CerabarModel PMP75 -Absolute and Gauge Pressure

SHARE

Digital pressure transmitter with fully welded diaphragm seal for measurement in gases or liquids. The Cerabar PMP75 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. Designed according to IEC 61508 for use in SIL2/3 safety applications.

Most popular related searches
  • Large variety of different process connections and membrane materials

  • New TempC Membrane minimizes influences of ambient and process temperature fluctuations

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508

  • Cost savings with modular concept for easy replacement of sensor, display or electronics

  • Overload-resistant and function-monitored from the measuring cell to the electronics

Two chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections

  • Process temperature: -70 to +400°C (-94 to +752°F)

  • Pressure: -1/0 up to 400bar (-15/0 up to +6,000psi)

  • Accuracy: ±0.075%

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

  • Measuring principle

    Absolute and gauge pressure

  • Characteristic / Application

    Digital transmitter with piezoresistive sensor and diaphragm seal
    Modular transmitter
    Long term stability
    Minimum oil volume
    Enhanced safety via self diagnostic functions
    Secondary process barrier

  • Specialities

    Diagnostic functionalities

    Different languages in software

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC

  • Accuracy

    0,075% + influence of diaphragm seal

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -50°C...85°C
    (-58°F...185°F)

  • Process temperature

    -70°C...400°C
    (-94°F...752°F)

  • Process pressure absolute / max. overpressure limit

    1050bar (15,200psi)

  • Pressure measuring range

    400 mbar...400 bar
    (6 psi...6000 psi)

  • Main wetted parts

    Alloy C276
    316L
    Monel
    Tantalum
    PTFE-Foil

  • Process connection

    Threads
    Flanges (DIN, ASME, JIS) with flush membrane
    Tri-Clamp ISO02852
    Hygienic connections

  • Max. measurement distance

    7000m (22.966ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN 10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

  • Marine approval

    GL/ ABS

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing
    Separate housing

  • Application limits

    Measuring cell: Metal
    welded