Coulton Instrumentation Ltd
- Home
- Companies & Suppliers
- Coulton Instrumentation Ltd
- Downloads
- Temperature Transmitter FRC Series
Temperature Transmitter FRC Series
Field-mounted Two-wire Signal Conditioners2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER(HART® communication, intrinsically safe/explosion-proof)MODEL FRCFunctions & Features• Universal input: mV, V, T/C and RTD• High accuracy• HART communication• Intrinsically safe and explosion-proof approval• CE marking (conforms to ATEX and EMC)• Optional stainless steel enclosure• Programming via hand-held communicator or via PC• A wide variety of T/C and RTD types• Self diagnostics• Input-output isolatedMODEL & SUFFIX CODE SELECTIONRELATED PRODUCTS• PC Con?gurator Software• HART modem* MACTek VIATOR RS232 HART® IF recommended• Hand-held communicator** Consult HART® Communication Foundation (HCF) web site : www.hartcomm.orgGENERAL SPECIFICATIONSDegree of protection : NEMA 4X, IP66/IP67Wiring conduit : See “Model & Suf?x Code”.Electrical connection : M3.5 screw terminals (torque 0.8 N·m)Materials Transmitter housing : Flame-resistant resin (black) Screw terminals : Nickel-plated brass Enclosure : Diecast aluminium standard (polyurethane coated) or stainless steel casting (equivalent to type 316, epoxy resin coated).Enclosure color : Body : Silver Cover : Blue (equivalent to Munsell GPB3.5/10.5)Silver for stainless steelMounting bracket assembly : Stainless steel 304Applicable pipe : 1” 1/2 min.; 2” max.Isolation : Input to output to outdoor enclosureUser-con?gurable parameters : · Input sensor type· Number of wires (RTD)· Input range· Output range (via HART® only)· Output calibration· HART communication mode· HART network modeBurnout (T/C & RTD) : Upscale, downscale or no burnout selectable (standard: upscale); Also detects wire breakdown and overrange input exceeding the electrical design limit for DC input.Cold junction compensation (T/C) : CJC sensor incorporatedDamping time : 0 to 30 sec. (standard : 0)FRCQQQQAMODELENCLOSURE0 : None *11 : Diecast aluminium2 : Stainless steel castingSAFETY APPROVALA : NoneC : CENELEC ?ameproof (ATEX)E : CENELEC intrinsically safe (ATEX)LCD DISPLAY0 : Without1 : WithWIRING CONDUIT *20 : None1 : 1/2 NPT2 : M20 s 1.53 : PG 13.5*1. Choose the suf?x code 0 for “Wiring Conduit”*2. Con?rm selectable combinations of approval and wiring con-duit types in the table below.N SELECTABLE WIRING CONDUITS SPECIFIC TO EACH APPROVAL‘N’ marked combinations are not selectable. APPROVALCONDUITA C E0 Y N Y1 Y Y Y2 Y Y Y3 Y N YEDS8-10fFuji Electric France S.A.S. DATE January 2010LCD DISPLAY (option)Features: · Indicates and setts input signal, engineer- ing unit and transmitter status.· Removable while the module is powered.Display size : 36 s 20 mm (1.41” s 0.79”)Characters : Color : Black Format : 2 rows of 5 alphanumeric characters; Top: 7.4 mm highBottom: 6.5 mm high6 status characters, 1.9 mm highDisplay range : -99999 to 99999Decimal point : Top row only; positioned between two charactersRead rate : 150 msec.Back light : NoneHART® COMMUNICATIONProtocol : HART® communication protocolHART® address range : 0 – 15 (standard: 0)Transmission speed : 1200 bpsDigital current : Approx. 1mA p-p when communicatingCharacter format : 1 Start Bit, 8 Data Bits, 1 Odd Parity Bit, 1 Stop BitDistance : 1.5 kilometers (0.9 mile)HART® communication mode : Master-Slave Mode and Burst Mode (standard: Master-Slave)HART® network mode : Point-to-Point Mode and Multi-drop Mode; auto-matically set to Multi-drop Mode when the address is set to other than 0.INPUTThe input is factory set for use with 3-wire Pt 100, 0 to 150°C.See Table 1 for the available input type, the minimum span and the maximum range.N DC mV & V Input resistance : 1MO minimumN THERMOCOUPLE Input resistance : 1MO minimum Burnout sensing : 130nA ±10%N RTD (2-wire, 3-wire or 4-wire) Input resistance : 1MO minimum Excitation : 0.2mA ±10% Allowable leadwire resistance : Max. 20O per wireOUTPUTOutput range : 4 – 20mA DCZero adjustment : 3.8 – 7.2mA (standard: 4mA)Span adjustment : 12.8 – 17.6mA (standard: 16mA)Operational range : 3.8 – 21.6mALoad resistance vs. supply voltage: Supply Voltage (V) – 12 (V)Load Resistance (O) = ––––––––––––––––––––––– 0.024 (A) (including leadwire resistance)INSTALLATIONSupply voltage : 12 – 42V DC (non-approved)12 – 28V DC (approved)Operating temperature: -40 to +85°C Electronics (See Safety Parameters for use in a hazardous location.)-30 to +80°C Display (full visibility)Operating humidity: 0 to 95% RH (non-condensing)Dimensions : See External Dimensions.Weight : FRC0 : Approx. 150 g including the LCD FRC1 : Approx. 1.3 kg FRC2 : Approx. 4.0 kgPERFORMANCEAccuracy : See Table 1 and “Explanation of Terms”Cold junction compensation error : = ±0.5°CTemperature coef?cient : ±0.015%/°C of max. range at -5 to +55°C T/C and DC mV : ±0.015%/°C at -40 to +85°C Pt 100, span = 100°C : ±0.015%/°C at -40 to +55°C ±0.03%/°C at 55 to 85°C Start-up time : Approx. 8 secondsResponse time : 1 second (0 – 63%) with damping time set to 0 and when not communicating via HART®.Supply voltage effect : ±0.003% x [Output Span] / 1VInsulation resistance : =100MO with 500V DC (input to output)Dielectric strength : 1500V AC /1 minute (input to output to outdoor enclosure)STANDARDS & APPROVALSCE conformity: ATEX Directive (94/9/EC) Ex ia EN 50020 Ex d EN 60079-1EMC Directive (2004/108/EC) EMI EN 61000-6-4 EMS EN 61000-6-2Safety approvalCENELEC: Intrinsically safe (ATEX) II 1G, Ex ia IIC; T4, T5 and T6 (EN 50020 : 2002)CENELEC: Flameproof (ATEX) ** II 2G, Ex d IIC; T4, T5 and T6 (EN 60079-1 : 2007)**FRC1 or FRC2SAFETY PARAMETERSOperating temperature for CENELEC (ATEX):T4 -40 to +80°CT5 -40 to +65°CT6 -40 to +50°CEx-data: Ui 30V DC Uo 6.4V DCIi 96mA DC Io 30mA DCPi 0.72W Po 48mWCi 0 µF Co 20 µFLi 0 mH Lo 10 mH• Thermocouple1) K thermocouple, 0 – 1000°C Absolute value accuracy (Table 1): 0.25°C 0.1% s 1000°C = 1°C > 0.25°C CJC error (0.5°C) added: 1 + 0.5 = 1.5°C 1.5°C / 1000°C s 100 = 0.15 % ? Overall accuracy including CJC error = ±0.15% of span2) K thermocouple, 50 – 150°C Absolute value accuracy (Table 1): 0.25°C 0.1% s (150 – 50)°C = 0.1°C < 0.25°C CJC error (0.5°C) added: 0.25 + 0.5 = 0.75°C 0.75°C / (150 – 50)°C s 100 = 0.75 % ? Overall accuracy including CJC error = ±0.75% of span• RTD1) Pt 100, -200 – 800°C Absolute value accuracy (Table 1): 0.15°C 0.15°C / (800 – -200)°C s 100 = 0.015 % < 0.1% ? Overall accuracy = ±0.1% of span2) Pt 100, 0 – 100°C Absolute value accuracy (Table 1): 0.15°C 0.15°C / 100°C s 100 = 0.15 % > 0.1% ? Overall accuracy = ±0.15% of spanINPUT TYPE, RANGE & ACCURACYN INPUT TYPE, RANGE & ACCURACY TABLE 1INPUT TYPE MIN. MAXIMUM ACCURACY SPAN RANGEDC mV & V 4mV -50 to +1000mV ±0.1% or ±10µV, whichever is greater (F.S. input =50mV) ±0.1% or ±40µV, whichever is greater (F.S. input =200mV) ±0.1% or ±60µV, whichever is greater (F.S. input =500mV) ±0.1% or ±80µV, whichever is greater (F.S. input >500mV)Thermocouple °C °F MIN. MAXIMUM CONFORMANCE ACCURACY MIN. MAXIMUM CONFORMANCE ACCURACY SPAN RANGE RANGE *1 SPAN RANGE RANGE *1 (PR) 20 0 to 1760 0 to 1760 ±1.00 36 32 to 3200 32 to 3200 ±1.80 K (CA) 20 -270 to +1370 -150 to +1370 ±0.25 36 -454 to +2498 -238 to +2498 ±0.45 E (CRC) 20 -270 to +1000 -170 to +1000 ±0.20 36 -454 to +1832 -274 to +1832 ±0.36J (IC) 20 -210 to +1200 -180 to +1200 ±0.25 36 -346 to +2192 -292 to +2192 ±0.45 T (CC) 20 -270 to +400 -170 to +400 ±0.25 36 -454 to +752 -274 to +752 ±0.45 B (RH) 20 100 to 1820 400 to 1760 ±0.75 36 212 to 3308 752 to 3200 ±1.35R 20 -50 to +1760 200 to 1760 ±0.50 36 -58 to 3200 392 to 3200 ±0.90 S 20 -50 to +1760 0 to 1760 ±0.50 36 -58 to +3200 32 to 3200 ±0.90 W 20 0 to 2315 0 to 2315 ±0.25 36 32 to 4199 32 to 4199 ±0.45N 20 -270 to +1300 -130 to +1300 ±0.30 36 -454 to +2372 -202 to +2372 ±0.54 U 20 -200 to +600 -200 to +600 ±0.20 36 -328 to +1112 -328 to +1112 ±0.36 L 20 -200 to +900 -200 to +900 ±0.25 36 -328 to +1652 -328 to +1652 ±0.45 P (Platinel II) 20 0 to 1395 0 to 1395 ±0.25 36 32 to 2543 32 to 2543 ±0.45RTD °C °F MIN. MAXIMUM RANGE ACCURACY MIN. MAXIMUM RANGE ACCURACY SPAN *2 SPAN *2Pt 100 (JIS ’97, IEC) 20 -200 to +850 ±0.15 36 -328 to +1562 ±0.27*1. [Accuracy or ±0.1% of span, whichever is greater] + Cold Junction Compensation Error 0.5°C*2. Or ±0.1% of span, whichever is greater. (For 2- or 3-wire RTD, the value is valid by the sensor calibration after the wiring is done.)EXPLANATIONS OF TERMSN ACCURACYThis transmitter’s accuracy is theoretically de?ned as the addition of A/D and D/A conversion errors: Accuracy = A/D Conversion Error + D/A Conversion ErrorThe A/D conversion error means that measured as HART signal which is A/D converted from the analog input signal.The D/A conversion error of this transmitter is relatively very small so that it does not really affect the unit’s overall perform-ance.The “Accuracies” given in Table 1 therefore equals the A/D con-version error.The temperature drift (coef?cient) or the cold junction compensa-tion error is not included in the “Accuracy.”N CALCULATION EXAMPLES OF OVERALL ACCURACY IN %• DC Voltage1) 0 – 200mV Absolute value accuracy (Table 1): 40µV 40µV / 200000µV s 100 = 0.02 % < 0.1% ? Overall accuracy = ±0.1% of span2) 0 – 4mV Absolute value accuracy (Table 1): 10µV 10µV / 4000µV s 100 = 0.25 % > 0.1% ? Overall accuracy = ±0.25% of spanSCHEMATIC CIRCUITRY & CONNECTION DIAGRAMCJCSensorA safety barrier must be installed for the intrinsic safety.The safety barrier must meet the Ex-data of this unit and must be approved for the hazardous location.OptionalBe sure to earth the unit s enclosure to meet the intrinsic safe or explosion-proof (flameproof) requirements.Close across the terminals 1 & 2 for 2-wire/3-wire RTD input.Limited to 250 – 11007 for HART communication.*1.*2.*3.*4.*5.1324DC mVAABBLCD Module *2ConnectorRTD & Resistance4-wire T/C3-wire2-wireABBABOutputDriverOutputComputationControl & DisplayControlButtonsInputComputationHARTComm.Low DriftAmplifier+–*3*1*5LOADOUTPUT24VDCNon-Hazardous LocationHazardous Location4 – 20mADCSafety Barrier*4*4 +–+–+–IsolationEXTERNAL DIMENSIONS & MOUNTING REQUIREMENTS unit: mm (inch)N FRC0With LCD Module1 2 3321 44+–Without LCD Module(Terminal Assignments)33 (1.30)59 (2.32) dia.LCD MODULE CONNECTOR2–5 (.197) dia. MTG HOLE24.5 (.965) deepHHC TERMINAL63 (2.48) max.27.5 (1.08)24.5 (.96)34.5 (1.36)48 (1.89)N FRC1, FRC24–M8, 12 deep92 (3.62)110 (4.33)70 (2.76)118 (4.65)7 (.28)max.39 (1.54)19 (.75)110 (4.33) dia. 19 (.75)2–1/2NPT or M20x1.5 or PG13.591.5 (3.60)104 (4.09)14 (.55)26 (1.02)MOUNTING BRACKET(optional)SPACE REQUIRED TO REMOVE COVER174 (6.85)114 (4.49)110 (4.33)Fuji Electric France S.A.S.46, Rue Georges Besse - Z I du Brézet63 039 Clermont-Ferrand cedex 2 — FRANCEFrance : Tél. 04 73 98 26 98 - Fax 04 73 98 26 99 International : Tél. (33) 4 7398 2698 - Fax. (33) 4 7398 2699E-mail : sales.dpt@fujielectric.frFuji Electric can accept no responsibility for possible errors in catalogues, brochures and other printed material. Fuji Electric reserves the right to alter its pro-ducts without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in speci?cations already agreed. All trademarks in this material are property of the respective companies. All rights reseved.Fuji ElectricYour distributor:Coulton Instrumentation Ltd17 Somerford Business Park, Christchurch, BH23 3RU, UKTel: +44 1202 480 303E-mail: sales@coulton.com Web: www.coulton.com
Most popular related searches
