Chandler Systems, Inc.

Treatment Systems Hydrox Brochure

Standard FeaturesCombines Aggressive Pressurized Aeration with theOxidation Power of Hydrogen Peroxide (H2O2)Treats Extreme Levels of Iron, Manganese & SulfurDisinfection Properties to Treat Iron, Manganese &Sulfur BacteriaCatalog Systems to 105 gpmCatalog Models for Pressure Systems (traditional3450 rpm Submersible Pumps)-or- Clean Water Backwash Systems (InstalledAhead of Atmospheric Tank)-or- Pressure Variable Speed System (Constant Pressure,Jet Pumps or Other Low Inlet Pressure Applications)Maximum Operating Pressure – 125 psi/110º FClack™ Control ValvesAeration Manifold Assembly Machined from SolidPVC Barstock Automatic Self-Regulating Air Volume ControlFilter-Ag Plus® Filter MediaNo Raw Water BypassChemical Feed Pump & Solution TankElectronic Control ValvesOptions2750, 2850, or 3150 Top-mount Control Valves Multiple Aeration Tank Sizes Extra Chemical Injection Ports on Aeration ManifoldSide-mount Control ValvesFlow Management with Motorized Ball Valves orStaged Diaphragm ValvesWater Quality Monitor Initiated RegenerationCustom Designed Systems, for Higher Flow RatesVarious Filter Medias Steel and ASME Rated Pressure VesselsTypical Use:Large Scale IrrigationPublic Water SystemsDairy OperationsIndustrial Pre-treatmentHotels/MotelsApartments/CondosNursing Home/ Assisted LivingLaundry FacilitiesFood/Beverage Mfg.Livestock OperationsSchoolsHospitalsOur HydroxR™ Treatment System combines aggressive aerationtechnology with the oxidation power of hydrogen peroxide for treat-ment of virtually unlimited levels of iron, manganese and sulfur gas.At the same time, bacteriological forms of these constituents arecontrolled without the creation of chemical byproducts, contacttanks or the on going maintenence of rebedding carbon filters. The included chemical feed pump package is equipped with a Degashead for self-priming operation. Only the highest quality controlsand materials are used. Our motor-driven piston control valve is themost reliable under even severe water conditions and resists com-mon adversaries such as dirt, iron and turbidity. Designed for use incommercial, industrial or domestic water applications.As we remain Committed to Innovation, Chandler Systemsprovides the design and engineering support to ensure the most ef-fective treatment solution for each installation. For a stand-alone in-stallation or a new construction project, replace or integrate newequipment into an existing process, we have the proper system op-tions available to meet your needs. HydroxR™ Treatment Systems Chandler Systems710 Orange Street, Ashland, OH 44805Toll Free: 1-888-363-9434 Phone: 419-281-6829 Fax: 419-281-2375 www.csih2o.com 11/4/11With “WS” Series Control ValvesChandlerSystems_SellSheet_Hydroxr_Layout 1 11/4/11 8:32 PM Page 1Product SpecificationsCommitted to InnovationChandler Systems710 Orange Street, Ashland, OH 44805Toll Free: 1-888-363-9434 Phone: 419-281-6829 Fax: 419-281-2375 www.csih2o.com 11/4­/11For “Pressure System” models, at ratedGPM, the inlet PSI at the HydroxR™ Tankmust be at least 25 PSI higher than maxPSI at service. If supply pump cannotachieve this pressure, then use “VariableSpeed Systems”If needed, pH can be increased by injecting soda ash or caustic into the HydroxR™ Tank ManifoldOperating InformationFor use on Potable Water Only Water Temperature Range 35º – 110ºFDo not use on microbiologically unsafe or unknown quality water Ambient Air Temperature Range 35º – 110ºFInstallation must comply with state and local plumbing/electrical codes Operating Pressure Range 20 – 125 psiTank warranty void if subject to vacuum Electronic Requirements 110v/60HzCommercial HydroxR™ Treatment SystemBackwash Cu.Ft. MediaPRESSURE VARIABLE SPEED Continuous Peak Flow Ctrl Valve Drain Tank Tank PerSYSTEMS SYSTEMS Flow Rate Flow Rate GPM Conn Size Line Size Qty SystemCUTP25-102-WS CUTP25-102VS-WS 9 14 13.5-15 1" 3/4" 13"x 54" 2 5CUTP40-102-WS CUTP40-102VS-WS 14 20 20 1" 3/4" 16"x 65" 2 8CUTP50-102-WS CUTP50-102VS-WS 18 22 25 1" 3/4" 18"x 65" 2 10CUTP40-103-WS CUTP40-103VS-WS 21 24 20 1" 3/4" 16"x 65" 3 12CUTP50-103-WS CUTP50-103VS-WS 27 30 25 1" 3/4" 18"x 65" 3 15CUTP70-153-WS CUTP70-153VS-WS 36 35 1 1/2" 1 1/4" 21"x 62" 3 21CUTP100-153-WS CUTP100-153VS-WS 45 45 1 1/2" 1 1/4" 24"x 72" 3 30CUTP100-154-WS CUTP100-154VS-WS 60 45 1 1/2" 1 1/4" 24"x 72" 4 40CUTP140-203-WS CUTP140-203VS-WS 75 70 2" 2" 30"x 72" 3 42CUTP140-204-WS CUTP140-204VS-WS 100 70 2" 2" 30"x 72" 4 56CUTP180-203-WSH CUTP180-203VS-WSH 105 105 2" 2" 36"x 72" 3 54Filter TankPipe Size NPTMODEL NUMBERS Service GPMHydroxR™ capability to remove Manganese fromwater is critically dependent on the Iron and pH lev-els as shown below:If the Iron to Then the pH mustManganese ratio is: be at least: 5:1 7.0 1:1 7.8 0:1 8.3Manganese RemovalFor effective Iron and Sulfur removal, yourppm's must be on or below these curvesIron and Sulfur Removal0204060801006 6.5 7 7.5 8 8.3 8.5ppmphIRONSULFURChandlerSystems_SellSheet_Hydroxr_Layout 1 11/4/11 8:32 PM Page 2