Rhoss S.p.A

RHOSSModel TFAEY-TGAEY 4160÷4320 -Air Cooled Water Chillers

SHARE

Air cooled water chillers in Freecooling mode (TFAEY) and Freecooling NO-GLYCOL mode (TGAEY) with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.

Most popular related searches
  • Compressor: scroll type, rotary, hermetic complete with thermal protection and crankcase heater.
  • 4 capacity steps with high efficiency at partial loads.
  • Water side heat exchanger (evaporator): stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch (TFAEY) or flow switch (TGAEY).
  • Heat exchanger (water-water) in Free-cooling NO-GLYCOL mode: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch.
  • Air side heat exchanger (condenser): featuring finned coil with copper pipes and aluminium fins.
  • Fan: axial electric fans with external rotor, equipped with internal thermal protection and protection grilles and a proportional electronic device for continuous fan rotation speed regulation.
  • Control: microprocessor electronic control with Adaptive Function Plus logic.
  • Structure: load bearing structure made of galvanised sheet steel and painted with polyester powders.
  • The unit is also complete with:
    • compressors and fans MCBs;
    • clock board;
    • 3-way modulating water side valve.
  • T - High efficiency version (TFAETY-TGAETY).
  • S - Silenced version complete with compressor technical compartment soundproofing and reduced speed fans (TFAESY-TGAESY).
  • TFAETY: high efficiency unit in Freecooling mode.
  • TFAESY: silenced unit in Freecooling mode. 
  • TGAETY: high efficiency unit in Freecooling NO-GLYCOL mode.
  • TGAESY: silenced unit in Freecooling NO-GLYCOL mode.
  • PUMP with single or double electric pump, including an automatic pump in standby complete with safety valve. The pumps are available in the low or high pressure versions.
  • Electronic expansion valve.
  • Power factor correction capacitors (cosφ > 0.94).
  • Soft starter.
  • Cooling circuit high and low pressure gauges.
  • Metal filters or coil protection grilles.
  • Copper/copper or copper/pre-painted aluminium coils.
  • Digital input for double set-point.
  • 4-20 mA analogue input for shifting set-point.
  • Evaporator antifreeze heater, electric pumps if present.
  • Interfaces for serial communication with other devices.
  • Anti-vibration mountings.
  • Remote keypad with display.
  • Rhoss supervisors for unit monitoring and remote management.