- Home
- Companies
- AMS Analitica
- Products
- AirCube - Model PUF HVS Touch - ...
AirCube - Model PUF HVS Touch -Portable Dioxins and PAH Sampler
Entirely managed by a microprocessor, equipped with a new 4.3 "color touch screen display, with 220V mains power supply and direct current, through the use of an external battery pack, it is the most compact high-volume sampler model in absolute on the market. The use of the AirCube Puf sampler is allowed in emergency situations for sampling toxic substances in the air during environmental events with a high risk of pollution. The power supply option with an external battery pack allows it to be used even in situations where electricity is not available. Lightweight and compact, it does not have difficulties in transport, thanks to the double handle on the upper part of the instrument, and through a simple installation, use is available in a few minutes. Housed in an easy-to-carry and rain-resistant housing, it can be used even in the most critical weather conditions.
- Brushless moto blower
- Flow range up to 600 liters per minute * with automatic pressure drop compensation
- Electronic flow control with Venturi system device (ISO 5167)
- Compensation of flows and volumes at standard or environmental conditions (T and Pa)
- Programming of sampling cycles and times through electronic processor
- Data storage with the option of reviewing them on the display with minimum, average and maximum values
- 4.3 ”display - TFT 16 Mln colors - 480x272 pixel capacitive touch screen
- RS 232, USB port for data download. Network connection via LAN RJ45, Bluetooth and WiFi available as option
- Interchangeable sampling filter supports on 150, 102 and 55 mm
- Support filter cassette in acrylic POM material
During sampling protocols the following information are available on display:
- Instant and standardized sampling flow at standard and environmental conditions
- Average sampling flow rate
- Partial sampling volume standardized at standard and environmental conditions
- Ambient temperature and temperature at the flow measurement point
- Environmental Relative Humidity
- Atmospheric barometric pressure
- Wind speed and direction with sensors installed (option)
- Pressure drop on filter at display
- Data related to filter material and serial number of the filter used
- Graphical sampling trend with automatic calculation of the standard deviation
- Possibility of verification and calibration of the sensors by the user
Technical features:
- Flux among 5 to 55 liters per minute
- Usability pump range up to 5 m3 per hour
- Volumetric flow control with automatic load losses compensation
- Volumetric flow control through critical orifice
- Membrane pump kind double head
- Load losses compensation 600 mm/Hg with electronic control
- Direct flow display
- Weight 14 kg
- Total liters reading by way of dry gas volumetric counter and display
- Temperature control at Display with precision 0.1° C
- Setting normalization temperature chance
- Forced cooling system with exchange cycles every 5 seconds and dissipater in aluminum
Additional features:
- Dimensions 27x27x42 cm (LxDxH)
- External case in aluminum alloy painted with epossidic powders
- Compliant to the EN-12919:2001 norm
- EC Conformity on Electromagnetic Compatibility 89/336/EEC referred to the EN 50081-1, EN 6111-6-2, EN 55014-1, EN 61326-1 and EN 60204-1:1997-12 norms regarding instrumental tests of electrical safety
- Download sampling data software
- Motor pump assembly: Two stages brushless motor
- Absorption (Ampere): 15 at start / 4 during operating phases
- Maximum noise (250 l/min - 8 meters) 35 dBA - (30 dBA with noise reduction kit):
- Shelter type: Aluminum anticorodal non corrosive
- Shelter protection class: IP55
- Flow sensor: Venturi differential ISO 5167 compliance
- Flow sensor accuracy: Better than 1%on FS
- Sensor calibration: User selective calibration point
- Sampler flow range: 100-600 l/min
- Puf sampling: 102 mm inlet flow rate 100-300 l/min
- Filter type Rounded: 102mm filter holder with Puf tube support
- Operative temperature: -10/ +55°C (-30°C with heating control system)
- Data output: RS 232 - USB Port for data retrieving and firmware updates USB, LAN and BlueTooth connection available optionally GSM/GPRS modem available optionally
- Internal memory: 32Gb
- Display: 4.3" TFT 16 Mln colors - 480x272 pixel capacitive touch screen
- Temperature sensors: -10 / +80°C Res.0,1 °C Accuracy 1 °C
- Barometric pressure sensor: 300-1100 mbar Res.0,1 mbar accuracy 0.2%
- Optional sensors available: Wind velocity and direction (ultrasonic and mechanical)
- Relative Humidity: 0-100%/ 0,5%
- Dimensions (no inlet): 42x33x26 cm (hxlxp)
- Weight: 14Kgs
- Power: 220 Volt AC/50 Hz - 24Vcc
Sample holder support for PUF application is protected from atmospheric agents through an anti-rain cover, available on the upper part of the filter holder. All connectors for external users are watertight, guaranteeing a high standard of safety for operation.
AirCube Puf high volume samplers complying with reference methods: Dir.CEE 107-2004, ISO 12884 (Gas and Particles) ISO 16362 (Particles), US-EPA TO4A, TO9A e TO13A (Gas e Particles), ASTM D-6209.
Article : Code
- Air Cube PUF HVS-Touch portable high volume sampler: 600/A3T003PUF2K
- Sample inlet support 102 mm and cartridge : 600/AFPUF1002K
- Sample inlet support 150 mm and cartridge : 600/ADPT003TSPHVSK
- Sample inlet support 55 mm and cartridge : 600/A3000ALC-A1-FR
- PM10 selective inlet 200 l/min : 600/MVSPM1001K
- PM2,5 selective inlet 200 l/min : 600/MVSPM2501K
- 102 mm Quartz filters Box.25 pz : FAN/MFQ102
- 150 mm Quartz filters Box.25 pz : FAN/MFQ150
- 102 mm Glass Fiber filters Box.100 pz : NFS/GF1-102-100
- 150 mm Glass Fiber filters Box.100 pz : NFS/GF1-150-100
- AirCube Puf battery pack with battery charger : 600/PPA3P01K
- Complete PUF sorbent tube not conditioned (60 mm) : 600/AFPUF1110K
- Complete PUF sorbent tube not conditioned (90 mm) : 600/ADPT003TSPHVS011
- Replacement PUF 75x60 mm od box of 10, density 20 kg/m3 : 600/Z-4.412.756
- Replacement PUF 100x50 mm box of 10pz : 600/Z-4.410.510K