- Home
- Equipment
Refine by
Zebron Environmental Equipment & Supplies
25 equipment items found
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Low Polarity for a Wide Range of Applications; Rugged, high efficiency, and MS Certified low bleed. Well-suited for true boiling point separations. Excellent resolving power of critical pairs in complex petrochemical samples. Used for “fingerprinting” and routine quality control analyses (e.g., citrus ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
New Glass Infusion technology provides higher efficiency and greater column-to-column reproducibility. Increased accuracy for high temperature simulated distillation analysis. Up to 70 % more efficiency than other columns. Improved resolution of ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Unique low polarity si-arylene column for MS detectors. Provides alternative selectivity to standard 5-type phases. Often used for confirmation of pesticide, PCB, or other environmental sample. Good tool for sample screening to identify unknown ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Specially designed for the separation of all types of pesticides, herbicides, and insecticides. Well-suited for dual column analysis with Zebron ZB-MultiResidue™-2. Performance exceeds US EPA Method 8081A specifications for chlorinated pesticides. Low activity, decreased breakdown of sensitive pesticides such as DDT. MS Certified phases provide low bleed performance for pesticide ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Low Bleed, Intermediate Polarity Selectivity for GC/MS; Intermediate polarity column for high molecular weight analysis. Inert to minimize analyte adsorption, improve efficiency, and reproducibility. More rugged (longer column life) than other polar phases. Excellent for trace analysis with bleed-sensitive detectors (MS, FID, ECD, ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
High polarity column with excellent thermal and chemical stability. Provides better peak shape for underivatized acids. Especially suited for organic acids, free fatty acids, and alcohols. Bonded, solvent rinsable FFAP phase. Replaces ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Meet EPA Method 8270D Requirements Out-of-the-Box! This new technology delivers improved performance for challenging semi-volatile analyses such as PAHs, phenols, and amines. Improved peak shapes and responses are observed as a result of Enviro-Inert™ deactivation technology. While typical GC columns are QC tested for general requirements, the ZB-SemiVolatiles GC column is tested using a ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Guaranteed, direct replacement to Restek Rtx -CLPesticides columns, Resolve multiple chlorinated pesticide classes on one pair with enhanced, fine-tuned selectivity, Meet requirements for 7 EPA methods by GC/ECD (8081, 8082, 8151, 504, 505, 508, and 552), Instantly save on every ZB-CLPesticides column and kit with everyday low ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Alternate Selectivity for Mid-Polarity Analyses; Fast run and re-equilibration times for enhanced sample throughput and productivity. Provides alternate selectivity to phenyl phases with similar ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Optimized for trace and active compound analysis, Zebron PLUS GC liners undergo a unique chemical deactivation treatment resulting in a remarkably inert GC inlet ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Low Bleed Performance for GC/MS: Very low bleed (MS Certified) especially suited to high sensitivity GC/MS. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity. Extremely inert for active compounds such as drugs, pesticides, acids, and bases. ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Inferno: Rugged Performance Up to 430 °C: Rugged, high temperature stable (430 °C), polyimide-coated fused silica phase. Robust column performance for high temperature bake outs. True boiling point separation for hydrocarbon distillation methods. Recommended for chemists struggling with high boilers, contaminants, or carry-overs. ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Low Polarity for a Wide Range of Separations; Versatile column recommended for a wide range of applications. Great column for unknown samples. Resilient to dirty samples – long column ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Low Bleed Performance for GC/MS; Most popular starting column for method developers. Arylene Matrix Technology (AMT) provides a highly stable arylene phase for enhanced resolution of PAHs and multi-ring aromatic compounds. Low bleed (MS certified) especially suited to high sensitivity work using ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Highly inert for improved peak shape of acidic/basic compounds, drugs of abuse, and pesticides. MS certified low bleed levels provide maximum sensitivity. Industry leading QC specifications ensure column-to-column performance. Traditional bonding chemistry provides the same selectivity as the ZB-5 ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Non-metal, high temperature stable (430 °C), MS Certified phase for high boiling compounds. Rugged high temperature, polyimide coated, fused silica tubing. Robust column performance for high temperature bake ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Non-metal si-arylene GC column stable to 400 ˚C. Good tool for general screening to identify unknown samples. Rugged column performance for high temperature bakeouts. Individually tested for low bleed, MS ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Performance that exceeds US EPA Method 8081A specifications. Low activity, decreased breakdown of sensitive pesticides such as DDT. MS Certified phases provide low bleed performance for pesticide confirmation by ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Specially tested to ensure response of DDT, Endrin, Endrin Aldehyde, and Endrin Ketone. Guaranteed column for pesticide analysis. Equivalent to USP Phase G46, EPA Method 8081 ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
First non-metal, enhanced durability 35 %-phenyl phase witih 400 °C temperature stability. Great for high molecular weight compounds. Individually tested for low bleed, MS ...
