Benchtop Flow Cytometer
FromStratedigm Inc.
Adding more colors and lasers to a newly designed cytometer is a logical but standard design improvement; Stratedigm is anything but standard. Not only did we increase the number of parameters from 22 to 30 and the lasers from 4 to 6, we’ve also doubled our throughput, increased our dynamic range to 5 decades, created more spatially separated interrogation points, and boosted our sensitivity up to 300%! All of these major improvements are in the same footprint and at the same price as our first S1000 launched in 2008. And with our Anti-Obsolescence Guarantee you’ll know your cytometer will be with you for many years to come. This is our commitment to Cytometry Without Compromise™.
Most popular related searches
benchtop flow cytometer
flow cytometer
particle sizing
cytometer
decontamination procedure
waste drainage
waste operator
fluorescence standard
cytometry
decontamination
- Configurable and scalable up to 6 lasers and 30 parameters
- Best-in-class two-year warranty
- Future-proof system with easy field upgrades
- Excellent resolution < 2.5% CV
- Industry-leading sensitivity < 80 MESF
- Extensive range of particle sizes from 0.2 µm to 40 µm
- Patented 3rd Generation Smart Detect™ Technology
- Patented Laser-Trimming technology for simultaneous detection of particles from 0.2 µm to 7 µm
- Patented OptiSymmetric™ excitation architecture
- Revolutionary Ghost Detect™ module for measurement of background fluorescence without a physical trigger
- Seamless integration with automation options
- System is designed to support up to 6 lasers with spatial separation
- Laser options:
- Solid-state 372 nm – 100 mW
- Solid-state 405 nm – 100 mW
- Solid-state 488 nm – 150 mW
- Solid-state 532 nm – 100 mW
- Solid-state 552 nm – 100 mW
- Solid-state 561 nm – 100 mW
- Solid-state 640 nm – 100 mW
- Solid-state 805 nm – 100 mW
**Other lasers available upon request
Detector Parameters and Data Acquisition:
- Dynamic range:
- Acquisition: 5 decades
- Analysis: 7 decades
- Linearity: R2 > 99%
- Forward scatter (FSC) – enables separation of unfixed platelets from noise
- FSC resolution: < 500 nm polystyrene beads
- FSC scales: log and linear
- FSC parameters: width, peak-height, area
- Optional FSC photomultiplier (PMT) detector
- Optional Quad-FSC: 375, 405, 488, and/or 640 nm
- Side scatter (SSC) – resolves lympho-, mono-, and granulocytes
- SSC resolution: < 200 nm polystyrene beads
- SSC scales: log and linear
- SSC parameters: width, peak-height, area
- Optional Dual-SSC: 405 and/or 488 nm
- Fluorescence channels:
- Standard number of colors: 26
- Sensitivity: < 80 MESF
- PMT scales: log and linear
- PMT parameters: width, peak-height, area
- Time: 13 μsec resolution
Analysis Rate and Carryover:
- Analysis rate: up to 20,000 events/sec
- Carryover: < 0.1% with automatic backlash between samples
Sample Input:
- Dead volume: < 8 μL
- Minimum sample volume: < 20 μL
- Maximum particle size: 40 μm
- Patented low insertion force single tube loading
Fluidics Tray:
- Integrated fluidics tray does not increase the footprint of the flow cytomer
- Automated startup, shutdown, and cleaning cycles
- Automated decontamination procedure using onboard cleaning solution for all components in contact with sample
- Tank Capacity: 4 L sheath, 4 L waste, 4 L auxiliary solution
- Optional automated sheath tank fill and waste drainage
Operating Conditions:
- Operating Conditions: 60-86 °F (15-30 °C)
- Size (including fluidics tray): 21.5″ W x 21″ D x 24″ H (54.6 cm W x 53.3 cm D x 61 cm H)
- Weight (including fluidics tray): < 70 lbs (35 kg)
- Power: 110/115/230 VAC, 50-60 Hz