Whether you require a turbidity meter or handheld device for the measurement of Blue Green Algae in reservoirs, the AP-LITE is the portable water quality meter for you. Sometimes multi-parameter measurement is not required, however the flexibility to change sensors is. Our AP-LITE solves this with its single parameter, removable sensor design. Simply remove your current sensor, install the new sensor and calibrate, you are then ready to take measurements.

Most popular related searches

This socket can house any of our 8 optical electrodes, which simply screw in and out.
Giving you a dedicated Turbidity sensor one day, and a standalone chlorophyll sensor the next!

Optical electrode options:

  • Turbidity
  • Chlorophyll a
  • Blue Green Algae (fresh or salt water options available)
  • Rhodamine
  • Fluoresceine
  • CDOM/FDOM
  • Refined Oil

Rugged Connection

All Aquaprobes feature the new AquaConn fully metal connectors. The AP-LITE features the all-metal AquaConn connectors. These high specification connectors feature large metallic key for a rigid fit, recessed pins for extra protection during pairing, guide markers on each part of the connector to allow you to instantly push the pair together in the correct alignment.

Continuous Turbidity Monitoring

The AP-LITE can be used with our sapphire turbidity sensor for continuous monitoring. Because you do not have to manually take samples, as with other portable turbidity readers, the AP-LITE can be deployed for continuous monitoring. Using our BlackBox you cn even hook this up to existing networks or to a telemetry device.

Standard Parameters

Dissolved Oxygen

  • Range: 0 – 500.0% / 0 – 50.00 mg/L
  • Resolution: 0.1% / 0.01mg/L
  • Accuracy: 0 – 200%: ± 1% of reading. 200% – 500%: ± 10%

Conductivity (EC)

  • Range: 0 – 200 mS/cm (0 – 200,000 µS/cm)
  • Resolution: 3 Auto-range scales: 0 – 9999 µS/cm, 10.00 – 99.99 mS/cm, 100.0 – 200.0mS/cm
  • Accuracy: ± 1% of reading

TDS*

  • Range: 0 – 100,000 mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0 – 9999mg/L, 10.00 – 100.00g/L
  • Accuracy: ± 1% of reading

Resistivity*

  • Range: 5 Ωcm – 1 MΩcm
  • Resolution: 2 Auto-range scales: 5 – 9999 Ωcm, 10.0 – 1000.0 KΩcm
  • Accuracy: ± 1% of reading

Salinity*

  • Range: 0 – 70 PSU / 0 – 70.00 ppt (g/Kg)
  • Resolution: 0.01 PSU / 0.01 ppt
  • Accuracy: ± 1% of reading

Seawater Specific Gravity*

  • Range: 0 – 50 st
  • Resolution: 0.1 st
  • Accuracy: ± 1.0 st

pH

  • Range: 0 – 14 pH / ± 625mV
  • Resolution: 0.01 pH / ± 0.1mV
  • Accuracy: ± 0.1 pH / ± 5mV

ORP

  • Range: ± 2000mV
  • Resolution: 0.1mV
  • Accuracy: ± 5mV

Temperature

  • Range: -5°C – +50°C (23°F – 122°F)
  • Resolution: 0.01° C/F
  • Accuracy: ± 0.5° C

Optional Parameters

Depth **

  • Range: 0-60m (AP-2000 & AP-5000), 0 – 100m (AP-7000)
  • Resolution: 0.01m
  • Accuracy: ±0.5% FS (AP-2000 & AP-5000), ±0.2%FS (AP-7000)

**Option on the AP-2000. Comes as standard on the AP-5000 & AP-7000

Ion Specific Electrodes***

Ammonium

  • Range: 0 – 9,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
  • Accuracy: ± 10% of reading

Ammonia†

  • Range: 0 – 9,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 9,000 mg/L
  • Accuracy: ± 10% of reading

Chloride

  • Range: 0 – 20,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 20,000 mg/L
  • Accuracy: ± 10% of reading

Flouride

  • Range: 0 – 1,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 999.9 mg/L
  • Accuracy: ± 10% of reading

Nitrate

  • Range: 0 – 30,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 30,000 mg/L
  • Accuracy: ± 10% of reading

Calcium

  • Range: 0 – 2,000mg/L (ppm)
  • Resolution: 2 Auto-range scales: 0.00 – 99.99 mg/L, 100.0 – 2,000 mg/L
  • Accuracy: ± 10% of reading

† Ammonium electrode required. Readings calculated from Ammonium, pH and temperature electrode values.

Optical Electrodes***

Turbidity

  • Range: 0 – 3000 NTU
  • Resolution: 2 Auto-range scales: 0.0 99.9 NTU, 100 – 3000 NTU
  • Repeatability: ± 2% of reading

Chlorophyll

  • Range: 0 – 500 µg/L (ppb)
  • Resolution: 0.01 µg/L
  • Repeatability: ± 2% of reading

Phycocyanin (Freshwater Blue-Green Algae)

  • Range: 0 – 300,000 cells/mL
  • Resolution: 1 cell/mL
  • Repeatability: ± 2% of reading

Phycoerythrin (Marine Blue-Green Algae)

  • Range: 0 – 200,000 cells/mL
  • Resolution: 1 cell/mL
  • Repeatability: ± 2% of reading

Rhodamine WT Dye

  • Range: 0 – 500 µg/L (ppb)
  • Resolution: 0.01 µg/L
  • Repeatability: ± 5% of reading

Fluorescein Dye

  • Range: 0 – 500 µg/L (ppb)
  • Resolution: 0.01 µg/L
  • Repeatability: ± 5% of reading

Refined Oil

  • Range: 0 – 10,000 µg/L (ppb)
  • Resolution: 0.1 µg/L
  • Repeatability: ± 2% of reading

CDOM/FDOM

  • Range: 0 – 2,000mg/L (ppm)
  • Resolution: 2 Auto-range scales:
  • 0.00 – 99.99 mg/L, 100.0 – 2,000mg/L
  • Repeatability: ± 10% of reading or 2ppm (whichever is greater)