Eco Fluid Center Ltd. (formerly Utility Service Associates)

VSG Comparison With Ontario Hydro Standard Specification M-652-84

FLUIDCENTER 58 Garnock Avenue, Suite 300, Toronto, ON, Canada M4K 1M2 Phone: 416 466-3144 or 888 442-5008 Fax: 416 466-3807 VSG COMPARISON WITH ONTARIO HYDRO STANDARD SPECIFICATION M-652-84 (VSG meets or exceeds all requirements) TEST REQUIREMENT VSG min max Penetration, worked @25ºC, ASTM D-217 310 355 343 Dropping Point, (ºC), ASTM D-566 135 - 250 Oil Viscosity, ASTM D-445 @40ºC @100ºC 150 14 210 - 176 15.3 Water Washout Loss, @79ºC (%) - 20 6 Timken OK Load (kg), ASTM D-2509 18 - 25 Copper Strip Corrosion, 24h @100ºC, ASTM D-4048 - 1b 1b Apparent Viscosity, 0 to 50ºC (poise), ASTM D-1092 15 reciprocal seconds 100 reciprocal seconds 400 reciprocal seconds - - - 1500 800 400 500 120 70 Roll Stability, 4 hr @ 25ºC, % penetration change, ASTM D-1831 - 20 8 Compatibility with other qualified products, mixed 1:1, ASTM D-1831 Roll stability not to be inferior to the poorer of the mixture components Only qualified product is calcium based which is fully compatible Lead Content (%) - 0.1 <0.001 9/01