Zone Leak Monitor Panels U006-0001 Datasheet
LEAK DETECTIONVERIS INDUSTRIES800.354.8556 +1 503.598.4564 www.veris.comZone Leak Detection ControllerZone Leak Detection PanelsDESCRIPTIONLD300, LD1000, LDRA6 and LDRA6-MB control panels continuously monitor up to 1,000 ft. (300 ft. for the LD300) of SC, SC-Con, or SC-H detection cable per zone. If the cable detects fluid at any point along its length, the detection panel illuminates the corresponding zone LED, clearly indicating which zone is affected. An alarm (visual for LD300, audible for all others) signals the presence of a leak. Additionally, if the cable fails or loses continuity, the panel will activate a cable fault LED. The detection sensitivity can be set independently for each zone. A summary alarm relay output is standard.The LDRA6 can interface with a computer via an RS-232 port, through which 117 days of cable current level readings and the last 100 alarms can be accessed for analysis. The LDRA6-MB also offers an optional Modbus slave port allowing other devices to communicate with it.APPLICATIONS? Monitoring data centers, computer room under-floor areas, mechanical rooms, and electrical control centers? Protecting records storage rooms? Monitoring plumbing in facilities? Monitoring chilled beams? Monitoring chemical and fuel storage areasFEATURES? Monitor up to 1,000 ft. (300 m) of water leak detection cable per zone with the LD100, LDRA6, and LDRA6-MB or 300 ft. per zone with the LD300...application flexibility? Two LED indicators per zone...leak and cable fault (LD1000, LDRA6, and LDRA6-MB)? Sensitivity settings for each zone help eliminate false alarms...maximum detection accuracy? Summary alarm relay output...fast response? Alarm and trend logs of the last 100 alarms and 117 days of cable current levels, plus RS-232 and Modbus RS-485 ports (LDRA6-MB only)...output versatility SPECIFICATIONS Input Power LD300: 5VDC ±10%; LD1000: 24VAC/DC (±10%)@300mA max.; LDRA6, LDRA6-MB: 24VAC/DC (±10%)@600mA max.Inputs: Water Leak Detection Cable Requires 15 ft. (4.5 m) leader cable kit (LC-Kit) per zone Maximum Cable Length LD300: 300 ft. (91 m); LD1000, LDRA6, LDRA6-MB: 1000 ft. (305 m) Detection Response Time LD300: < 20 sec (10 sec typical); LD1000: Configurable for 10 sec or 2 min, ± 10% LDRA6, LDRA6-MB: 20-3600 sec, software adjustable in 10 sec increments, ± 2%Relay Output LD300: 2 Form C relays (leak and fault); 1A@24VDC, 0.5A resistive@120VAC; LD1000: 2 Form C relays (leak and fault); 1A@24VDC, 0.5A resistive@120VAC LDRA6, LDRA6-MB: 1 Form C summary alarm relay, 1 Form C relay for each zone/alarm; 1A@24VDC, 0.5A resistive@120VACCommunication Ports (LDRA6 and LDRA6-MB only): RS-232 & RS-485 1200, 2400, 9600, or 19200 selectable; no parity; 8 data bits, 1 stop bit Terminal Emulation (RS-232) VT100 Compatible (configuration) Modbus (RS-485) (LDRA6-MB only) Slave; RTU Mode; Supports function codes 03, 04, 06 and 16Alarm Notification Audible Alarm LD1000: 85 dBA@2 ft. (0.6 m); LDRA6, LDRA6-MB: 85dBA@2 ft. (0.6 m) re-sound disabled, 8, 16, or 24 hrs.Push Buttons LD1000, LDRA6, LDRA6-MB: 1 for reset, quiet, and testOperating Environment: Temperature 0° to 50°C (32° to 122°F) Humidity 5% to 95% RH non-condensing Altitude 15,000 ft. (4,572 m) maxStorage Environment -20° to 70°C (-4° to 158°F)Weight LD300: 3 oz. (85 g); LD1000: 27 oz. (766 g); LDRA6, LDRA6-MB: 4 lbs. (2 kg)LD300: CE; RoHS CompliantLD1000: CE, ETL listed; conforms to UL 61010-1, RoHS CompliantLDRA6, LDRA6-MB: CE; ETL Listed; Conforms to UL 61010-1, EN 61010-1, CAN/CSA C22.2 No. 1010.1, RoHS CompliantLD1000LDRA6/LDRA6-MBLD300LD300, LD1000, LDRA6, & LDRA6-MBHQ0001795.A 01121LEAK DETECTION800.354.8556 +1 503.598.4564 www.veris.comMODEL MANUF. PART # DESCRIPTIONU006-0002* LD300* Leak Panel, 1 zone, LED, 2 relay outputsU006-0001** LD1000** Leak Panel/Remote Annunciator, 1 zone, supervised, relay outputU006-0034** LDRA6** Leak Panel, up to 6 zones, supervised, relay outputU006-0036** LDRA6-MB** Leak Panel, up to 6 zones, supervised, relay output, Modbus RTUU006-0035 LC-KIT† Leader cable kit for SC cables (connects from leak panel to SC or NSC cable)U006-0061 LC-KIT-M†† Leader cable kit for SC-C and SC-H cables (connects from leak panel to SC-C or SC-H cable)U006-0004 FM1114 Reference map, framed (11” x 14”)U006-0037 WA-DC-05 Power Supply for LD300* Power supply not included; requires WA-DC-05 power supply.** Power supply not included; requires Veris PS24-7.5W power supply or equivalent.† Included with LD300 and LD1000.†† Not included with LD300 and LD1000. Required for installation of SC-C ad SC-H cables.DIMENSIONAL DRAWINGSAPPLICATION/WIRING DIAGRAMSLD300 or LD1000 basic installation with SC Sensing Cable and SD-Z Spot DetectorLD1000 LDRA6 and LDRA6-MBLD300LD300 WiringModel LED Indication Device StatusLD300 Solid green (on or off) Normal operationLD300 Flashing green (0.5 sec on/2.5 sec off) Cable faultLD300 Flashing green (0.5 sec on/0.5 sec off) Leak detectedLD1000 Solid green (on or off) Normal operationLD1000 1 amber Cable faultLD1000 1 red Leak detectedLDRA6/LDRA6-MB Solid green (on or off) Normal operationLDRA6/LDRA6-MB 1 green Power onLDRA6/LDRA6-MB 1 red Leak detectedLDRA6/LDRA6-MB 1 yellow Cable faultBLINK CODE KEYORDERING INFORMATION RoHSCompliantINTERTEKC USLISTEDCMLISTED3037024Power/AlarmLD300orSCNSCEnd Terminator (EOL)Leader cable kit (LC-Kit)Spot detector (SD-Z)LD1000 SC Cable Input White | Black | Green | Red 5VDC Input Fault Relay Output N/C | C | N/O Leak Relay Output N/C | C | N/O Leak Sensing Sensitivity (Top – High, Bottom – Low) Relay Output Con?guration(Top – Supervised, Bottom – Non-supervised) Power/Alarm2.7”(69 mm)4.4”(112 mm)PowerFaultLeakQuiet/Reset/Test5.5”(140 mm)4.2”(105 mm)Alarm/Zone 1Alarm/Zone 2Alarm/Zone 3PowerAlarm/Zone 4Alarm/Zone 5Alarm/Zone 6Test/Reset/Silence8.0”(203 mm)10.5”(267 mm)HQ0001795.A 01121
Most popular related searches