- Home
- Equipment
Refine by
Gecil Environmental Equipment & Supplies
8 equipment items found
Manufactured by:GECIL Process based in69450, FRANCE
Fully automatic distillation unit, in accordance with ASTM D1160 method, distills crude oil residue or lubricating cuts with automatic procedure from preheating to reduced pressure, up to the final boiling point (FBP) and return to atmospheric pressure, without any intervention of the ...
Manufactured by:GECIL Process based in69450, FRANCE
The DH87 & DH87 TWIN units are specially designed for crude evaluation laboratories to remove water from raw crude prior to performing D2892 distillation with quantification of water content and safe operation without any operator ...
Manufactured by:GECIL Process based in69450, FRANCE
Our fully automatic batch distillation unit distills any kind of samples with automatic procedure from atmo. to reduced pressure, with operation intervention (approx. 5min) only to remove prepared fractions at the end of each 3-4 hour sequence (if more than 12 fractions need to be prepared). Unit includes a column in accordance with customer application and a stainless steel boiling flask with ...
Manufactured by:GECIL Process based in69450, FRANCE
Fully automatic ASTM D1160 unit for distillation of crude oil residue or lubricating cuts, with automatic procedure from preheating to reduced pressure. No operator intervention up to the final boiling point (FBP) and automatic return to atmospheric ...
Manufactured by:GECIL Process based in69450, FRANCE
Our fully automatic distillation unit in accordance with ASTM D2892 method, distills crude oils or cuts with automatic procedure from debutanization to reduced pressure, with operation intervention (approx. 5min) only to remove prepared fractions at the end of each 3-4 hour sequence (if more than 12 fractions need to be prepared). Unit includes a D2892 column and a stainless steel boiling flask ...
Manufactured by:GECIL Process based in69450, FRANCE
Fully automatic ASTM D2892 unit for distillation of crude oils, bio-fuels or petroleum cuts, with automatic procedure from initial heating to reduced pressure. No operator intervention up to the final boiling point (FBP) and automatic return to atmospheric ...
Manufactured by:GECIL Process based in69450, FRANCE
The DH87 & DH87 TWIN units are specially designed for crude evaluation laboratories to remove water from raw crude prior to performing D2892 distillation with quantification of water content and safe operation without any operator ...
Manufactured by:GECIL Process based in69450, FRANCE
Our fully automatic batch distillation unit distills any kind of samples with automatic procedure from atmo to reduced pressure, with operation intervention (approx. 5min) only to remove prepared fractions at the end of each 3-4 hour sequence (if more than 12 fractions need to be prepared). Unit includes a column in accordance with customer application and a glass or stainless steel boiling ...