Zetron Inc.

Zetron - M1512 - Automatic Dialer - Brochure

APPLICATIONS• Economical alarm reporter for security• Machinery monitoring• Add voice/page alarms to fire/security systems• Pump/tank/lift station monitoring• Agricultural monitoring• Remote alarming via cellphone• Engine and battery monitoring • Remote reset/reboot via phoneFEATURES• Up to 80 seconds of natural voice messages• Remotely configurable• Dial up to 120 phone numbers• Optional wide-area alpha paging• 4 remote control outputs via DTMF• Cellphone compatible• Built-in configuration menus• 8 digital and 4 analog alarm inputs• Voice and programming are battery backedModel 1512 SentriDialSpec SheetINTRODUCTIONSentriDial is a full-featured, economical industrial autodialer. Users can monitor 8 discrete inputs (normally open or normally ground) and 4 analog inputs (voltage or current level) and control 1 relay output and 3 open collector outputs remotely via telephone. Upon sensing an alarm condition, SentriDial automatically alarms via a user programmable list of phone numbers with specific user recordable voice messages stored in solid state memory or optional alphanumeric text pages. Configuration is via a friendly menu driven interface that does not require special training for system operation. The standard SentriDial features a rugged, metal case. As an option, users can purchase the SentriDial integrated into a fiberglass or steel NEMA 4X case with integrated battery, charger, power supply, and space for a cellphone for rugged applications.TAP PAGINGTelocator Alphanumeric Protocol (TAP) is standard format for sending text paging information to a paging terminal from a computer or other intelligent machines. This option allows the SentriDial to send text messages associated with an alarm condition through an on-site paging terminal or wide-area paging service. Individual alarm messages can be up to 180 characters long allowing a detailed description of each alarm condition to be sent as a page.PROGRAMMABLE FEATURES PC DTMFVoice Messages All’s well X X Assign call list to inputs X X Select and set length of message X X Number of times to repeat message X X Set pause between calls X X Record/playback/clear the message X X Edit/remove call list phone numbers X XPage Alarms Enter alpha messages for wide-area paging X Set 1, 2, or 3 paging terminals to call X Set terminal phone #, password, parity X ZETRON AMERICAS PO Box 97004, Redmond, WA USA 98073-9704 (P) 1 425 820 6363 (F) 1 425 820 7031 (E) zetron@zetron.comZETRON EMEA 27-29 Campbell Court, Bramley, Hampshire RG26 5EG, United Kingdom (P) +44 1256 880663 (F) +44 1256 880491 (E) uk@zetron.comZETRON AUSTRALASIA PO Box 3045, Stafford Mail Centre, Stafford QLD 4053, Australia (P) +61 7 3856 4888 (F) +61 7 3356 6877 (E) au@zetron.com ©Zetron, Inc. All rights reserved. Zetron® and Zetron and Design® are registered trademarks of Zetron, Inc. All other trademarks are properties of their respective owners.See Zetron price list for option pricing. Specifications subject to change without notice. 005-0259J April 2011PROGRAMMABLE FEATURES PC DTMFAlarms Set thresholds for analog inputs X High and low reset, high and low threshold Set # of times to repeat alarm cycle X X Set time between retries X X Set acknowledge type: X X Call everyone as long as alarm present Call until everyone acknowledges Call until one person acknowledges Call until someone acknowledges, then call again if alarm is still present after wait period Enter 1-15 sec pauses between phone numbers X Enter phone numbers of up to 30 digits X Set input debounce time X Set inputs NO, NC, status, momentary, disabled X XControl/Status/Security Set security code X Set acknowledge code and wait period X Set # of rings before answering X Tone or pulse dialing X X Turn control outputs and relay on/off X X Set outputs to latched, momentary X Display status of each alarm X SPECIFICATIONSPower: 9VAC-RMS or 11-14VDC 80 mA idle, 90 mA typical, 250 mA maximum @ 12VDC 115 VAC with wall transformer Primary Fuse: 2 APhysicalDimensions: 10.25” x 8” x 1.9”Weight: 2 lb.Operating Temp.: 0-60 degrees C (32-140 degrees F)Inputs/OutputsAnalog Inputs: 4Range: 0-5VDC, 4-20 mAResolution: 8 bitProtection: + 48 VDC (maximum)Contact Closure Inputs (Digital)Number: 8Type: Contact closure to ground or 0-5 or 5-0 volt change Logic low: < 0.8VDC or < 5 ohm to groundLogic high: > 2.0VDC or > 2 Kohm to groundControl Relays (Outputs) Number: 4Type: Form CCapacity: 120 VAC, 0.5 A maximum 28VDC, 0.5 A maximum 60 VA maximumVoice: Natural recordable up to 80 secondsRS-232 Serial Interface: 4800 baud, 8 bits, 1 stop, No Parity Transmit, Receive, Ground No hardware handshakingProgramming Interfaces: RS-232 Port PSTN dial-up using DTMF Local direct DTMF telephone interfaceCommunication Interface: PSTN dial-up using DTMF telephone interfaceAudio Output: 20 mVP-P to 2 VP-PAudio Input: 1-2 VP-PApprovals: FCC Part 15 and 68, Industry CanadaTelephone InterfaceEnd-to-End Line: Standard connection 600 ohm balanced line, automatic line seizure for inbound calls using ring detect.Connector: RJ-11C modular 6-wire jack (only 2-wire, TIP/RING used)Ringer Equivalency: 0.45 dBMax power output to PSTN: -10 dBmDTMF power output to PSTN: -1.0 dBmDTMF Timing: 100 msec on, 100 msec off Tone or Pulse DialingORDERING/OPTIONS• Basic SentriDial without any voice• Voice Option – 10 sec each (limit 8)• TAP Paging Option (300 baud or 1200 baud), alphanumeric messages (180 characters maximum)• DeadBolt Lightning Surge Arrestor• 220VAC 50Hz Wall Transformer• 115VAC 60Hz Wall Transformer• NEMA Case, Battery, Charger, Power Supply
Most popular related searches