airmoVOC - Model C6C12 -Heavy Volatile Hydrocarbons Analyzer
Capable of anlaysing up to 32 compounds from C6-C12 (used in airmozone) or PAMS. The airmoVOC C6-C12 uses a valve with 1 sample trap. It also features a metalic capillary column. Miniaturization, sensitivity, mobility and flexibility are its main features.
MCERTS certified analyser for benzene measurement following EN 14662-3 norms
Everything from the sample port up to the data storage is integrated in a 19’’-rack 5U):
- Uninterrupted sampling with pre-concentration on 1 absorbent tube
- Gas chromatograph with 0.2 mm ID metallic column and programmable temperature gradient oven and pressure / flowcontrol of the carrier gas by piezo-valve
- Before delivery the analyser is tested for one week by our quality control department.The Vistachrom software enables the user to visualize and store data on a PC. Furthermore it enables the user to recalculate, calibrate the instrument export data and to set-up measurement.
The software allows the calculation of retention time, area, mass or concentration profiles.
C6 to C12 analysis:
- C6 (Hexane, Dimethylbutane) to C10 (Diethylbenzene, Naphtalene) and dodecane
Detection limit:
- Tri-methylbenzene: 10 ppt or 0.05 μg/m3
- Benzene: 10 ppt in standard 1 ppt with airmoVOC Expert
Detection range:
- 0.05 to 45 μg/m3 for Tri-methylbenzene and Benzene - (A3)
- 0,50 to 400 μg/m3 for Tri-methylbenzene and Benzene - (A2)
Note: Be careful with total mass and mass by compounds. Amplification 1: On demand to decrease the sampling volume.
Relative Standard Deviation:
- < 0.3 % over 48h (RT)
- < 3 % over 48 h (Conc.)
Results:
- Data storage
- MODBUS / JBUS communication protocol (option)
Cycle time:
- 15 min, 30 min, 40 min, 60 min
Gas supply:
- H2 (FID and carrier gas): 30 ml/min (inlet 2 bars; 1/16’’ swagelock)
- Air (FID): 180 ml/min (inlet 3 bars ; 1/8’’ swagelock)
- Sample inlet (vacuum pump) 1/4’’ swagelock
Sample volume:
- 30 to 700 ml (programmable)
Power supply:
- Main: 230 V / 115 V or 50 Hz / 60 Hz
- Battery: 24 V (option)
Electrical consumption:
- Mean: 150 VA, Peak 360 VA
Dimensions and weight:
- Rack: 19’’ - (5U)
- Height: 222 mm
- Width: 482 mm
- Depth: 600 mm
- Net Weight: 22 kg
- On-line results are transmitted via: MODBUS / JBUS or MGS1 communication protocol
- AirmoVOC Expert 1 ppt
- Automatic validation and calibration with internal CALIB
- 24 V power supply
- Hydrogen and zero air generator for transportable analysers
- Multiplexer: 2 to 32
- Purge module to extract VOC from water for online VOC in water analysis
- Internal or external multipoint calibration and zero with CALIB MFC, XXXCYL MFC, airmoCAL MFC or airmoCAL D
- Up to C16 with airmoVOC C6C16
- Clean air room monitoring The ambient air in clean air rooms needs to be constantly monitored for the safety of workers and of the production according to the environment. A clean air room is a room where the (...)
- BTEX and VOC This market is driven by law and legislations made in Europe and/or USA (US EPA). It deals with ambient air monitoring : analysis / calibration / automatic zero air in continuous 7 days a week. (...)
- The U.H.P. industry Air Liquide, Praxair, Air Products, BOC, Messer, Linde, Takachiho, Aga, etc. need to control the amount of impurities before delivery to customer in petrochemical or chemical industry. For pure (...)
- Chemical loss of volatile organic compounds and its impact on the source analysis through a two-year continuous measurement H.L. Wang, C.H. Chen, Q. Wang, C. Huang, L.Y. Su, H.Y. Huang, S.R. Lou, M. Zhou, L. Li, L.P. Qiao, Y.H. Wang
- Leaf level emissions of volatile organic compounds (VOC) from some Amazonian and Mediterranean plants A. Bracho-Nunez, N. M. Knothe, S.Welter, M. Staudt,W. R. Costa, M. A. R. Liberato, M. T. F. Piedade, and J. Kesselmeier
- Gas Chromatography: MCERTS Certification for Ambient Air Analysis on Benzene and VOCs Franck Amiet, Michel Robert, Dr Nicholas A Martin
- Ozone precursors (PAMS 56) and Toxics monitoring with airmOzone An all in one solution including dual combined autoGCs FID: airmoVOC C2C6 and airmoVOC C6C12.