Our trusted V Series valve, now with ease of maintenance. ValvTechnologies V Series valves are engineered to be leak-free and have a position-seated design, ensuring optimal flow while reducing overall cost of ownership. The new V1-R valve has a 4-piece assembly that allows for removal of the valve body and end cap, while the end connections remain in-line. Maintenance can now be made without the need for cutting or welding. The new V1-R: experience enhanced performance, reduced downtime, and seamless service, all in one innovative solution.
Most popular related searches
metal seated ball valve
high velocity oxygen fuel
drain vent
boiler feed pumping
fire protection system
water cooling
valve testing
cooling water
boiler feed water
soot blower
- Sizes: 5/8” – 4”
- Pressure Classes: ASME / ANSI Class 3100
- Materials of Construction: Carbon steel (A105) – Standard, Alloy steel (F22, F91) – Standard
- In Compliance: ASME B16.34
- PED: Nuclear ASME III Class 1, 2 and 3
- Nuclear Safety Related – 10CFR50 Appendix B: SIL
- End Connections: Socketweld, Buttweld – Standard
- Shutoff: Absolute Zero-Leakage Shutoff
- Simplicity of design: 4-piece valve assembly designed for ease of removal while connections remain inline. Field testable after repair, prior to insertion
- Through conduit design: No tortuous flow path. When open it has the highest possible Cv’s
- Fixed position: Quarter turn: no seating torques required.
- Hardened blowout proof stem: One piece, inserted through the body & shouldered
- Metallic body seal ring: Increases body integrity by eliminating external leakage.
- Live load packing gland: Minimum four bolt configuration with shallow stuffing box. Ensures consistent torque at variable pressures & temperatures
- Hard coated & mate lapped seats: High Velocity Hydrogen Fuel (HVHF) chrome carbide hard coating with Rockwell C of up to 72. Mate-lapped seats
- Seat designs: Hard coated, both ball and integral downstream seat to the end-cap to eliminate a potential leak path
- Stringent testing: Every valve is tested, documented, and serialized
- Four-year warranty: The very best in the industry. Covers internal seat leakage as well as external through the packing and/or body seal.
- 4-piece assembly that allows for removal, while end connections remain in-line. Maintenance can now be made without the need for cutting or welding. Benefit: Increased efficiencies, ease of use, reduced maintenance costs
- Through conduit design: No tortuous flow path. When open it has the highest possible Cv’s. Minimized wear & tear. Benefit: Minimized wear & tear, reduced vibration, reduced maintenance
- Fixed position – quarter turn: No seating torques required. Benefit: Improved safety
- Hardened blowout proof stem: One piece, inserted through the body & shouldered. Eliminates the weak link of collared & pinned designs. Benefit: Improved safety
- Metallic body seal ring: Increases body integrity by eliminating external leakage. Benefit: Improved reliability, zero-leakage shutoff
- Live-loaded packing gland: Minimum four bolt configuration with shallow stuffing box. Ensures consistent torque at variable pressures & temperatures. Benefit: Increased reliability
- Hardcoated & mate lapped seats: High Velocity Oxygen Fuel (HVOF) RiTech® chrome carbide hardcoating with a Rockwell C of up to 72. Mate-lapped seats.
Benefit: Wear & corrosion resistant, increased reliability, zero-leakage shutoff - Seat designs: Hardcoated, both ball & integral downstream seat to the end-cap to eliminate a potential leak path. Benefit: Increased reliability
- Stringent testing: Every valve is tested, documented & serialized. Benefit: Increased reliability, increased safety, total traceability
Fossil Power Applications
- Above and below seat drains
- Ash handling
- Attemporator spray control
- Boiler drains
- Boiler feed pump isolation
- Continuous boiler blowdown
- Electronic relief
- Feedwater heater drains
- Feedwater isolation
- Instrument isolation
- Main steam stop
- Recirculation
- Seal steam regulators
- Sight/gauge glass drains
- Soot blower regulators
- Startup vents
- Steam dump
- Turbine bypass systems
- Turbine drain
Nuclear Generation Applications
- Boiler feedwater
- Circulating water system
- Component cooling
- Condensate extraction
- Condensate cooling water
- Emergency feedwater
- Fire protection system
- HP safety injection
- HP & LP heater drains
- Heat exchanger vent & drains
- Main steam system isolation, drain & vent
- Power operated relief valve (PORV)
- Pressurizer drain & vent
- Rad waste system
- Reactor coolant pump drain & vent
- Reactor head vents
- Reactor water cooling vents & drains
- Safety injection system
- Secondary system isolation, drain & vent
- Service water system isolation
- Steam generator system
- Turbine by-pass
- Turbine drain & vent
- Fukushima tie ins