concerning your installation.
Most popular related searches
