Whelen Engineering Company, Inc.

Universal and Intelligent Power Supply Series Brochure

SERIES FEATURES¦ Scan-Lock™ Flash Pattern Control provides remote control of multiple flash patterns by letting the driver select/change flash patterns according to traffic conditions by toggling through multiple flash patterns and locking in the desired pattern.¦ Fully encapsulated electronics on Competitor™ Series & conformal coated circuit boards to resist moisture/vibration on the Competitor Series Plus™, UPS Series and ISP Series.¦ Competitor Series Plus features models available in 60 and 90 watt output versions, all with Scan-Lock flash pattern control.¦ All models have non-volatile memory that stores the pattern you want until you want to make a change.¦ Traffic Advisor™ patterns: Left, right, split sequences and a flashing mode are available on the Universal® Series UPS690 & Intelligent™ Series ISP188.¦ Additional outlets to choose from with two, four, six or eight outlet models depending on series.¦ Expanded outlet control with new control formats providing greater flexibility.¦ All models have Hi/Low power feature standard and selective switching (On/ Off control of lighthead pairs).¦ Field proven microprocessor based design for power supplies that are stable on power-up and immune from false triggering.¦ Auto-ranging input current and output power regulation which eliminates strobe lighthead flash intensity variations, regardless of strobe tube design (linear/helix) and/or the number of lightheads in operation and also input reverse polarity protection.¦ Output short circuit protection monitors circuitry automatically and turns power supply off due to output loading conditions, preventing damage. ¦ Easy to install and use with no internal jumpers or settings to configure before using.¦ Reliability with engineering by Whelen, the first name in strobe light design and manufacturing.¦ Warranty protection with two year and five year (HDP®,) factory direct warranties that are the best in the business. Power supplies may be returned for service directly to the factory without prior approval saving down-time, extra cost and handling.¦ Service with twenty-four hour turn around on repairs. Form# UPS0511With built-in intelligence and product enhancements, Whelen's family of Remote Strobe Power Supply Seriesoffers the widest range of full function models, performance, and economy to choose from.® POWER SUPPLY FEATURESModel InputReversePolarityProtectionOutputShortCircuitProtectionLowPowerControlNumberofOutletsOutletSwitchingAlternate/Simultan.Outlets(max)NumberofFlashPatterns1FlashPatternControl(external)InputCurrentRegulationOutputPowerRegulationWarranty(Years)Physical Data(Dimensions in inches H x W x D)CS240 yes yes latch/level 2 - 1x1 10 yes - yes 2 1-13/16 x 2-13/16 x 6-1/2CSP660yes yes latch/level 6 2x4 3x3 10 yes yes-2 2-1/2 x 5-7/8 x 6-11/16CSP690 -UPS64LXA yes yes latch/level 4 2x2 2x2 10 yes yes yes 5 (HDP) 2-1/2 x 5-7/8 x 6-11/16ISP94yes yeslatch/levelortoggle4 2x2 2x2 8yes yes yes 5 (HDP)2-3/8 x 6-3/4 x 7ISP188 8 2x2x4 4x4 16 + T/A 2-3/8 x 8-5/8 x 9-1/8 POWER SUPPLY ELECTRICAL DATAModel InputVoltage(volts)Optional24(volts)InputCurrent(amps)InputPower(watts)OutputEnergytotal(joules)2OutputEnergyall lamp on(joules)2Outputpowertotal(watts)2Outputpowerper lamp(watts)2Outputpowerper lamp(watts)3Outputpowerper lamp(watts)4Flashrate peroutlet(FPM)FlashRate peralternatepair(FPM)ImpulseRate peroutlet(FPM)ImpulseRate peralternatepair(FPM)AMECACertifiedtoSAE,NFPA,CA XIIIPhysicalDataWeight(lbs)CS240 12/24 standard 4.2/2.1 54 16 16 (5.8/3.4) 40 20 20 - 75 150 300 600 yes5 1.5CSP660 12/24 standard 6/3 77 24.5 8 (2.9/1.7) 60 1015 15 75 150 300 600 yes5 2CSP690 12 optional 9.4 120 36 12 (4.4/2.6) 90 15UPS64LXA 12/24 standard 7/4 90 30 15 (6/3) 75 18.75 18.75 18.75 75 150 300 600 yes 4ISP94 12optional9 115 36 18 (8/3.3) 9022.5 22.5 22.5 75 150 300 600 yes2.5ISP188 12 18 225 76 18 (8/3.3) 180 51 Scan-Lock Flash Patterns & model availability, see page 4.2 All lamps connected.3 Two alternating lamps connected.4 Four alternating lamps connected.5 Not NFPA Certified. Universal® Model UPS64LXA? Certified as system component to SAE & California Title 13 specifications? 4 outlet, 75 watt output (90 watt input), with 10 Scan-Lock™ flash patterns and synchronize wire? Simultaneous or alternating flash of lighthead groups, (2x2, 3x3, 2x2 + 2x2)? RFI suppression, with less than 1db degradation. ? Manual Hi/Low intensity control? Cast aluminum housing? Five year (HDP®) Heavy Duty Professional direct warrantiesCompetitor™ Model CS240? 2 outlet, 40 watt output (54 watts input)? Output power regulation on CS240? Composite housing? 2 year warranty? Available with Deutsch® Waterproof ConnectorsCompetitor Series Plus™? CSP660 - 6 outlet, 60 watt output (80 watts input)? CSP690 - 6 outlet, 90 watt output (120 watts input)? Composite housing? 2 year warrantyIntelligent™ Series? Similar features as the Universal Series above. ? ISP94 - 4 outlet, 90 watt output (115 watt input), with 16 flash patterns, programmable configurations for DOT, Serial and UPS applications ? ISP188 - 8 outlet, 180 watt output (230 watt input), with 16 flash patterns, programmable configurations for DOT, Serial and UPS Applicationsp )ngISP188UPS64LXAISP94CS240CSP660CSP690Whelen Engineering Company, Inc. and may be used only as set forth in the Guidelines for Use of Whelen Trademarks available at www.whelen.com. Unauthorized use of Whelen Trademarks for commercial purposes may constitute trademark infringement and unfair competition in violation of federal and state laws.Dual HA239 headlight flashing strobes.CSP660 installation with CenCom™amplifier.ISP94 installation.GLOSSARYInput Voltage: 12/24V: The power supply is designed to operate on both 12 volt and 24 volt automotive electrical systems (10 to 16 volts and 22 to 30 volts), without deviating from rated flashrate and output power.12V: The power supply is designed to operate on a 12 volt automotive electrical system only, (between 10 volts and 16 volts).Input Current: xx/yy: The xx value represents a typical input current drawn by the power supply at 12.8 volts. The yy value represents a typical input current drawn by the power supply at 25.6 volts.Input Power: The power drawn from the battery, expressed in watts, which is the product of the battery voltage and power supply current draw.Output Power (Total): The amount of the power, expressed in watts, delivered to all the flash lamps generated by the power supply. This is calculated as the product of total output energy times flash rate per outlet pair, per second (Ptout = Jt x FPM/60).Output Energy (Total): The summation of energy, expressed in joules, for every impulse of light contained in the flash or flash pattern of a lamp. Example: If the pattern is CometFlash®, and the chart shows a value of 15 (6/3), the power sup-ply will deliver an impulse pattern of 6/3/3/3 joules, the total energy is 15 joules.Output Energy (Per Lamp): The energy delivered to each lamp, expressed in joules, when all lamps are active assuming the lamps are of the same imped-ance, i.e. the lamps are of same type and age.Low Power Control: +Latch: If +12 or 24 volts (momentary or hard switched) is applied to the Hi-Lo input when the power supply is operating, it will switch to a low power mode. The power supply will remain in low power (latched) until it is turned off and +12 or 24 volts is removed from the low power control input. A momentary switch is preferred here.Low Power Control: Level: Applying +voltage to the Violet wire for more than 1 sec. holds the power supply in low power mode until that voltage is removed. A toggle switch is preferred here.+Toggle: Switching between power modes, from high power to low power and back from low power to high power, may be accomplished by applying +12 or 24 volts (momentary) to the Hi-Lo input each time a change is desired.The power supply will always start in the high power mode when the low power control line is grounded or left not terminated.Outlet Switching: If the power supply features outlet switching, and its power leads are connected to the battery, +12 volts applied to any of the Outlet Switching inputs will activate the power supply with either 2, 4, 6, or 8 lamps flashing. These inputs work independently of the flash pattern control inputs. When all outlets are turned off, no current (0 amps) will be drawn from the bat-tery.Impulse: A single ignition (pulse) of the strobe lamp. Multiple impulses can be grouped together to form a flash pattern, i.e. DoubleFlash, TripleFlash™, CometFlash, etc.Flash: A group of impulses. A single flash pattern only has one (1) impulse. The CometFlash pattern contains four (4) impulses.Flash Pattern Control (external): If the power supply features flash pattern control, applying +12 volts to the appropriate control input(s) will activate one of the patterns, “see footnote 1”.Input Current Regulation: The power supply is designed with intelligence to sense how many lamps are active and automatically set the input current to provide the optimum amount of power to each lamp. This prevents input current surges and eases the load on the electrical system.Output Regulation: Eliminates flash lamp intensity variations due to flash lamp impedance mis-matching that occurs with mixed use of lamps, i.e. linear and helix type lamps.Scan-Lock™ Flash Pattern Control: A flash pattern control feature which lets you toggle through multiple flash patterns and lock in the one you want, see page 4.NOTICE: For optimum performance and reliability, Whelen strobe power supplies are designed for use with Whelen flash tubes, strobe lightheads and cables only. Substitution of any of these components with non-Whelen products voids all warranties. Whelen Engineering reserves the right to upgrade and improve products without notice.UPS64LXA installation.®ENGINEERING COMPANY, INC.51 Winthrop Road, Chester, Connecticut 06412-0684 • (860) 526-9504 • Fax: (860) 526-4078 • www.whelen.com © 2011 Whelen Engineering Company Printed in the U.S.A. Code# 10378I-050311Traffic Advisor™ (F)The Traffic Advisor pattern offers a subset of four lighting patterns: Left, Right and Split Sweep plus Flash.The graphic below depicts the flash patterns moving across six lightheads.FlashSplit SweepRight SweepLeft SweepNote: Oscilloscope displays and graphic illustrations indicate the operation of one alternating pair of outlets. Oscilloscope presentations, showing combined operation of both outlets as a single trace, vary in time base.Time base is not to scale for graphic illustrations.TripleFlash™* (A thru F)The TripleFlash pattern is a burst of three strobe impulses with the first impulse at higher power for added emphasis.2x TripleFlash™ (E,F)Same burst as TripleFlash only twice the frequency in the same time period.MicroBurst II™* (A thru F)Each MicroBurst II contains two sets of DoubleFlashes. The lead impulse in each DoubleFlash is produced at higher power for emphasis.2X MicroBurst II™ (E,F)Same burst as MicroBurst II only twice the frequency in the same time period.MicroBurst III™* (A thru F)Each MicroBurst III contains two sets of TripleFlashes. The lead impulse in each TripleFlash is produced at higher power for emphasis.2X MicroBurst III™ (E,F)Same burst as MicroBurst III only twice the frequencyin the same time period.DoubleFlash* (A thru F)Each DoubleFlash is a burst of two strobe impulses, the lead impulse in each burst is produced at a higher power for emphasis.2X DoubleFlash (E,F)Same burst as DoubleFlash only twice the frequency in the same time period.RapidRate™* (A thru F)A fast, aggressive pattern of equally powered and spaced impulses operating at 240 RRFPM (RapidRate Flashes Per Minute).2X RapidRate™ (E,F)Same burst as RapidRate only twice the frequency in the same time period.ActionFlash™* (A thru F)A hybrid pattern that repeats a mix of three CometFlashbursts, followed by six RapidRate flashes.2X ActionFlash™ (E,F)Same burst as ActionFlash only twice the frequency inthe same time period.ModuFlash™* (A thru F)With the ModuFlash pattern, impulse rate and intensity are modulated to produce a sweeping (rising and falling) effect. In one full cycle of this pattern, impulse rate and intensity change inversely.2X ModuFlash™ (E,F)Same burst as ModuFlash only twice the frequency in the same time period.Flash PatternsActionScan™* (A thru D)Scans through all 10 Flash Patterns which are separated by a group of single flashes. (illustrations not shown)CometFlash®* (A thru F)Each CometFlash is a burst of four strobe impulses; the lead impulse in each burst is produced at a higher energy for emphasis.2X CometFlash® (E,F)Same burst as CometFlash only twice the frequency in the same time period.Scan-Lock™ pattern control which lets you toggle through ten flash patterns (marked with asterisk*) and lock in the one you want. Power supply using flash pattern is indicated in red letters.LongBurst™* (A thru D)Each LongBurst is a burst of five strobe impulses. This provides a constant “ON” Flash Pattern when lights are alternating.A - CS240B - CSP660C - CSP690D - UPS64LXAE - ISP94F - ISP188Whelen Engineeringreserves the right to upgrade andimprove productswithout notice.* American Employees, American Manufacturing, American PrideCometFlash® flash pattern displayed on a high-speed digital oscilloscope.
Most popular related searches