ULTRIX 100 Ultrasonic Level Transmitter Brochure
F E AT U R E S• Loop powered,two-wire 4-20 mA output• Choice of ranges up to:10, 17, 26, 33 or 50 feet• Intrinsically safe versions• Chemically resistantTeflon® nose section• NEMA 6 submersible, IP68• CE certifiedA P P L I C AT I O N S• Liquid and solid level sensing• Open and closed tanks• Filter beds• Wet wells/lift stations• Bulk storage tanks• Waste sumps• Flumes and weirsThe ULTRIX 100 transmitters are unique;they can be directly suspended from theirsignal cable and are NEMA 6. Additionally,they come with a Teflon® nose section for highchemical resistance and NPT threading formounting on flanges or tanks.The ULTRIX 100 uses a simple two step“magnetic key” calibration. The calibration data is held in non-volatile memory.U L T R A S O N I C L E V E L T R A N S D U C E RULTRIX™ 100Contegra’s ULTRIX™ 100 is a two-wire ultrasoniclevel transmitter that provides non-contactmeasurement suitable for a wide range ofmedia such as liquids, pastes, slurries, and solids.The ULTRIX transmits short ultrasonic pulsestoward the sensed media. The time taken forthe echoes to return to the sensor is calculatedand converted into a 4-20 mADC output that isproportional to the measured distance. TheULTRIX 100 sensors are self-contained, easy toinstall, accurate, reliable, and maintenance free.Thousands of these sensors have been appliedin a broad range of applications.ULTRIX™ 100Sensor CalibrationTypical InstallationsTo calibrate the 4 mA output, hold the transmitter atthe proper distance for the 4 mA level and touch themagnetic key against the “Z” (zero) calibration icon.To set the 20 mA level, hold the transmitter at theproper distance and touch the magnetic key to the“S” (span) calibration icon.The LEDs indicate normal operation, invalid mediarange, loss of echo, low power, and signal verification.The Ultrix 100 can be flange mountedatop a closed tank (right) or secured toa bracket (below). Additionally, anduniquely, the Ultrix can be suspendedby its signal cable.These two-wire, 4-20mA transmittersoperate up to 50 feetNEMA 6 construction,cable suspensionmounting, and anarrow beam anglemake the Ultrix idealfor use in demandingapplications.SPECIFICATIONS 5 8 10 15 F (flow)Range: Liquid = 0.8-17' 1.0-26' 1.3-33' 1.6-50' .8-10'Solid = 0.8-8' 1.0-12' 1.3-16' 1.6-24' —Resolution: .12" .12" .12" .12" .08" Beam Angle (included): 7º 8º 10º 11º 7º Beam “Shadow” Ratio: 1: 0.12 1: 0.15 1: 0.20 1: 0.20 1: 0.12 Frequency (kHz): 56 52 44 35 56 Treading (NPT): 2" 2.5" 2"Weight (including cable): 2.2 lbs 3.3 lbs 2.2 lbs Teflon® is a registered trademark of DuPont. ULTRIX™ andCONTEGRA® are trademarks of Contegra Inc. Specificationsare subject to change without notice.ULTRIX™ 100Ultrasonic Level TransmitterNEMA 6: For indoor or outdoor use to protect against hose-direct water, temporary submersion and damage from external ice formation.IP68: Protection against indefinite immersionSee www.contegra.com for additional information* The transducers of the Ultrix 100-10 and -15 have PVCsidewalls to enable greater ultrasonic impulse strength.Power: 17 - 30 VDC, 0.48 watts maximum, reverse polarity and transient protection Output: 4-20 mA (standard) or 20-4 mA Load: Rmax = (V supply-17) x 50 Accuracy: 0.25% of maximum span(Integral temperature compensation)Default Output: 3.8/4/22 mA selectable (4 mA std.) Setup: Single magnetic key for independent span and offset adjustment (provided)Dual magnetic keys for response rate and default mA adjustmentMemory: non-volatile EEPROM Operating Temp: -3º F to 167º F (104º F for Intrinsically Safe versions) Mounting: By the sensor’s cable or NPT threading on nose section Response Rate: Immediate or 6, 17, 33 or 66 ft/min (adjustable).17 ft/min is standard. Model F is immediate only(for flow measurement).Tracking Speed: 12 ft/s approaching, 15 ft/s receeding Maximum Pressure: 14 PSI Material:Housing: UPVC Transducer: Teflon® * O-ring: Nitrile Cable: PVC (15 ft) Enclosure Rating: NEMA 6 submersible, IP68(epoxy potted interior) Display: 2 operating/diagnostic LEDs on-board and visible Ratings: UL 508 and CE certified (std.),Intrinsically safe models are EEx i,a IIc T6 Ordering Information (see example below**)Model RangeUltrix 100 XXX5 (0.8-17 ft)8 (1-26 ft)10 (1.3-33 ft)15 (1.6-50 ft)F (0.8-10 ft) flowAccessories U100-MagAdditional MagnetPlease consult thefactory for moreinformation aboutmeters, power supplies andintrinsically safebarriers.Options IS = Intrinsically Safe ratedCal (4 mA SP, 20 mA SP)Config (Default mA, Response Rate)An ultrasonic level transmitter shall be providedto sense the liquid level of the _________ at thelocation as shown on the plan drawings and inaccordance with the manufacturer’s recom-mendations. The transmitter shall be a 4-20mADC, 2-wire, 17-30 VDC loop powered typewith its output signal directly proportional to the measured level excursion. The transducershall be UL listed.The transmitter shall be self-contained with aNEMA 6/IP68 housing. The transmitter shall becapable of being suspended by its signal cable.Its nose section shall be made of Teflon® with 2” NPT threading. The upper body shall be ofUPVC. The transmitter shall be a CONTEGRAULTRIX™ 100.The transmitter shall be third party approvedintrinsically safe.Engineering SpecificationsContegra Inc.1286 Carriage Hills DriveEagan, MN 55123PHONE: 651-905-0900FAX: 651-454-4665INTERNET: www.contegra.com©2002 Contegra Inc. All rights reserved. 10135-0001-02Represented by:M O U N T I N G O P T I O N S• Suspended by its cable• 2" or 2.5" NPT thread on nose section• Flange (flange sold separately)ULTRIX™ 100**A typical model number is ULTRIX 100 - 5 - IS which is an Ultrix 100 with a 17 foot (5 meter)range that is rated intrinsically safe. Accessories are specified as separate line items.
Most popular related searches