DelphinModel Expert -Autonomous Data Logger for Different Measuring Tasks

SHARE

The FPGA-based Expert Logger device is particularly powerful and enables the processing of up to 46 analog input channels, both at low and high sampling rates. Measured values can be recorded precisely, stored autonomously and transferred automatically via USB or LAN to the Internet or PC for evaluation.

Most popular related searches
The multi-channel data logger for complex data acquisition

Do you need a highly flexible, compact and universal data logger for your most diverse measuring tasks? Then the Expert Logger is the optimal solution for your application.

With just one device, it is possible to independently process up to 46 analog input channels for your application, both at low and high sampling rates. All channels are galvanically isolated from each other. Your measured values are precisely recorded, monitored, pre-processed and can be stored internally in the device memory. LAN or USB are available for transferring the measured values to a PC or server. Thanks to the integrated interfaces such as PROFIBUS, Modbus and OPC UA, an optimum connection to your existing infrastructure is always possible.

With an OPC UA interface

OPC UA is becoming an increasingly established protocol and when used with the Expert Logger devices, measurement acquisition, monitoring and test stand automation applications can be made ready for open data exchange data in accordance with Industry 4.0/Internet of Things.

Both OPC UA servers and clients have been integrated into the Expert Logger devices to enable fast, easy and barrier-free data exchange with sensors and sub-systems also supporting OPC UA.

Many products such as frequency converters, controllers and regulators have already fully integrated OPC UA. The opportunities provided by OPC UA have been identified within the measurement and sensor technology sector with several sensors and actuators now available with OPC UA interfaces.

In addition to OPC UA, Expert Logger devices are also equipped with PROFIBUS, ModBus, CAN-Bus and serial interfaces for sensor and field level connections.

Solutions
  • Data logging
  • Environmental measurement technology
  • Product testing
  • Measurement data diagnosis
  • Laboratory data acquisition
  • Trials and tests
  • Energy optimization
Operation made easyDetachable screw terminals

The sensor connection is made by means of plug-in screw terminals. The large connection diagram clearly shows the channel arrangement. Despite the high channel density, the clarity is maintained. Four connection terminals each can be configured as two differential inputs for measuring voltage, current or thermocouples or for measuring a Pt100(0) in four-wire circuit.

Understandable configuration

Expert Logger can be configured conveniently from a PC using the configuration programme. The device configuration is retained in the Expert Logger even in a de-energised state. Configurations can be read out and saved on the PC. It is also possible to change the configuration offline without the Expert Logger device being connected. Offline configurations are then simply reloaded into the unit. With Expert Logger, configuration does not become the main task, but users can concentrate fully on the measuring task.

Intelligent signal processing

Signal processing by means of internal software channels simplifies the actual measuring task considerably. With the very flexible calculation channels, measured values can be further calculated and stored directly. Integrators calculate volumes or quantities directly from time-related measured values, such as mass or flow rates. Limit values can monitor measured values and be used to switch digital outputs or to automatically send e-mails. Complicated signal processing is also possible by means of impulse counters, time-step functions and operating hour counters. Mean values can be calculated and stored on a time-related or sliding basis. The software channels clearly distinguish Expert Logger from other data loggers and make them very popular with users.

  • Universal analog inputs (mV, mA, thermocouple, RTDs)
  • SDI12 interfaces for environmental sensors
  • 32 GB internal memory for up to 960 million measured values
  • PUSH function to send measurement data to the internet
  • LAN and USB interface to a PC or network
  • Monitoring and data logging in a single device

Universal, communicative, reliable

Below is a list of the main features of Expert Logger. If you have any questions please contact us.

OPC UA interface
  • Server/Client interface
  • Suitable for Industry 4.0
  • Open and barrier-free communication
Sensor connection
  • Universal analog inputs (mV, mA, thermocouple, RTDs)
  • Digital inputs and outputs
  • Plug-in screw terminals
Internal data storage
  • 32 GB internal memory for up to 960 million measured values
  • Time stamps at msec resolution
  • Readout via LAN or USB interface
External data storage
  • Data recorded to external storage media (USB, NAS)
  • PUSH function to send measurement data to the internet
  • Event-triggered recording with pre and post histories
PC and field bus interfaces
  • LAN and USB interface to a PC or network
  • CAN-Bus interface for reading / writing identifiers
  • Field bus interfaces PROFIBUS DP, Modbus
Signal processing
  • Averaging (middle, min, max, RMS values)
  • Integration of time signals into volumes, masses or working values
  • Computational functions (basic functions, polynomial, trigonometric ...)
Serial and SDI12 interfaces
  • SDI12 interfaces for environmental sensors
  • Serial ports RS232 and RS485
  • Configuration of individual ASCII protocols
Remote monitoring
  • Automatic notification via email or text messaging
Battery and rechargeable operation
  • Independent operation possible with batteries or rechargeables
  • User-defined wake and measuring intervals
Monitoring functions
  • Monitoring and data logging in a single device
  • Limit value setting for any sensor signal or calculation channel
  • Controlling digital outputs with user-defined triggering
Touch display

The touch display enables users to configure the Expert Logger‘s basic settings such as the IP address and network mask. The display also simultaneously shows selected measurement data. The display operates via either touch or an external USB mouse.

Here you will find an overview of the standard and optional hardware interfaces and protocols Learn more about the variety of interfaces of our measurement technology software.
Versions

Expert Logger

Technical information digital inputs

  • Input signal: low: 0 .. 1V / high: 5 .. 100 VDC@3,5 mA
  • Frequency range / width counter: 0,2 Hz .. 1 MHz, respectively 0,2 Hz .. 250 Hz / 64 bit
  • Galvanic isolation: ±400 VDC to PE / other channels

Technical information digital outputs

  • Max. switching voltage / current: 50V / 2,5A
  • PWM function / Pulse duty factor: Basic frequency 5 Hz .. 10 kHz / 1:1000
  • Galvanic isolation: ±400 VDC to PE, other channels

Data storage

  • Data storage internal: 2 .. 14 GB (approx. 30 million measurement values per GB)
  • Data storage external: USB, NFS, CIFS, (S)FTP

Interfaces / protocols

  • Sensor bus SDI12: 1: 1: 0: 0
  • COM1 und COM 2: RS485, 9-pole sub-D plug/ASCII, Modbus RTU, PROFIBUS DPV1 Slave
  • COM 3: RS485, 9-pole sub-D plug/ASCII, Modbus RTU
  • LAN: 1000 Base-TX
  • WLAN (optional, alternative to WWAN): 802.11 b/g/n
  • WWAN (optional, alternative to WLAN): UMTS, LTE max. 100 Mbit/s
  • USB: Device 2.0 Host 2.0 / low / full / high
  • TCP / IP protocols (LAN, WLAN, WWAN, USB): Modbus TCP, OPC UA
  • CAN / RS 232/485: 2x CAN 2.0/ Modbus RTU, SCPI, ASCII

General technical information

  • Dimensions / weight: H 210 x B 80 x T 125 mm / 750 g
  • Fixing: Rail mounting DIN EN 60715 or screw fixing
  • Signal connections: Plug-in screw terminals, 96 terminals in 2 rows, max. 1.5 mm²
  • Temperature range: -20 .. 50° C
  • Power supply: 12 .. 24 VDC / ± 10%
  • Power input normal mode: max. 10 W
  • Power input sleep mode: 5 mW@12 V, 10 mW@24 V