Biomatik Corporation

BiomatikModel EKU02002 -Human 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) ELISA Kit

SHARE

Format: 96-Well Plate.  Species Reactivity: Homo sapiens (Human).  Sample Type: Tissue homogenates, cell lysates and other biological fluids.

Most popular related searches

Detection Range

1.56-100 ng/mL

Sensitivity

0.56 ng/mL

Estimated Turnaround Time

7-11 business days

Target Name

11-Beta-Hydroxysteroid Dehydrogenase Type 1

Target Synonyms

11DH; 11-beta-HSD1; HDL; HSD11; HSD11B; HSD11L; SDR26C1; Corticosteroid 11-beta-dehydrogenase isozyme 1; Short Chain Dehydrogenase/Reductase Family 26C,Member 1

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Intra-assay: CV

Detection Method

Colorimetric

Assay Time

3 hours

Application

ELISA

Assay Type

Double-antibody Sandwich

Shipping Condition

Ice packs

Storage

Short term: 4°C; Long term: see manual.

Precaution of Use

The Stop Solution is acidic. Do not allow to contact skin or eyes.

Expiry Date

8 months

UniProt ID

P28845

Specificity

This assay has high sensitivity and excellent specificity for detection of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1).

Cross Activity

This assay has high sensitivity and excellent specificity for detection of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1).

Test principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 11-Beta-Hydroxysteroid Dehydrogenase Type 1 (HSD11b1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Assay procedure summary

1. Prepare all reagents, samples and standards; 2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37°C; 3. Aspirate and add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 90 µL Substrate Solution. Incubate 10-20 minutes at 37°C; 8. Add 50 µL Stop Solution. Read at 450nm immediately.

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Restrictions

For Research Use Only. Not for use in diagnostic procedures. Not for human or animal drug or food use.

Quality Assurance

Biomatik ELISA Kits are not typically pre-assembled as finished products due to limited shelf life. Before shipping, each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Detection Range, Sensitivity, and Precision. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation. Please always refer to the hard copy manual included in the kit before experiment.

Research Area

Enzyme & Kinase;Metabolic pathway;Endocrinology;Cardiovascular biology;Neuro science;Hepatology;Hormone metabolism;