Filtration Performance: Turbidity & SDI Reduction, Particle Analysis nextSand vs. MultiMedia. - Case study
Test Conditions Water Source: Surface water (river water with silt and clay particles after a rain event in San Antonio). Equipment Description. Multimedia System. 36" bed depth comprised of #16 Garnet, #50 Garnet, 20x30 mesh sand and anthracite, operated at 12gpm/ft2. next-Sand System. 1/4x1/8 gravel to cover hub and laterals, 36" bed depth of 14x40 mesh next-Sand operated at 12 gpm/ft2. ...
-
What is Ultrafiltration’s Role in Water Treatment?
Ultrafiltration with semipermeable membranes can play an important role in water purification because of its compactness and efficiency Ultrafiltration (UF) is a water purification process in which ...
News
-
Reintroducing the OTT SVR 100
The Surface Velocity Radar OTT SVR 100 now comes with an integrated SDI-12 interface making it the ideal sensor to collect surface water velocity measurements. This simple and compact radar sensor provides data during floods or times of high ...
Equipment & Solutions
-
Showcase
Logging Transmitters
Sutron XLink product family offers a cost-effective Wi-Fi enabled datalogger with data transmission via Iridium or Cellular. Ideal for use with multiple digital and analog sensors supporting basic or advanced monitoring applications. The product comes in two models tailored to fit different application and budget requirements. The XLink 100 and XLink 500 carry over all the great capabilities from ...