BWBModel BIO 943 -Flame Photometer for Biological Applications

SHARE

Purpose Built Flame Photometer with specialized software, firmware and hardware. The BWB BIO 943 is an offshoot of the popular BWB BIO. A simplified menu structure and enhanced Li detection make it a welcome addition to the BWB family. The ability to calibrate and measure Sodium, Potassium, and Lithium at the same time with the same dilution (from 1:6 to 1:100) streamlines throughput in many laboratories. We have retained the ability to enter and store two user-defined calibration curves should the user wish to readily measure differing sample types.

Most popular related searches

When connected to a PC with the BWB FP-PC app, the user can create .pdf files, .csv files, data presentations and reports that include all the key analysis data. The FP-PC Software also allows setup of the Automatic Fluid Handling System, AFHS, originally designed to work specifically with the BIO-943 unit.

The software enables you to view and edit the calibration curves. The intuitive user-friendly operation of the BWB BIO 943 spans all languages and appeals to all levels of users. The BWB BIO 943 is the must-have instrument in today’s research laboratory.

For sites that do not allow PCs or data acquisition in the test lab, the Printer provides the “hard copy” required for QA and QC purposes. The environmentally friendly print ink used by the printer has a minimum character capture life of 10 years. The printer is also compatible with other readily available paper stock.

To enhance accuracy and reproducibility there is an option to use either Caesium or Lithium as an Internal Reference System (IRS) that acts as an internal standard to adjust small changes during calibration and measuring.

  • Specially configured for a range of user interests
  • “IRS” (internal reference standard) caesium or lithium option
  • Single point calibration correction
  • Internal reference standards
  • 5 and 6 point multi-ion calibration standards for two separate calibration curves
  • Analysing Li, Na and K
  • Operator independent determination of results
  • Advanced automated determination of results
  • Integrated printer with environmentally friendly ink
  • IQ, OQ, PQ web-based certification standard on bio 943and available on all BWB FES units

Sample rate 

  • 2-3.5ml/min

Tubing materials 

  • Silicone and Tygon®  

Specificity

  • Na/K/Li = equal in concentration at

Required desk space for Instrument  

  • 50cm (H) x 45cm (W) x 45cm (D)
  • For Safety reasons the Flame photometer requires 1m of unobstructed space above to allow dissipation of heat from the chimney.

Instrument size 

  • BIO 943 Flame Photometer 51cm (H) x 38cm (W) x 41cm (D) (20in x 14in x 16in)

Shipping

  • 62cm (H) x 55cm (W) x 47cm (D) (24in x 22in x 19in)

Weight 

  • BIO 943 Flame Photometer 15.3kg
  • Shipping – BIO AV Flame Photometer 25kg

Optimal range

Multi-point calibration

  • Na – 0.0043 – 300mmol/l*
  • K – 0.0013 – 200mmol/* 
  • Li – 0.0072 – 20mmol/l*
  • *With required Dilution Ratios

Reproducibility 

  • <1% Coefficient of variability for 20 consecutive samples over ten minutes at concentrations of 100ppm equivalent or less. (After instrument stabilisation).

Limit of detection (LOD) and limit of quantification (LOQ)

  • LOD : LOQ        
  • Na – 0.0013mmol/l:   Na – 0.0043mmol/l 
  • K – 0.0005mmol/l:   K – 0.0013mmol/l 
  • Li – 0.003mmol/l :  Li – 0.0072mmol/l 

Time to Stability 

  • Less than 15 seconds after sample is introduced into the flame

Ions measured

  • Na, K, and Li

Calibration solutions provided

URINE    

Point 1                Point 2               Point 3
Na 25mmol/l     Na 50mmol/l     Na 100mmol/l
K   25mmol/l      K   50mmol/l     K   100mmol/l
Li   2.5mmol/l    Li   5mmol/l       Li   10mmol/l
Ca 2.5mmol/l     Ca 5mmol/l       Ca 10mmol/l

Point 4                 Point 5    
Na 200mmol/l    Na 300mmol/l    
K   150mmol/l    K   200mmol/l    
Li   15mmol/l     Li   20mmol/l    
Ca 15mmol/l      Ca 20mmol/l

SERUM    

Point 1                Point 2                Point 3
Na 120mmol/l   Na 130mmol/l   Na 140mmol/l
K   3mmol/l        K   4mmol/l        K   5mmol/l
Li   0.5mmol/l    Li   0.5mmol/l    Li   1mmol/l
Ca 1.5mmol/l     Ca 2mmol/l        Ca 2.5mmol/l

Point 4                Point 5    
Na 150mmol/l   Na 160mmol/l    
K   6mmol/l        K   7mmol/l    
Li   1.5mmol/l    Li   2mmol/l    
Ca  3mmol/l       Ca 3.5mmol/l

Recommended minimum warm up time based on ambient temperature

  • 21°C – 40 minutes    

Power requirements 

  • 100V – 250V AC at 50 or 60Hz

Fuel requirement 

  • Propane, Butane or Natural Gas* regulated to 19Bar. Flow rate of 0.4l/min
  • *with modifications. BWB Technologies recommends either Propane or Butane for optimum results. 

Readout

  • LCD, four line, alpha numeric, back lit.
  • USB PC Lead
  • Selection of 3 Power cables to suit all regions
  • Gas Hose
  • Propane Adapter
  • Aspiration Kit
  • Manuals covering all aspects of the BIO 943 FP 
  • Quick Start guides 
  • Warranty Registration Form 
  • Certificates of analysis for all
    provided Fluids 
  • Material Safety Data Sheets for
    all provided Fluids 
  • The FP-PC Software installation USB 
  • 1L of BWB recommended
    cleaning solution 
  • Complete set of calibration fluids including Diluent Concentrate 
  • 100ml conical flask with screw lid
  • 100 disposable sample cups 
  • 1L of De-Ionised water
  • 2m of waste tube
  • Set of spare fuses
  • 10 x 10ml pipettes 
  • 10 x 1ml pipettes