Dynotek Fluid Data Management
- Home
- Companies & Suppliers
- Dynotek Fluid Data Management
- Downloads
- Wellhead Pressure Transmitter
Wellhead Pressure Transmitter
D Y N O T E K 1 0 0 0wellhead pressure transmitterwww.dynotekflm.comP R O D U C T F E A T U R E S? ± 0.25% FS accuracy? NACE compatible wetted parts? Low-cost, rugged construction? Class 1, Div 1, instrinsically safe certified? Ranges from 60 to 5000 psiThe Dynotek 1000 is a rugged, low cost industrial transducer that is ideal for oil and gas fieldapplications. With an accuracy of ± .25% and exceptional stability, the 1000 is a highly reli-able sensor for measuring gas casing pressure or line pressure at the wellhead, pipeline pres-sure, compressor output or any other measurement requiring high accuracy and reliability at areasonable cost. The 1000 is available with intrinsically safe or explosion proof rating for haz-ardous environments.The 1000 is available in 4-20 mA current output and 1-5 volt output versions. Pressure rangesavailable are from 0-60 psi or 5000 psi. Delivery from stock or 1-2 weeks for larger orders.P R O D U C T S P E C I F I C A T I O N S? Operating pressure ranges 60, 100, 300, 500, 1000, 5000 psi? Overpressure The rated pressure can be exceeded by the following without degrading performance: 4 x for rangesup to 900 psi g: 2 x for range 1000 psi sg? Pressure containment 6 x full scall for vented gauge2500 psi for all absolute and sealed gauge ranges 2000 psi and below 20,000 psi for all absoluteand sealed gauge ranges above 2000 psi? Pressure media Fluids compatible with 316L Stainless Steel? Supply voltage 9 to 30 VdcThe minimum supply voltage (Vmin) that must appear across the transmitter terminals is 9 Vdc? Output 4-20 mA (2-wire configuration)? Zero and span offset ± 0.5% F.S.? Long term stability ± 0.2% F.S./annum? Combined non-linearity,Hysteresis and repeatability ±0.25% F.S. BSL maximum? Temperature limits Storage: -50º to +185º FCompensated: -4º to +180º F? Operating temperature range -40º to +185º F? Temperature effects ± 2% F.S. Thermal Error Band Maximum over compensated Temp Range? Weight 10 oz. nominal? Pressure connection 1/4” NPT female? Factory Mutual Approvals(CSA) Approvals (Pending) Intrinsically safe for Class 1, Div 1, Grps A, B, C, D for hazardous locations? Canadian Standards Association(CSA) Approvals (Pending) Intrinsically safe for hazardous locations Class 1, Div 1, Grps A, B, C, DJim Butler • 303-947-4202 (cell) • Dynotekjb@cs.comGeorge Downs • 303-748-6574 (cell) • Dynotekwy@cs.com13931 W. 54th Ave. • Arvada CO 80002 • 303-234-1409 (phone) • 720-479-8980 (fax)
Most popular related searches
