Environmental Regulations Equipment

760 Results found
Only show results in Virginia?
OK
  • Category: Environmental Management ×

  • Subcategory: Environmental Regulations ×

Model GD233 - Single Point Carbon Dioxide Detector And Alarm Unit

by TQ Environmental Plc     based in Wakefield, UNITED KINGDOM

The GD233 Single Point CO2 Detector is a stand alone Infra-red Carbon Dioxide detector, combined alarm and display unit. 24 V DC powered the basic model has a LED array to give an indication of concentration level and alarm active points. It also incorporates 4-20 mA analogue output for remote monitoring and can be fitted with 2 x internal alarm ...

Environment & Safety Resource Center

by Bloomberg BNA     based in Arlington, VIRGINIA (USA)

The Environment & Safety Resource Center is a comprehensive new source for environment, health & safety (EHS) news, analysis, legal and regulatory developments, and critical case law. This dynamic web platform is an all-in-one EHS research and compliance resource, and the latest addition to Bloomberg BNA’s popular suite of Resource ...

CCS - Internal `L` Berm

by Custom Chemical Solutions, LLC     based in Cody, WYOMING (USA)

The Internal “L” Berm is our standard berm for uprights composing your tank farm. This patent pending design is made to desired/required size to be EPA compliant with 3’ walls for 110% containment (other wall sizes available). Rust free, heavy duty aluminum framework supports the structure with our “L” braces ...

Model Type 10 - Air Pressure Regulator

by Marsh Bellofram Group of Companies     based in Newell, WEST VIRGINIA (USA)

The Marsh Bellofram Type 10 is a high-precision air regulator, designed to control output pressure with accuracy of 0.1% and high-repeatability, with very low sensitivity to changes in supply pressure, ambient temperature and flow.

Shipping by Ground – 49 CFR (US)

by The Compliance Center (ICC)     based in Niagara Falls, NEW YORK (USA)

The hazardous materials Road and Rail Placarding poster and chart are a comprehensive pictorial guide to the correct placarding requirements. Based on the latest DOT regulations.

Fossil Fuels

by Air Fuel Synthesis (AFS)     based in Darlington, UNITED KINGDOM

Fossil fuels - the need for change to a more renewable, eco-friendly and sustainable source of energy is needed. Everyone wants oil, but it is running out. This is why Air Fuel Synthesis is such a promising technology, why we have strong ethical principles, and why we aim to scale up rapidly as our expertise develops. Fossil oil supplies have ...

MONITOR TECH - Model MT100 - Data Acquisition System

by Monitor Tech Corporation LLC     based in Columbus, OHIO (USA)

MonitorTech delivers everything you need from our unique probe to our Data Acquisition System and reports.ALL EPA REQUIRED EMISSION GASES NOx (NO + NO2), CO, O2s wet/dry (moisture), SO2, Hcl, NH3, CO2,Opacity, Flow, CH4, H2S, H2, C6H14, C3H4, Cl, HCl, HCN etc.

CMC SmartCEMS - Model SCSL - Sample Line of PEMS

by CMC Solutions, LLC     based in Farmington Hills, MICHIGAN (USA)

The SmartCEMS Sample Line is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Sample Line will meet the requirements for sampling during model development and PEMS QA activity. The ...

CMC SmartCEMS - Model Probe - Predictive Emission Monitoring System (PEMS)

by CMC Solutions, LLC     based in Farmington Hills, MICHIGAN (USA)

The SmartCEMS Probe is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Probe will meet the requirements for sampling during model development and PEMS QA activity. The Probe is ...

CMC SmartCEMS - Model SCSIP - Sample Interface Panel

by CMC Solutions, LLC     based in Farmington Hills, MICHIGAN (USA)

The SmartCEMS Sample Interface Panel is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Sample Interface Panel will meet the requirements for sampling during model development and ...

Sustainable Fuel

by Air Fuel Synthesis (AFS)     based in Darlington, UNITED KINGDOM

Start reducing the transport carbon footprint with an eco-friendly alternative. Synthetic carbon-neutral fuels can be made “to spec” - no need to remove impurities by refining crude fossil oil into specific fuel types. Any fuel or crude-oil based material can ultimately also be made from synthetic hydrocarbons produced by the AFS ...

Regulatory Information

by Brady Corporation     based in Milwaukee, WISCONSIN (USA)

Safety Manuals help you stay up-to-date on the latest OSHA and other regulatory standards to keep your workplace as safe as possible.

Superall #38 - Degreaser, Cleaner

by SuperAll Products, LLP     based in Tomball, TEXAS (USA)

Safe, effective, and economical solution to your chemical problems. SuperAll #38 has been listed by EPA on Products Schedule for the National Contingency Plan. This listing allows the use of SuperAll #38 for fuel and oil spill wash downs (in accordance with state and federal regulations). SuperAll #38 is on the U.S. Environmental Protection ...

FALCO - Model 100 - Catalytic Oxidizer

by Falmouth Products Inc.     based in East Falmouth, MASSACHUSETTS (USA)

The FALCO 100 electric catalytic oxidizer treats air streams contaminated with volatile organic compounds. The catalyst provides VOC destruction efficiencies up to 99.5%. Operation, including startup, is fully automatic. Control system accurately regulates input loading and temperatures. The controls adjust a FALCO Vapor Control Valve (

MONSOL - Model D-R 290 - Compliant Continuous Opacity Monitoring System

by Monitoring Solutions     based in Indianapolis, INDIANA (USA)

Designed for cost effective stack opacity monitoring, the D-R 290 meets all the requirements of the U.S. EPA (40 CFR Part 60).

Model EMS421 - Complaint Opacity Monitors

by Environmental Monitor Service, Inc.     based in Yalesville, CONNECTICUT (USA)

The EMS421 Opacity & Dust Monitor meets or exceeds EPA regulation 40 CFR 60 appendix B, PS-1 and ASTM D 6216. It is the definition of reliability, featuring an intuitive 5.7″ color touch screen user interface and long life EPA compliant light source. The EMS421 utilizes dual beam measurement and the highest quality optics to assure ...

Municipal Waste Water Treatment Plants

by Global Resource Recovery Organization (GRRO)     based in Eldora, IOWA (USA)

Biosolids is the product created by treatment of sewage solids in Municipal Waste Water Treatment Plants. The thickened sludge is pumped to a belt press where it is dewatered to 13%-20% solids, which in most instances is Class B Biosolids in accordance with 40 CFR Part 503. The Tempest processes the Class B biosolid into a Class A material in one ...

Polyethylene Spill

by Hazmat Chemical Storage, Inc.     based in Tustin, CALIFORNIA (USA)

Polyethylene Spill Containment Pallets provide quick and easy compliance with EPA Spill Containment regulations for Hazardous Chemicals as set forth in 40CFR 264.175.

Ema - Stripping Machine

by Emak     based in Istanbul, TURKEY

It Peels off a very thin layer of jewelry with chemical method and reveals the true color of the metal brightly. Gold can be taken out directly from the machine, thus eliminating the need for recycling. With Capacities 175lt and 350lt. User-Friendly. Easy Installation. Recycles %100. Low Operation Cost. Ecological, Environment Friendly.

ETEC - NOx Control for Air Preheat Systems

by Entropy Technology & Environmental Consultants, Inc. (ETEC)     based in Houston, TEXAS (USA)

New advancements in combustion control technologies, such as flue gas recirculation (FGR) and low NOx burners (LNB), have made it possible to achieve ultra low NOx levels without using expensive post-combustion flue gas clean-up technology. For some natural draft units it may be possible to meet the most stringent of the NOx regulations with ...

Need help finding the right suppliers?

Let the XPRTs do the work for you