Benchtop Flow Cytometer

SHARE

Adding more colors and lasers to a newly designed cytometer is a logical but standard design improvement; Stratedigm is anything but standard. Not only did we increase the number of parameters from 22 to 30 and the lasers from 4 to 6, we’ve also doubled our throughput, increased our dynamic range to 5 decades, created more spatially separated interrogation points, and boosted our sensitivity up to 300%! All of these major improvements are in the same footprint and at the same price as our first S1000 launched in 2008. And with our Anti-Obsolescence Guarantee you’ll know your cytometer will be with you for many years to come. This is our commitment to Cytometry Without Compromise™.

Most popular related searches
  • Configurable and scalable up to 6 lasers and 30 parameters
  • Best-in-class two-year warranty
  • Future-proof system with easy field upgrades
  • Excellent resolution < 2.5% CV
  • Industry-leading sensitivity < 80 MESF
  • Extensive range of particle sizes from 0.2 µm to 40 µm
  • Patented 3rd Generation Smart Detect™ Technology
  • Patented Laser-Trimming technology for simultaneous detection of particles from 0.2 µm to 7 µm
  • Patented OptiSymmetric™ excitation architecture
  • Revolutionary Ghost Detect™ module for measurement of background fluorescence without a physical trigger
  • Seamless integration with automation options
Laser:
  • System is designed to support up to 6 lasers with spatial separation
  • Laser options:
    • Solid-state 372 nm – 100 mW
    • Solid-state 405 nm – 100 mW
    • Solid-state 488 nm – 150 mW
    • Solid-state 532 nm – 100 mW
    • Solid-state 552 nm – 100 mW
    • Solid-state 561 nm – 100 mW
    • Solid-state 640 nm – 100 mW
    • Solid-state 805 nm – 100 mW

**Other lasers available upon request

Detector Parameters and Data Acquisition:

  • Dynamic range:
    • Acquisition: 5 decades
    • Analysis: 7 decades
  • Linearity: R2 > 99%
  • Forward scatter (FSC) – enables separation of unfixed platelets from noise
    • FSC resolution: < 500 nm polystyrene beads
    • FSC scales: log and linear
    • FSC parameters: width, peak-height, area
    • Optional FSC photomultiplier (PMT) detector
    • Optional Quad-FSC: 375, 405, 488, and/or 640 nm
  • Side scatter (SSC) – resolves lympho-, mono-, and granulocytes
    • SSC resolution: < 200 nm polystyrene beads
    • SSC scales: log and linear
    • SSC parameters: width, peak-height, area
    • Optional Dual-SSC: 405 and/or 488 nm
  • Fluorescence channels:
    • Standard number of colors: 26
    • Sensitivity: < 80 MESF
    • PMT scales: log and linear
    • PMT parameters: width, peak-height, area
    • Time: 13 μsec resolution
 

Analysis Rate and Carryover:

  • Analysis rate: up to 20,000 events/sec
  • Carryover: < 0.1% with automatic backlash between samples

Sample Input:

  • Dead volume: < 8 μL
  • Minimum sample volume: < 20 μL
  • Maximum particle size: 40 μm
  • Patented low insertion force single tube loading

Fluidics Tray:

  • Integrated fluidics tray does not increase the footprint of the flow cytomer
  • Automated startup, shutdown, and cleaning cycles
  • Automated decontamination procedure using onboard cleaning solution for all components in contact with sample
  • Tank Capacity: 4 L sheath, 4 L waste, 4 L auxiliary solution
  • Optional automated sheath tank fill and waste drainage

Operating Conditions:

  • Operating Conditions: 60-86 °F (15-30 °C)
  • Size (including fluidics tray): 21.5″ W x 21″ D x 24″ H (54.6 cm W x 53.3 cm D x 61 cm H)
  • Weight (including fluidics tray): < 70 lbs (35 kg)
  • Power: 110/115/230 VAC, 50-60 Hz