UniPak - UP108S/UP108D/UP108T - DC Input Alarm Trip Module Brochrue

UniPak™ UP108S/UP108D/UP108T DC Input Alarm Trip Module 877 3 GET IOS (877.343.8467)• Single, Double or Triple Alarm Trip • Con?gurable Input Range • Potentiometer Adjustable: Setpoint, Hysteresis and Delay • Input Sensor Power Supply • 3-Way Isolation -1500 Vac Isolation Power to Output • AC or DC Power (19-40 Vdc or 19-28 Vac) • DIN Rail Mount (TS 35) • Removable Terminal Blocks Input Range Current 0-20 mA or 4-20 mA 100 ? Input Impedance 20 Vdc Input Excitation @ 20 mA Voltage 0-5 V, 1-5 V, 0-10 V or 2-10 V ~1 M? Input Impedance Output Relays: UP108S - 1 SPDT, UP108D - 2 SPST, UP108T - 3 SPST 1 A, 30 Vdc 5 A, 250 Vac (resistive load) Response Time Adjustable: 0.3 to 30 s LED Status Green LED=Presence of Power Red LED=Alarm Indication Red LED Flashes after time delay expires General Specifications Performance Specifications Isolation 1500 Vac 3-way: in-out-pwr Error 0.05% Thermal Coefficient 0.02%/°C Humidity 30-90% @ 40 °C Operating Temperature 0 to 50 °C (32 to 122 °F) Storage Temperature -40 to 80 °C (-40 to 176 °F) Power 19-40 Vdc or 19-28 Vac Power Consumption 2.5 W Dimensions: 17.5 x 100 x 112 mm (w x h x d) (0.69 x 3.84 x 4.14 in) Weight: 200 g ( 7.1 oz) Ordering Information: IOS-UP-108S Single Setpoint Alarm Trip IOS-UP-108D Double Setpoint Alarm Trip IOS-UP-108T Triple Setpoint Alarm Trip IOS-Z113(S, D, T) Setpoint Alarm TripThe UniPak™ UP108 module comes in 3 models to better fit the product to the application requirements. The UP108S is a single setpoint alarm trip, the UP108D is a two setpoint alarm trip and the UP108T is a triple setpoint alarm trip. Each setpoint is independently adjustable with multiple-turn potentiometers. Each setpoint features DIP switch configurable high or low trip. The high trip will change the state of the relay as the input signal increases, the low trip as the input signal decreases. The action of the relay is also configurable to be normally open or normally closed. The adjustable hysteresis (deadband) and adjustable time delay, to eliminate nuisance alarms, affects all setpoints. The time delay can be set from 0.3 to 30 seconds. The input is configurable for the most popular current and voltage ranges and is able to provide excitation for two-wire sensors.Alarm Trip flexibility and use made simple from ioSelect, powered by Seneca (Z113).www.ioselect.comRev: 2/23/2011UniPak™ UP108 / Z113 DC Input Alarm Trip Module877 3 GET IOS (877.343.8467)5. Input (+) 6. Input Current Source 7. UP108S - NC, UP108D/T Alarm 2 8. UP108S - NO, UP108D/T - Alarm 1 19 to 40 Vdc or 19 to 28 Vac Not Polarity Sensitive *Do not exceed upper limits of supply voltage Power Wiring Instructions Switch Settings Terminal Connections Input Voltage Input INPUT SETTINGS 0-20 mA 4-20 mA 1 2 3 4 0-5 V 1-5 V 0-10 V 2-10 V Output CAUTION: Set the switches prior to applying power or connecting the input of the UP108 www.ioselect.comRev: 2/23/2011 Passive Input (4-wire Device) Input Input with Sensor Excitation (2-wire Device) 6 5 Dimension Diagram 5 4 + - 5 4 + + V 9 7 8 UP108S UP108D UP108T 2 3 8 9 Alarm 1 8 9 Alarm 1 7 10 Alarm 2 7 10 Alarm 2 11 12 Alarm 3 Test Point 1 4 0-5 Vdc + - = ON KEY = NA Function RELAY SETTINGS Relay energized in alarm Relay de-energized in alarm 1 2 Low Alarm High Alarm UP108S Function RELAY SETTINGS Relay energized in alarm Relay de-energized in alarm 1 2 3 4 Low Alarm High Alarm UP108D Alarm 1 Alarm 2 Function UP108T RELAY SETTINGS Relay energized in alarm Relay de-energized in alarm 1 2 3 4 Low Alarm High Alarm Alarm 1 Alarm 2 Alarm 2 TEST POINT Normal Function Setting Alarm 1 1 2 3 Setting Alarm 2 Setting Alarm 3 Test Point The Test Point output is a 0-5V signal that follows the setpoint pot as determined by the Test Point DIP switch settings. The output is equivalent to the percentage, that is: 0-5 V = 0-100%. If the setpoint is at 25% then 25% of 5V = 1.25 V, which is read between terminal 1 (+) and 4 (-). The UniPak™ UP108 is designed to be mounted on 35 mm DIN rail. Adequate ventilation may be needed to ensure optimal operating conditions. Avoid mounting modules over devices that generate heat. If operating at the high end of the temperature specifications (near 50 °C/ 125 °F) it may be necessary to separate the modules by at least 5 mm (0.2 in).Other conditions that may contribute to high operational temperature:· High power voltage (> 30 Vdc / > 26 Vac)· Panel temperature above 45 °CPower supply upper limits must not be exceeded. Excessive power level will result in damage to the module.Installation 1 2 3 4 5 6 7 8 9 10 11 12 Test Point and Setpoint Adjustment EN50081-2 EN50082-2 EN61010-1 1. Test Point (+) 2. Power 3. Power 4. Input Common and Test Point (-) 9. UP108S - COMMON, UP108D/T - Alarm 1 10. UP108D/T Alarm 2 11. UP108T Alarm 3 12. UP108T Alarm 3
Most popular related searches